What the public permit record shows, not self-reported reviews.
Is REED ST BUILDERS LLC a real contractor?
REED ST BUILDERS LLC appears in public building-permit records with 141 permits filed through 2026 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is REED ST BUILDERS LLC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to REED ST BUILDERS LLC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is REED ST BUILDERS LLC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. REED ST BUILDERS LLC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is REED ST BUILDERS LLC's work?
The most recent permit on record for REED ST BUILDERS LLC is dated 2026-01-23, with 141 permits on file in total.
FOR LEVEL II ALTERATIONS TO INCLUDE NEW PARTITIONS, FIXTURES, FURNISHINGS, FINISHES, DOORS, STRUCTURAL WORK AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK. *2018 IEBC*City of Philadelphia · 2026
FOR THE REMOVAL AND REPLACEMENT OF THE BASEMENT SLAB AND INSTALLATION OF AN EMERGENCY ESCAPE AND RESCUE OPENING IN AN EXISTING ATTACHED STRUCTURE USED AS A SINGLE-FAMILY DWELLING AS PER BUILDING APPLICATION/PLAN. NO UNDERPINNING INCLUDED. A SEPARATE EXCAVATION PERMIT IS ASSOCIATED WITH THIS PERMIT. A SEPARATE PERMIT REQUIRED FOR ANY SCOPE OF WORK BEYOND THE APPROVED PLANS.City of Philadelphia · 2025
For the ereation of a new construction for use as two vacant commercial/retail spaces at the first floor (Separate use registration and CO required prior to occupancy) and (157) residential dwelling units at the second through seventh floors, with accessory amenity spaces, accessory parking, and a roof deck as per approved plans. Building to be fully sprinklered. Separate permits required for MEP & FP work. Separate approval required from PA L & I for elevator installation.
AMENDMENT#1 TO CHANGE FLOOR LAYOUT AND ELEVATION WITH ASSOCIATED STRUCTURAL DESIGN AS PER APPROVED AMENDED PLANS WITH CHANGE OF THE DPRC-SI AND SPECIAL INSPECTION AGENCY.City of Philadelphia · 2025
FOR LEVEL II ALTERATIONS AND ADDITION OF MEZZANINE PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUBMING AND FIRE SUPPRESSION WORK. *REFERENCE BUILDING PERMIT CP-2024-002997 FOR ALTERATIONS WITHIN SAME TENANT SPACE*City of Philadelphia · 2024
FOR THE INSTALLATION OF TWO (2) STAR BOLTS STITCH-TIES TO AN EXISTING TWO-STORY ATTACHED SINGLE-FAMILY DWELLING AS PER APPROVED PLAN.City of Philadelphia · 2024
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you REED ST BUILDERS LLC?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to REED ST BUILDERS LLC's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
FOR LEVEL II ALTERATIONS TO AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE TWO MASONRY OPENINGS THROUGH EXISTING WALL SUPPORTED BY CONCRETE FOUNDATION. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS.
***************** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ******************************************City of Philadelphia · 2024
LEVEL III ALTERATIONS WITH COMPLETE CHANGE OF OCCUPANCY TO CREATE A CHILD CARE CENTER AND EDUCATIONAL FACILITY WITHIN AN EXISTING ONE-STORY WITH BASEMENT BUILDING AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED. *2018 IEBC REVIEW*
**SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**
*AMENDMENT 10/7/24 TO INCLUDE NEW & MODIFIED FIXTURES, NEW DOORS, PARTITIONS.
*AMENDMENT 2/12/25 TO REPLACE ELEVATOR WITH PLATFORM LIFT.City of Philadelphia · 2024
FOR LEVEL II ALTERATIONS (NO CHANGE IN OCCUPANCY) PER APPROVED PLANS AT GROUND FLOOR AND BASEMENT. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION.
