What the public permit record shows, not self-reported reviews.
Is REVISE a real contractor?
REVISE appears in public building-permit records with 35 permits filed through 2023 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is REVISE's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to REVISE by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is REVISE licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. REVISE has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is REVISE's work?
The most recent permit on record for REVISE is dated 2023-02-06, with 35 permits on file in total.
FOR INTERIOR ALTERATION AND THE ERECTION OF AN ADDITION AS PART OF AN EXISTING ATTACHED STRUCTURE TO INCLUDE THE LEGALIZATION OF A DECK AT THE REAR TO CONTINUOUS USE AS SINGLE-FAMILY DWELLING. THE EXISTING BASEMENT TO REMAIN NON-HABITABLE SPACE. SIZE AND LOCATION AS SHOWN ON THE PLANS.
** SEPARATE PERMIT REQUIRE FOR ELECTRICAL, PLUMBING AND MECHANICAL **City of Philadelphia · 2023
EZ PERMIT STANDARDS ALTERATIONS
For alterations to an Existing One Family Dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. STRUCTURAL ALTERATION OR REPAIR IS EXPRESSLY PROHIBITED UNDER THIS PERMIT. PROHIBITED STRUCTURAL WORK INCLUDES ANY MODIFICATION TO EXTERIOR WALLS, PARTY WALLS, FLOOR/ROOF FRAMING OR FOUNDATIONS; UNDERPINNING AND EXCAVATIONS (I.E. DIGGING IN BASEMENT). ANY WORK/ALTERATIONS TO THE BASEMENT/CELLAR IS EXPRESSLY PROHIBITED UNLESS DOCUMENTED AS AN EXISTING HABITABLE SPACE WITH HEIGHTS AND MEANS OF EGRESS PER CONDITIONS OF THE EZ STANDARD. Separate permits required for Mechanical, Electric and Plumbing, ETC.
No work in basement.
Remove 1st floor coat closet.
Frame new GWB partitions at 1st floor to create 2 piece powder room- with new fixtures with piping, install vent at bathroom.
New electrical wiring for powder room.
Replace light fixtures throughout house.
Install new kitchen cabinets and countertop at 1st floor kitchen.
Install new front and back doors. (All existing windows to remain.)
Install new floor coverings throughout house, 1st and 2nd floors with new baseboard trim.
Paint all walls.
Replace all interior doors.
Replace fixtures in 2nd floor existing bathroom (new toilet, vanity/sink and bathtub), use existing piping.
Replace tile at 2nd floor bathroom- floor and shower surround.
Property is not owner occupied or owned by an LLC- see licensed PA engineering letter. stating no structural work is to be done.City of Philadelphia · 2021
FOR THE CONSTRUCTION /ALTERATIONS THROUGHOUT AN EXISTING ATTACHED STRUCTURE. FOR A SINGLE- FAMILY HOUSEHOLD LIVING. AS PER PLANS. *************************NO UNDERPINNING ON THIS APPLICATION. SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, MECH. OR ELECTRICAL WORK.*****City of Philadelphia · 2021
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you REVISE?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
EZ PERMIT STANDARDS ALTERATIONS - For alterations to an Existing One Family Dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Structural alteration or repair is expressly prohibited under this permit. Prohibited structural work any modifications to exterior walls, party walls, floor/roof framing or foundations, including underpinning, excavation, and removal of foundation slab. WORK IN THE BASEMENT OR CELLAR IS NOT INCLUDED ON THE EZ ALT PERMIT. Install three piece bathroom within an existing walk-in closet, install bar sink at kitchen PER Engineer's letter.City of Philadelphia · 2021
EZ PERMIT STANDARDS ALTERATIONS - For alterations to an Existing One Family Dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Structural alteration or repair is expressly prohibited under this permit. Prohibited structural work any modifications to exterior walls, party walls, floor/roof framing or foundations, including underpinning, excavation, and removal of foundation slab. WORK IN THE BASEMENT OR CELLAR IS NOT INCLUDED ON THE EZ ALT PERMIT. Separate permits required for Mechanical, Electric and Plumbing. Replace kitchen cabinets, replace tile and fixtures and finishes in bathroom, Separate permits required for HVAC & Electric.City of Philadelphia · 2021
4th floor addition to existing three-story buildingCity of Philadelphia · 2021
amend ap# 1051437 to include structural repair of foundation and install star bolts ( no changes to building size and height)City of Philadelphia · 2020
MAKE SAFE MAKE SAFE PERMIT - FOR THE REMOVAL OF THE COLLAPSED 1ST FLOOR REAR SHED TO RESOLVE CASE #577164. ABUTTING SIDEWALK MUST BE CLOSED WITH FENCING A MINIMUM OF 6' IN HEIGHT. SEPARATE STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CASE #577164. -DEMOLISH SHED ON REAR WALL OF THE PROPERTY IN ORDER TO MAKE SAFE AND CLEAR THE WAY FOR THE CONSTRUCTION OF A NEW SHED /KITCHEN ON THE SAME FOOTPRINT.City of Philadelphia · 2019
LEVEL 1 ALTERATION: To include the removal and replacement or the covering of existing materials, elements, equipment or fixtures using new materials, elements, equipment or fixtures that serve the same purpose. *NO STRUCTURAL WORK ,INSTALLATION OF NEW WALLS AND NO PENETRATIONS TO FIRE RATED ASSEMBLIES*City of Philadelphia · 2019
AMEND PERMIT #887864 TO CHANGE FOUNDATION FROM POURED CONCRETE TO CMU FULLY GROUTED SOLIDCity of Philadelphia · 2019
TO REINSTATE PERMIT #761126: REMOVE EXISTING ONE STORY REAR SHED ADDITON,2ND FLOOR BATHROOM, CONSTRUCTION OF NEW BATHROOM AT 2ND FLOOR LEVEL, INFILL EXTERIOR WALLS AND KITCHEN RENOVATIONS PER SUBMITTED PLAN.(PLANS UNDER PERMIT #761126)City of Philadelphia · 2019
RENOVATIONS TO AN EXISTING, THREE (3) STORY SINGLE FAMILY DWELLING. SEPERATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBINGCity of Philadelphia · 2019
Permitted projects on public record. Addresses are omitted for privacy.