Installing four recess lights in living room, four recess lights in kitchen,five in hallway
Installing one ceiling in three bedrooms.
Installing 120 volt interconnected smoke/carbon monoxide detectors in each bedroom.living room,and hallway.
All wires will be fish thought existing walls and ceilingsCity of Philadelphia · 2026
Kitchen Reno: recep for frig, gas range, hood, 5 countertop GFI outlets, dishwasher and disposal plus LED recessed lighting (4), ceiling light. Powder room: vanity light, GFI outlet with GFCI breakers.City of Philadelphia · 2025
Electrical Permit for combo RP-2025-005251City of Philadelphia · 2025
Install one volts 120 volt circuit for fourteen led recess lights in !st floor area.
Install one 120 volt circuit for ceiling.
Install one 120 volt 20 amp circuit for two receptacles.City of Philadelphia · 2025
Replace 200 amp meter socketCity of Philadelphia · 2025
Install one new sub- panel for kitchen circuits. Install circuits for gfci counter top receptacles, Install one 220 volt circuit for range, Install circuits for dishwasher, garbage disposal and refrigerator. Install one circuit for new recess lights.City of Philadelphia · 2025
TEST AND RECONNECT EXISTING SMOKE DETECTORS, PULL STATIONS, HORNS AND STROBES. REPLACE SMOKE DETECTORS, PULL STATIONS, HORNS AND STROBES ACCORDING TO THE 2017 NEC.
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2024
Replace and up grading existing 100 amp 16 circuit service panel with new 100 amp 22 circuit service panel and install all existing circuit into new 100 amp service panel. Service panel is surface mount and is located in unfinished part of basement on concrete wallCity of Philadelphia · 2024
Amend Permit 12/4/2024 - Install new 200 amp service with new meter socket, new 4/0 service cable, 40 circuit, 200 amp main panel, #4 grounded conductor and ground rods. Install new AFCI/GFCI protected in metal conduit for receptacles in basement rec-room, one afci protected circuit for 7 recess lights to be control by new 3-way circuit in open beam ceiling. Ceiling will remain open and no sheet rock will be installed. Install one 20 gfci 120v circuit for bathroom to one receptacle, one exhaust fan and one vanity light. Install one 220v 60A in open ceiling for one 4-prong surface mount receptacle range in kitchen, install one motion light at top of basement staircase. Remove one existing recep from lv. rm. area
Electrical Permit for combo RP-2024-006549City of Philadelphia · 2024
Installing new receptacles and lighting on all floors and Installing new 200 amp service
AS PER NEC 2017City of Philadelphia · 2024
Install new circuits for receptacles and lighting on first floor.
Install new circuits for receptacles and lighting on second floor
Install afci and gfci protection on circuits
Install one 220 volt circuit for central air unit.
AS PER NEC 2017City of Philadelphia · 2024
Wiring of in ground pool equipment with 60 amp main feed, sub panel installed at equipment, with one circuit for one gfci receptacle,one pump motor,one pool heater as per 2017 necCity of Philadelphia · 2023