Yarmouth Construction Group appears in public building-permit records with 10 permits filed through 2022 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is Yarmouth Construction Group's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to Yarmouth Construction Group by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is Yarmouth Construction Group licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. Yarmouth Construction Group has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is Yarmouth Construction Group's work?
The most recent permit on record for Yarmouth Construction Group is dated 2022-01-31, with 10 permits on file in total.
FOR THE CONSTRUCTION /ALTERATIONS THROUGHOUT AN EXISTING ATTACHED STRUCTURE TO INCLUDE STAR BOLTS AND THE REPLACEMENT OF FLOOR AND CEILING JOIST. FOR A SINGLE- FAMILY HOUSEHOLD LIVING. AS PER PLANS. *************************NO UNDERPINNING ON THIS APPLICATION. SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, MECH. OR ELECTRICAL WORK. **********************City of Philadelphia · 2022
**CONTRACTOR HAS A NOTORIZED LETTER WITH NO EMPLOYEES, SOLE WORKER**MUST UPLOAD SUB-CONTRACTOR INFORMATION IF APPLICABLE**
EZ PERMIT STANDARDS ALTERATIONS - For alterations to an Existing One Family Dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Structural alteration or repair is expressly prohibited under this permit. Prohibited structural work any modifications to exterior walls, party walls, floor/roof framing or foundations, including underpinning, excavation, and removal of foundation slab. WORK IN THE BASEMENT OR CELLAR IS NOT INCLUDED ON THE EZ ALT PERMIT. Separate permits required for Mechanical, Electric and Plumbing. Install new 1st floor kitchen cabinets, countertops and appliances, 2nd floor bathroom and bedroom partitions to be altered, all existing windows are being replaced with a U-Factor N.T.E. 0.32and no change in the size or location of the openings. No structural work and no work in the basement.City of Philadelphia · 2021
1. Upstairs Bedroom - Demo front bedroom ceiling, reframe and install new sheet rock. Demo half of the wall and reframe wall 3 feet back for newly built closet. Install vinyl floor throughout entire upstairs
2. Move Bathroom - Demo and frame new wall to expand bathroom. Run all necessary plumbing for bathroom. Install new tile floor, shower base, shower surround, sheetrock, install vanity and toilet.
3. Back Bedroom - Frame wall, move door, sheetrock
4. Stairs - Install complete Stairs from 1st to 2nd floor
interior renovation as per plan
INTERIOR RENOVATIONS AS PER PLAN
5. Doors - Install new bedroom and bathroom doors
6. Sheetrock - install sheetrock on hallway and hallway ceiling.
INTERIOR RENOVATION AS PER PLANCity of Philadelphia · 2020
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you Yarmouth Construction Group?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to Yarmouth Construction Group's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
For alterations to an Existing One Family Dwelling. No changes to the basement level. Basement to be used for mechanicals/storage only. Separate permits required for all MEP work.City of Philadelphia · 2020
Interior alteration for wall framing and replacement of all floor joist and roof rafters per engineer's plan and notes.City of Philadelphia · 2020
TO AMEND APPLICATION 1033425---DEMOLITION HAS REVEALED THAT THE EXISTING NEIGBORING STRUCTURE'S FOUNDATION, LOCATED ON THE PROPERTY LINE, IS HIGHER THAN THE BOTTOM OF THE FOOTING PROPOSED ON THE PROJECT PROPERTY THUS REQUIRING THE NEED FOR UNDERPINNINGCity of Philadelphia · 2020
FOR ALTERATIONS TO AN EXISTING 2ND FLR SPACE TO INSTALL PARTITION WALLS. CERTIFICATE OF OCCUPANCY TO BE PROVIDED IN ASSOCIATION WITH THE 2ND AND 3RD STORY. (IEBC 2018, WORK-AREA METHOD, LVL II ALTERATIONS) **SEPARATE ELECTRICAL, AND MECHANICAL PERMITS TO BE REQUIRED AS APPLICABLE.** NO WORK TO EXTERIOR WINDOWS, DOORS OR FACADES.City of Philadelphia · 2019
MAKE SAFE PERMIT - FOR REPAIR OF ALL LOOSE AND MISSING BRICKS FRONT FIRST FLOOR ABOVE DOOR AND REPAIR/REPOINT DETERIORATED AREAS ON THE SIDE WALL ABOVE FIRST & SECOND FLOOR WINDOWS NO ENGINEER'S REPORT TO RESOLVE CASE #668721. ABUTTING SIDEWALK MUST BE CLOSED WITH FENCING A MINIMUM OF 6' IN HEIGHT. SEPARATE STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CASE #668721. *CONTRACTOR HAS NO EMPLOYEES PER NOTARIZED LETTER*City of Philadelphia · 2019
EZ PERMIT STANDARDS ALTERATIONS- For alterations to an Existing One Family Dwelling as per attached standard. Deviations from this standardwill result in permit revocation and require submission of construction plans.STRUCTURAL ALTERATION OR REPAIR IS EXPRESSLY PROHIBITED UNDER THIS PERMIT. PROHIBITED STRUCTURAL WORK INCLUDES ANY MODIFICATION TO EXTERIOR WALLS, PARTY WALLS, FLOOR/ROOF FRAMING OR FOUNDATIONS; UNDERPINNING AND EXCAVATIONS (I.E. DIGGING IN BASEMENT).City of Philadelphia · 2019
MAKE SAFE PERMIT TO COMPLY WITH CASE# 628226 TO INCLUDE REPAIRS TO THE SIDE & REAR WALLS AND ROOF STRUCTURE OF AN EXIISTING STRUCTURE AND RECONSTRUCTION OF THE PARTIALLY COLLASPED PORTION OF THE FIRST FLOOR AS PLAN PER APPROVED PLANS AND PROVIDED ENGINEERING REPORT. ROOF STRUCTURE TO BE REPLACED WITH IN KIND MATERIALS. ABUTTING SIDEWALK MUST BE CLOSED WITH FENCING A MINIMUM OF 6' IN HEIGHT. SEPARATE STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CASE #628226.City of Philadelphia · 2019