What the public permit record shows, not self-reported reviews.
Is Safe-Route Electric, Inc a real contractor?
Safe-Route Electric, Inc appears in public building-permit records with 66 permits filed through 2024 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is Safe-Route Electric, Inc's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to Safe-Route Electric, Inc by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is Safe-Route Electric, Inc licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. Safe-Route Electric, Inc has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is Safe-Route Electric, Inc's work?
The most recent permit on record for Safe-Route Electric, Inc is dated 2024-09-26, with 66 permits on file in total.
Demo incoming electric service
Install new 200 amp incoming service
Install (30) new receptacles
Install (15) new switches
Install new recessed lights
Install new wiring throughout
Install GFCI receptacles where requiredCity of Philadelphia · 2024
INSTALL 100 AMP ELECTRICAL SERVICE WITH MAIN CIRCUIT BREAKER PANEL. REWIRE HOUSE THROUGHOUT AND INSTALL LIGHTING, RECEPTACLES OUTLETS. INSTALL SMOKE CO ALARMS ACCORDING TO THE 2017 NEC. (FISHING WIRING)City of Philadelphia · 2024
Replace incoming 100 amp service
install (1) carbon/smoke detector
Install (2) dedicated GFCI receptacles and circuits
Install (3) LED light fixtures in basement
Install (2) 10 year battery smoke detectors
replace (10) receptacles
replace (7) switches
All wiring is to be fished through existing wallsCity of Philadelphia · 2024
Replace incoming 100amp service
Install (1) carbon/smoke detector
Install (2) dedicated ground fault receptacles and circuits
Install (2) 10 year battery smoke detectors
All wiring is to be fished through existing walls
AS PER NEC 2017City of Philadelphia · 2024
Replace incoming 100 amp service
Install (3) GFCI receptacles and circuits
Install (3) GFCI receptacles
Install (2) 10 year battery smoke detectors
Install (1) 10 year battery carbon/smoke detector
Install (1) wall light fixture
Replace (1) bathroom exhaust fan
Replace (4) ceiling light fixtures
Replace (10) receptacles
Replace (10) switches
All wiring is to be fished through existing wallsCity of Philadelphia · 2024
Replace incoming 100 amp service
Install (2) GFCI receptacles and circuits
Install (3) basement LED light fixtures
Install (2) 10 year battery smoke detectors
Install (1) 10 year battery carbon/smoke detector
Replace (8) receptacles
Replace (8) switches
All wiring is to be fished through existing walls
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you Safe-Route Electric, Inc?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to Safe-Route Electric, Inc's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2024
100 AMP SERVICE AND PANEL - 32 SPACE PANEL (10)
NSTALL SMOKE/CARBON MONOXIDE DETECTOR, 10 YEAR
BATTERY (3)
REPLACE RECEPTACLE 15/20 AMP (10)
INSTALL FLUSH MOUNT LED CEILING FIXTURE (BASEMENT) (3)
UNDERWRITER INSPECTION (1)
PERMIT (1)
GROUND FAULT RECEPTACLE (1)
100 AMP SERVICE AND PANEL - 32 SPACE PANEL (1)
All wire is to be fished thru existing walls
AS PER NEC 2017City of Philadelphia · 2024
Replace incoming 100 amp service
Install (3) dedicated ground fault receptacles and circuits
Install (2) 10 year battery smoke detectors
Install (1) 10 year battery carbon/smoke detector
Troubleshoot and repair bedroom light
Install (4) new receptacles and circuits
Replace (1) exterior light fixture
all wiring is to be fished through existing wallsCity of Philadelphia · 2024
Replace incoming 100 amp service
Install (2) ground fault receptacles
Install (2) 10 year battery smoke detectors
Install (1) 10 year battery carbon/smoke detector
Install (1) 20 amp receptacle and circuit
Replace (6) receptacles
All wiring is to be fished through existing walls
AS PER NEC 2017City of Philadelphia · 2024
Replace incoming 100 amp service
Replace (2) 3-way switches
Install (3) arc fault breakers
Install (6) ground fault receptacles
Install (2) ground fault receptacles and circuits
Install (2) 10 year battery smoke detectors
Install (1) carbon/smoke detector
Evaluate blinking light fixture
Install (4) new receptacles and circuits
Replace exterior light fixture
Replace hallway light fixture
Replace (12) receptacles
Replace (1) single pole switch
All wiring is to be fished through existing walls
AS PER NEC 2017City of Philadelphia · 2024
Replace incoming 100 amp service
Install (1) GFCI receptacle
Install (2) 10 year battery smoke detectors
Install (1) carbon/smoke detector
Replace (1) receptacle
All wiring is to be fished through existing walls
AS PER NEC 2017City of Philadelphia · 2023
Replace incoming 100 amp service
Install (1) carbon/smoke detector
Install (2) 10 year battery smoke detectors
Install (2) porcelain fixtures
Redistribute (3) overloaded circuits
Replace (10) switches
All wiring is to be fished through existing walls
AS PER NEC 2017City of Philadelphia · 2023