What the public permit record shows, not self-reported reviews.
Is TOP GUN ENTERPRISES LLC a real contractor?
TOP GUN ENTERPRISES LLC appears in public building-permit records with 56 permits filed through 2024 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is TOP GUN ENTERPRISES LLC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to TOP GUN ENTERPRISES LLC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is TOP GUN ENTERPRISES LLC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. TOP GUN ENTERPRISES LLC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is TOP GUN ENTERPRISES LLC's work?
The most recent permit on record for TOP GUN ENTERPRISES LLC is dated 2024-04-19, with 56 permits on file in total.
FOR A LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 1ST FLOOR LEVEL OF AN EXISTING STRUCTURE. FOR USE AS A BUSINESS OCCUPANCY (BEAUTY SALON). ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. SPACE TO BE FULLY SPRINKLERED PER NFPA13. **CLASS1 STANDPIPE SYSTEM TO BE PROVIDED **ALL WORK TO BE DONE PER APPROVED PLANS. ** IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. **SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK**City of Philadelphia · 2024
FOR THE ERECTION OF AN ATTACHED BUILDING WITH A ROOF DECK AND TWO (2) ROOF DECK ACCESS STRUCTURES WITH AN ELEVATOR. FOR THE USE AS MULTI-FAMILY (63 UNITS) HOUSEHOLD LIVING AND TO INCLUDE THIRTEEN (13) ACCESSORY PARKING SPACES (INCLUDING 2 ADA ACCESSIBLE PARKING SPACES (INCLUDES 1 ADA VAN SPACE), TWO (2) AUTOSHARE PARKING SPACES) AND THIRTY (30) ACCESSORY CLASS 1A BICYCLE PARKING SPACES. BUILDING TO BE FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MEP & FP WORKS. SEPARATE APPROVAL REQUIRED FROM PA L&I FOR ELEVATOR INSTALLATION.
Amendment to include modification to foundation system along Broad and portion of Parrish Street as per approved revised plans.
Amend cellar layout to add sprinkler/ water room.City of Philadelphia · 2021
Underpinning of existing party walls only, per approved plan.City of Philadelphia · 2021
AMENDMENT 3: FOR THE AMENDMENT OF PREVIOUSLY APPROVED PERMIT CP-2020-006186 TO DOCUMENT NFPA 13 SYSTEM FOR COMMERCIAL SPACE AND NFPA 13R SYSTEM FOR A RESIDENTIAL OCCUPANCY. WORK TO INCLUDE CHANGES TO BASEMENT AND FIRST FLOOR LEVEL AS SHOWN PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.
AMENDMENT 2: FOR THE AMENDMENT OF PREVIOUSLY APPROVED PERMIT CP-2020-006186 TO DOCUMENT CHANGE IN SPECIAL INSPECTION AGENCY. ALL WORK TO BE DONE PER APPROVED DOCUMENTATION.
AMENDMENT 1: FOR THE AMENDMENT OF PREVIOUSLY APPROVED PERMIT CP-2020-006186 TO DOCUMENT CHANGE IN FOUNDATION AND FOR THE INSTALLATION OF AN EXTERIOR STAIR FROM THE BASEMENT LEVEL. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
ORIGINAL: FOR THE ERECTION OF A FOUR STORY ATTACHED STRUCTURE FOR USE AS A VACANT COMMERCIAL SPACE ON THE GROUND FLOOR IN SAME BUILDING AS 42 DWELLING UNITS (MULTIFAMILY HOUSEHOLD LIVING) WITH 14 ACCESSORY INTERIOR CLASS 1A BICYCLE PARKING SPACES. STRUCTURE TO CONTAIN A GREEN ROOF ACCESSED BY PILOT HOUSES FOR MAINTENANCE ACCESS ONLY. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND STANDPIPES TO BE PROVIDED IN THE EXIT STAIRWAYS PER NFPA 14. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. ***A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 11 FEET OF THE BUILDING FACADE IN ACCORDANCE WITH SECTION 3306 OF THE 2018 IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMIT REQUIRED PRIOR TO THE START OF ANY WORK.*** ***FIRE WATCH IS REQUIRED ONCE COMBUSTIBLE CONSTRUCTION IS OVER 40 FEET IN HEIGHT, A SITE SAFETY PLAN SHALL BE SUBMITED TO BUILDING INSPECTOR PRIOR TO THE START OF ANY CONSTRUCTION.*** SEPARATE PERMIITS TO BE OBTAINED FOR ALL OTHER WORK.
