What the public permit record shows, not self-reported reviews.
Is STEVEN PITTAOULIS a real contractor?
STEVEN PITTAOULIS appears in public building-permit records with 91 permits filed through 2026 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is STEVEN PITTAOULIS's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to STEVEN PITTAOULIS by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is STEVEN PITTAOULIS licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. STEVEN PITTAOULIS has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is STEVEN PITTAOULIS's work?
The most recent permit on record for STEVEN PITTAOULIS is dated 2026-03-27, with 91 permits on file in total.
Furnish and install all Labor & Material for the following scope of work:
Kitchen:
- Reuse some existing circuits and possibly extend them to feed GFCI protected countertop receptacles, dishwasher, Garbage Disposal, 240 Volt Range, refrigerator, and (2) GFCI protected island receptacles.
- New wiring for (9) recessed LED lights on 3 way dimmable, (3) pendants over the island and (1) over furnished chandelier over table, controlled by separate dimmers.
- New wiring, transformer, ~10 feet of LED under-counter tape lighting, and dimmer
- New arc fault breakers for all extended existing circuits and new.
Living Room:
- Existing receptacle locations to remain. Reuse existing circuits and run new wiring for (6) LED recessed lights & (1) flush mount ceiling light controlled by (2) 3 way dimmable switches. New wiring, outlet boxes, and hang (4) owner furnished wall sconces controlled by (1) dimmer switch.
- New wiring, outlet boxes, receptacles for Record player, TV, and Gas Fireplace insert.
- New wiring, switch and (2) owner furnished outside light fixtures
2nd Floor Bedroom:
- Existing receptacle locations to remain. Reuse existing circuits and run New wiring & dimmer switch for (4) Recessed LED lights
- New wiring & dimmer switch for (1) owner furnished ceiling light
- New wiring & regular switch for (2) recessed LED lights in closet
- New Smoke detector
3rd Floor Bath:
- Existing receptacle locations to remain. Reuse existing circuits and run new wiring, (2) switches, (4) dimmers (5) Recessed LED lights, (2) owner furnished vanity lights, (1) owner furnished ceiling light over tub, (2) exhaust fans, (2) countertop GFCI protected receptacles, and (1) GFCI receptacle behind Water Closet.
3rd Floor Office:
- Existing receptacle locations to remain. Reuse existing circuits and run new wiring, (1) dimmer & (4) recessed lights
3rd Floor Bedroom:
- New wiring, (3) dimmers, (4) LED recessed lights, (2) owner furnished ceiling fixtures above Fireplace, (1) Owner furnished cCity of Philadelphia · 2026
Connect wall sign to existing electric
GP-2026-001210City of Philadelphia · 2026
Provide complete wiring throughout, including lighting fixtures, switches, exit signs, emergency lighting, receptacle outlets, sprinkler tamper switch and waterflow switch connections. Install interconnected smoke and carbon monoxide alarms and a complete fire alarm system. All work to be done according to the 2017 NEC, 2016 NFPA 72 and per approved plans.
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you STEVEN PITTAOULIS?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to STEVEN PITTAOULIS's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2026
Replace in Kind the Service: New 200-amp service, new double meter socket with outdoor breakers/disconnect, and new grounding electrode system
Replace in Kind switches, receptacles, and light fixtures, Emergency exit and egress lighting, Smoke detectors, smoke/carbon detectors
Remove all visible knob and tube wiring and refeed by means of fishing.
Remove and replace (2) existing panels with (2) new 100 amp panels in basement
Replace in kind light fixtures (supplied by property owner)City of Philadelphia · 2026
New cable by means of fishing to the 2nd floor for new lighting and receptacles for 2 rooms.City of Philadelphia · 2026
- Remove, bore new holes, and rerun existing circuits through new joists into existing Electrical panel in basement
- Secure cablesCity of Philadelphia · 2026
Furnish and install all Labor & Material with some Demo of 2nd Floor potential knob & tube wiring, reuse some good circuits and pull new cabling for the following areas and scope:
Primary Bedroom:
- (6) Receptacles, (4) Recessed lights, (1) ceiling fan, (2) motion closet lights, (1) dimmer and (1) switch, (1) smoke detector
Bedroom #1:
- (4) Receptacles, (4) Recessed lights, (1) owner furnished ceiling fixture, (2) dimmers, (1) smoke detector
Bedroom #2:
- (4) Receptacles, (4) Recessed lights, (1) owner furnished ceiling fixture, (2) dimmers, (1) smoke detector,
Hallway:
- (1) owner furnished wall sconce, (2) 3 way switches, (1) 4 way switch, (1) combo carbon/smoke detector, and (1) receptacle
- Power for Mini Split, disconnect, etc.
Bathroom:
- (1) GFCI Receptacle center of (2) vanity sinks, (2) Recessed lights, (2) owner furnished vanity fixtures, (2) dimmers, (1) Exhaust fan and (1) standard switch.
- Circuit and installation of switch for GC provided Floor heat
(4) 15 amp Arc fault circuits for Lighting & receptacles
(1) 20 amp circuit for Bathroom GFCI
(1) 20 amp 120 Volt circuit for floor heat
(1) 30 amp 240 Volt circuit for Mini Split.City of Philadelphia · 2025
New 300 Amp Service, 3 gang meter socket, new 125 amp main breaker disconnect for Apartment, 60 amp main breaker panel for House, NOTE: Excluding 200 amp Commercial Space.
- New wiring for Fire Alarm System throughout Apartment common area and Commercial space, and Fire Alarm Panel in Basement by House Panel,
- Apartment Rewire all new per NEC 2018, with 120 Volt smokes, electric appliances (WH, Range, AC, etc), receptacles, switches, and arc fault breakers.City of Philadelphia · 2025
Fishing of (5) new 15 amp circuits to replace knob & tube. Removal and reinstallation of existing light fixtures after new cables are fished and outlet boxes installed.
Fish New MC cable and install (12) new recessed lights.
Replace in kind a 200 amp main breaker panel with new
Replace in kind a 100 amp subpanel with new
Replace in kind a 30 amp subpanel with newCity of Philadelphia · 2025
Tenant improvement to replace fixtures using existing circuits. There are no new circuits being installed. The lighting is also being replaced as it was before.
*** NO FIRE ALARM ON THIS PERMIT***City of Philadelphia · 2025
New wiring per NEC 2017, less than 2000 sq ft home, with new arc fault breakers, outlet boxes, lighting, kitchen circuits, appliance circuits, laundry circuit and circuits for HVAC.City of Philadelphia · 2025
Install 3 800KCMIL AL SERVICE CONDUCTORS , 4 gang meter socket with service disconnects, proper grounding and bonding of Service, Subpanels in each apartment. All interior wiring with Romex concealed in walls for Receptacles, Lighting, Switches, and hardwired smoke alarms in each unit with Arc Fault breakers, 2 appliance circuits, microwave, fridge, dishwasher, garbage disposal, washer, dryer, AC, gas range, Gas Water Heater. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.
**SEPARATE FIRE ALARM PERMIT REQ'D**City of Philadelphia · 2025
Permitted projects on public record. Addresses are omitted for privacy.