What the public permit record shows, not self-reported reviews.
Is DETECH INC a real contractor?
DETECH INC appears in public building-permit records with 3 permits filed through 2019 in and around Bellevue, WA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is DETECH INC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to DETECH INC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is DETECH INC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. DETECH INC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is DETECH INC's work?
The most recent permit on record for DETECH INC is dated 2019-01-17, with 3 permits on file in total.
Develop NICET IV construction drawings with voltage drop calcs, power supply calcs, sequence of operation matrix, functional riser diagram, device ID list, etc. then replace existing FACP and digital communicator, install new dry pipe sprinkler monitoring modules for PIV, low air supervisory and flow alarm conditions, re-configure field wiring for proper supervision, install new Notification Appliances, manual pull stations, smoke detectors, remote annunciator / control panel, radio communicator, power supplies, fire door controls, HVAC integration. Modify circuits as required. Install new dedicated 120 VAC hardwired power to FACP in conduit back to priimary power panel and modify as required (existing panel is powered by extension cord plugged into multi-port plug-strip stapled to the phone board). Install approved lock-out on new breaker.Bellevue · 2019
Develop NICET IV construction drawings with voltage drop calcs, power supply calcs, sequence of operation matrix, functional riser diagram, device ID list, etc. then replace existing FACP and digital communicator, install new dry pipe sprinkler monitoring modules for PIV, low air supervisory and flow alarm conditions, re-configure field wiring for proper supervision, install new Notification Appliances, manual pull stations, smoke detectors, remote annunciator / control panel, radio communicator, power supplies, fire door controls, HVAC integration. Modify circuits as required. Install new dedicated 120 VAC hardwired power to FACP in conduit back to priimary power panel and modify as required (existing panel is powered by extension cord plugged into multi-port plug-strip stapled to the phone board). Install approved lock-out on new breaker.Bellevue · 2019
NICET IV Design, Supply and Installation of Engineered Fire Alarm System with Intelligent FACP, sole path high supervision type cellular radio transmitter, horn/strobes in common interior areas, low frequency horns in sleeping areas, weatherproof exterior pull stations within 60' of apartment exit door openings and/or stairs, monitoring by UL listed central station, EC supervision of installation, factory / certified start-up, programming, commissioning, inspection, functional pre-testing, AHJ acceptance testing.Bellevue · 2018