What the public permit record shows, not self-reported reviews.
Is SIGNORA ELECTRIC COMPANY INC a real contractor?
SIGNORA ELECTRIC COMPANY INC appears in public building-permit records with 87 permits filed through 2026 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is SIGNORA ELECTRIC COMPANY INC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to SIGNORA ELECTRIC COMPANY INC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is SIGNORA ELECTRIC COMPANY INC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. SIGNORA ELECTRIC COMPANY INC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is SIGNORA ELECTRIC COMPANY INC's work?
The most recent permit on record for SIGNORA ELECTRIC COMPANY INC is dated 2026-02-10, with 87 permits on file in total.
*** NO FIRE ALARM ON THIS PERMIT***
Utilize existing power for new workstations.
- Reconfigure and extend existing circuits to feed new workstations.
- Provide and install additional circuits required for new seating area.
Provide and install additional circuit for the overbridge
Per plansCity of Philadelphia · 2026
Provide and install 2 new dedicated circuits for as per drawings dated 11-12-2025.
- Relocate existing receptacles and data as per plans dated 9-30-2025.
- Provide and install (4) new flush floor boxes for quad outlets.
- Provide and install Cat6 wiring and terminations for (2) new Data locations as per drawings dated 11-12-2025.
Installation shall comply with 2017 NEC.City of Philadelphia · 2026
• Disconnect and remove existing electrical devices as per demo drawings.
• Provide and install branch wiring for all electrical receptacles, devices and equipment.
• Existing lighting to be rewired as per drawings.
• Provide and install all light fixtures as per electrical drawings.
• Disconnect and remove smoke detectors. PER APPROVED DRAWINGS-2017 NEC.City of Philadelphia · 2026
INSTALL WIRING, LIGHTING, LIGHTING CONTROLS, EXIT SIGNS, EMERGENCY LIGHTING AND RECEPTACLE OUTLETS. INSTALL DEDICATED BRANCH CIRCUITS FOR EQUIPMENT AND APPLIANCES. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND PER PLANS.City of Philadelphia · 2025
Relocate existing electrical panels and feeders. Install receptacles, lighting, and tele/data wiring as per 2017 NEC. Install fire alarm system as per 2016 NFPA 72.City of Philadelphia · 2025
INSTALL DEDICATED BRANCH CIRCUITS FOR THE COPIERS, 2 CARD READERS FOR THE DOORS AND PULL STRINGS FOR DATA AT NEW DESK ROOM.
ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND PER PLANS.
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you SIGNORA ELECTRIC COMPANY INC?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to SIGNORA ELECTRIC COMPANY INC's website. It links to this profile so homeowners can see the public permit record behind your work.
- Provide Electrical engineered drawings for permit.
- Provide and install (1) 45kva 480v to 208v transformer in Storage room.
- Provide and install (1) new 150amp electrical panel in space with shunt trip breakers for equipment under hood.
- Provide and install new electrical feeder from Concourse electrical MDP.
- Provide and install (3) feeders to (3) new machines.
- Installation shall comply with 2017 NEC.
- Relocate Fire alarm pull station as per 2016 NFPA72.City of Philadelphia · 2025
- Demo existing Lighting and equipment as per plans.
- Provide and install new lighting as per plans.
- Relocate existing panels and meters as per plans.
- Provide and install new 150A feeder from B1.5 electrical panel as per base bid. Provide (1) month of peak
metering of panel and provide readings to owner.
- Provide and install (2) new electrical panels and (1) 9kva transformer.
- Provide engineered short circuit, coordination, and arc flash study for (2) new panels. Study will be
based on information provided from current building study.
- Provide and install conduits and wiring for power to all equipment as per plans.
- Provide and install conduit for BAS wiring.
- All work is to be performed during normal hours except where needed due to noise or work in the
garage area.
- Starters and VFD’s for mechanical equipment to be provided by others.
- All wiring to be installed in EMT conduit
- Installation shall comply with 2017 NEC
- Provide and install fire alarm devices, system, and programming as per Red Hawk proposal and 2016 NFPA 72.City of Philadelphia · 2024
RELOCATE THE EXISTING PANELS, FEEDERS & BRANCH WIRING. INSTALL (6) NEW LOAD CENTERS, FUSED DISCONNECT & FEEDERS. INSTALL WIRING THROUGHOUT THE COMMON AREAS, SUITES ,DWELLING UNITS & TERRACE AREA. INSTALL LIGHTS, SWITCHES, SENSORS & LIGHTING CONTROLS. INSTALL RECEPTACLES , FLOOR RECEPTACLES & SMOKE ALARMS. PROVIDE POWER FOR THE MECHANICAL & HVAC EQUIPMENT. INSTALL ADDITIONAL FIRE ALARM DEVICES ON THE EXISTING FIRE ALARM SYSTEM. ALL WORK IN ACCORDANCE WITH THE 2017 NEC.City of Philadelphia · 2024
• Provide and install conduit and wire from existing panel to new AHU.
• Install new VFD that is provided by others.
• Provide and install new 60 Amp breaker.City of Philadelphia · 2024
REMOVING OF EXISTING SMOKE DETECTORS THAT ARE NOT REQUIRED AS PER 2016 NFPA 72.City of Philadelphia · 2024
Electrical Permit for combo CP-2024-000990City of Philadelphia · 2024
Permitted projects on public record. Addresses are omitted for privacy.