Install New 400 amp service installation and wiring throughout,lighting receptacles, fire alarm. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.City of Philadelphia · 2023
Install new electrical service ,lighting, receptacles,low voltage wiring ,equipment . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.
AMENDMENT: INSTALL FIRE ALARM.City of Philadelphia · 2023
INSTALL A 300 KW GENERATOR, 800 AMP FEEDER FROM THE GENERATOR TO THE TROUGH, INSTALL A 200 AMP FEEDER TO THE EXISTING 200 AMP FUSED DISCONNECT SWITCH, INSTALL A 400 AMP FEEDER TO THE EXISTING 400 AMP FUSED DISCONNECT SWITCH. INSTALL A 200 AMP FEEDER FROM THE GENERATOR TO THE EXISTING FIRE PUMP TRANSFER SWITCH, INSTALL A 200 AMP SERVICE TO THE NEW 200 AMP FIRE PUMP SERVICE DISCONNECT SWITCH. ALL WORK IN ACCORDANCE WITH THE 2017 NEC.City of Philadelphia · 2023
Remove existing light fixtures, switches and receptacles. Install new light fixtures and switches, and connect to existing circuits as per 2017 necCity of Philadelphia · 2023
INSTALL (2) SINGLE CATEGORY 6 CABLE LOCATIONS, (17) DUAL CATEGORY 6 CABLE LOCATIONS, INSTALL A 24"X 19" SWING MOUNT RACK EQUIPPED WITH (1) 48 PORT PANEL, INSTALL J-HOOKS ABOVE CEILING FOR CABLE PATHWAYSCity of Philadelphia · 2022
INSTALL A 250KW / 480V / 277V THREE PHASE GENERATOR, 400 AMP SERVICE RATED TRANSFER SWITCH AND 400 AMP PANEL AND FEEDER. ALL WORK IN ACCORDANCE WITH 2017 NEC.City of Philadelphia · 2022
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
Category 6A data cable refresh in an interior floor of an office building ? labor and consumable materials only as per 2017 necCity of Philadelphia · 2022
INSTALLA 250 KW /480V/277V THREE PHASE GENERATOR, 400 AMP SERVICE RATED TRANSFER SWITCH AND A 400 AMP PANEL & FEEDER.
ALL WORK IN ACCORDANCE WITH THE 2017 NEC.City of Philadelphia · 2021
Installation of all interior wiring and dwelling is less than 2,000 square feet. AS PER NEC 2014City of Philadelphia · 2021
Riley Electric will provide LABOR ONLY to install the following customer provided materials:
Install J-Hooks and Pull Lines for new pathways renovation space.
Install Twenty-Five (25) Single Category 6 cable locations for workstation, TVs and Wireless Access Points. Each location will be terminated with a Category 6 RJ45 type jack and Faceplate/Surface box. All cabling to be pulled back to the IDF.
Install Five (5) Single Category 6 cable locations for cameras. Each location will be terminated with a Category 6 RJ45 type jack with a single port surface box above ceiling.
Install one (1) Category 6 patch panels 48 port each on rack in ID.
Test and label all cable locations
As per 2017 NECCity of Philadelphia · 2021
Riley Electric is providing labor only to install a new 100 amp electrical service as per 2014 necCity of Philadelphia · 2021
Riley Electric will be providing labor only for the following work:
Install j-hook cable supports in the branch ceiling.
Install two four-inch pass-through sleeves for cable migration into the IT room.
Install Category 6 cables (grey) for 15 workstations and one AP location, according to the provided print.
Install a wall-mount data rack and 48-port Category 6 patch panel in the IT Room.
Ground a data rack to the provided bus bar in IT Room.
Terminate cables on the patch panel and extend the provided demark circuits in the IT Room to the patch panel.
Terminate the stations with Category 6 grey jacks and white faceplates.
Test and label all Category 6 cabling.
As per 2017 NECCity of Philadelphia · 2021