*AMEND 2/21/2025 - REVISED FLOOR PLAN PER AMENDED CONSTRUCTION DOCUMENTS*City of Philadelphia · 2024
LEVEL II INTERIOR ALTERATIONS WITH PARTIAL CHANGE OF OCCUPANCY TO FIT-OUT SHELL 2ND FLOOR SPACE FOR SIXTEEN (16) ADDITIONAL DWELLING UNITS [FOUR HUNDRED TWENTY-SIX (426) TOTAL DWELLING UNITS IN BUILDING] AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IBC REVIEW*
**SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**
AMENDMENT APPROVED 5/4/24
AMEND ALTERATIONS PERMIT CP-2023-006457 TO INCLUDE CHANGES TO LAYOUTS AND WALL TYPES AS PER APPROVED PLANS.City of Philadelphia · 2024
Interior Alteration to include: modifications to existing stair guard rails, addition of water closet on 1st floor, modifications to kitchen cabinet layout, modification to exterior door exiting to backyard, and modification to lighting throughout interior spaces. details as shown on plan.City of Philadelphia · 2023
FOR THE REINFORCEMENT OF AN EXISTING DECK. **STRUCTURAL ALTERATION TO BE INCLUDED ** EXTERIOR WORK ONLY**City of Philadelphia · 2023
AMENDMENT IV: FOR THE AMENDMENT OF PREVIOUSLY APPROVED PERMIT #CP-2022-004517 TO DOCUMENT CHANGE IN DPRC-SI
AMENDMENT III: FOR THE AMENDMENT OF PREVIOUSLY APPROVED PERMIT #CP-2022-004517 TO DOCUMENT PARTIAL CHANGE TO EXTERIOR FINISH AS SHOWN PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
AMENDMENT II: FOR THE AMENDMENT OF PREVIOUSLY APPROVED PERMIT #CP-2022-004517 TO DOCUMENT STRUCTURAL CHANGES TO STRUCTURE, TO INCLUDE THE FOLLOWING: FRAMING, FOUNDATION WORK INVOLVING UNDERPINNING AND SHORING. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.
AMENDMENT: FOR THE AMENDMENT OF PREVIOUSLY APPROVED PERMIT #CP-2022-004517 TO DOCUMENT CHANGE IN INTERIOR LAYOUT IN SEVERAL AREAS THROUGHOUT THE BUILDING WITH MINOR CHANGES TO STRUCTURAL COMPONENTS AS SHOWN PER APPROVED PLANS SEALED BY STRUCTURAL ENGINEER. ALL WORK TO BE DONE PER APPROVED PLANS AND DOCUMENTATION.
ORIGINAL: FOR THE ERECTION OF AN ATTACHED FIVE STORY STRUCTURE TO INCLUDE ROOF DECK, ROOFTOP ACCESS STRUCTURES, AND GREEN ROOF INSTALLATION. THE APPLICANT MUST EXECUTE AND RECORD A DEED RESTRICTION PRIOR TO ISSUE CERTIFICATE OF OCCUPANCY IN FAVOR OF THE CITY. STRUCTURE FOR USE AS 107 HOUSEHOLD LIVING UNITS, TO INCLUDE VACANT GROUD FLOOR AND SECOND FLOOR COMMERCIAL SPACES AND THIRTY-EIGHT (38) ACCESSORY BICYCLE PARKING SPACES. SEPARATE USE PERMIT REQUIRED FOR VACANT COMMERCIAL SPACES. STRUCTURE COMPOSED OF TWO DIFFERENT CONSTRUCTION TYPES: TYPE 1A CONSTRUCTION FOR THE FIRST FLOOR LEVEL, WITH TYPE IIIA CONSTRUCTION FROM THE SECOND THROUGH FIFTH FLOOR LEVEL. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND STANDPIPES TO BE PROVIDED IN THE EXIT STAIRWAYS PER NFPA 14. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. **A COVERED WALKWAY OR SIDEWALK CLCity of Philadelphia · 2022