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you TOP GUN ENTERPRISES LLC?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to TOP GUN ENTERPRISES LLC's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2021
FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH PRIVATE ROOF DECK ACCESSED BY A PILOTHOUSE. FOR A VACANT COMMERCIAL SPACE AT FIRST FLOOR (SEPARATE USE PERMTI AND CO REQUIRED PRIOR TO OCCUPANCY) IN THE SAME BUILDING WITH MULTI-FAMILY HOUSEHOLD LIVING( SIX(6) DWELLING UNITS)(MIXED -INCOME ZONING BONUS (HOUSING UNIT DENSITY AS PER CODE SECTION 14-702(7)(d)(.1)) FROM SECOND FLOOR THROUGH FOURTH(4TH) FLOORS AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MEPS WORK.
*Amendment to the orriginal permit for change of first floor Business Use unit to additional R-2 Residential Unit at the rear for a total of 7 dwelling units within the new construction. And addition of mezzanine to top level units as per approved plans.City of Philadelphia · 2020
FOR WORK TO INSTALL UNDERPINNING, SOLDIER PILES AND WOOD LAGGING FOR SUPPORT OF LATERAL SOIL LOADS PER PLANS. SPECIAL INSPECTOR TO PROVIDE CONTINUOUS INSPECTIONS FOR UNDERPINNING AND PILE-DRIVING WORK. **SEPARATE STREETS DEPT PERMIT TO BE REQUIRED FOR PROPOSED WORK AND CLOSURE OF THE PUBLIC RIGHT OF WAY.**City of Philadelphia · 2020
FOR THE ERECTION OF A THREE (3) STORY STRUCTURE; FOR USE AS A TWELVE (12) FAMILY DWELLING UNIT. ENTIRE BUILDING TO BE SPRINKLERED PER NFPA 13. SEPARATE PERMIT REQUIRED FOR MEP WORK.City of Philadelphia · 2019
FOR A CERTIFICATE OF OCCUPANCY FOR A PERSONAL VEHICLE REPAIR AND MAINTENANCE WITHIN ONE (1) STORY EXISITING DETACHED STRUCUTRE. NO ALTERATION PROPOSED IN THIS PERMIT. SEPARATE PERMIT REQUIRED FOR ALL OTHER WORK.City of Philadelphia · 2019
ERECTION OF AN ATTACHED FOUR STORYSTRUCTURE FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING.(SIZE AND LOCATION AS SHOWN ON PLANS)SEE APPLICATION 942099 FOR PLANSCity of Philadelphia · 2019
ERECTION OF AN ATTACHED FOUR STORYSTRUCTURE FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING.(SIZE AND LOCATION AS SHOWN ON PLANS)SEE APPLICATION 942099 FOR PLANSCity of Philadelphia · 2019
ERECTION OF AN ATTACHED FOUR STORYSTRUCTURE FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING.(SIZE AND LOCATION AS SHOWN ON PLANS)City of Philadelphia · 2019
ERECTION OF A NEW THREE (3) STORY BUILDING, WITH BASEMENT, A ROOF DECK AND A ROOF ACCESS STRUCTURE. FOR USE AS SINGLE FAMILY HOUSEHOLD LIVING AS PER PLANS. STRUCTURE TO BE FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13D ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.City of Philadelphia · 2018
Permitted projects on public record. Addresses are omitted for privacy.