RENOVATED LAB SPACE. 1 NEW 100A PANEL, 3 NEW LIGHT FIXTURES, 5 NEW FLOOR BOXES, 4 NEW GFIS 39 DUPLEX OUTLETS, 2 NEW FIRE ALARM DEVICES. FIRE ALARM DRAWINGS WITH VOLTAGE DROP AND BATTERY CALCS WILL BE ADDED TO THIS ONCE RECEIVED FROM THE FA VENDOR, AS PER 2017 NEC (WEST DIST)City of Philadelphia · 2019
BASEMENT MECHANICAL UPGRADE. 1NEW 400A 120/208V 3PH-4W PANEL FED FORM EXISTING PANEL. 29 NEW LIGHT FIXTURES, 15 MECHANICAL CONNECTIONS , 10 GFI RECEPTACLES AND 1 QUAD OUTLET. THERE ARE 6 DRAWINGSCity of Philadelphia · 2019
INSTALL 1-NEW 800AMP LOAD BANK WITH INSTALL OF CONDUIT AND DISCONNECT SWITCH FROM NEW LOAD BANK UNIT TO EXISTING 2ND FLOOR BUILDING GENERATOR AS PER 2008 NEC (CC DISTRICT)City of Philadelphia · 2018
INSTALL OF 20-IP CAMERAS AND 1-NEW WALL MOUNTED,CORD AND PLUG CONNECTED MONITOR AND INSTALL NEW DIGITAL VIDEO RECORDER ONLY AS PER 2008 NEC (CC DISTRICT)City of Philadelphia · 2018
INSTALL FIRE ALARM SYSTEM ON LEVEL 1 RESTAURANT COMCAST BUILDING PERMIT #701516 AS PER PLANS PER 2008 NEC.City of Philadelphia · 2018
EXISTING SERVICE TO FEED 1-NEW 20A CIRCUIT FOR 3-NEW EXTERIOR WALL MOUNTED LED LIGHT FIXTURES **NO BLDG PERMIT ON FILE** AS PER NEC 2008 WEST DISTRICTCity of Philadelphia · 2018
AMEND PERMIT FOR RAY ANGELLINI TO REDUCE SCOPE OF WORK FROM PERMIT #626305 (ELECTRICAL PERMIT).THE SCOPE INCLUDES DELETING LIGHTING IN LOBBY AND AMENITIES ROOMS, E-101, E102, E-103,E-105,E-108, E-109,E-110, E111,E-101M, E108M,E-109M,E-110M,E-116, E-117,E-115M,304C,303,304B,300,304A,301 & 302.
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
COMPLETE RENOVATION AND UPGRADE OF ELECTRICAL SYSTEM THROUGHOUT SPACE IN SUB CONSOURSE LEVEL OF MUNICIPAL SERVICES BUILDING FOR NEW COMMUNITY CENTER.City of Philadelphia · 2017
REPLACE ONLY ONE FOR ONE EXISTING LIGHT FIXTURES (44) WITH NEW LED FIXTURES WITH NO ADDITIONAL LOAD IN OUTDOOR PLANTERS BEDS AS PER NEC 2008City of Philadelphia · 2017
INSTALL SECONDARY CONDUITS FROM PECO TRANSFORMER TO FUTURE TENANTS GEAR LOCATION. PROVIDE SWITCH FOR FIRE PUMP. INSTALL TEMP LIGHTING 120/208 - 150AMP TO BE FED FROM EXISTING PANEL. INSTALL FIRE ALARM FOR FIRE PUMP.City of Philadelphia · 2017
INSTALL FIRE ALARM SYSTEM ON FLOORS 1, 2, 5 IN THE NEW COMCAST BUILDING. AS PER NFPA 72 CC DISTRICTCity of Philadelphia · 2017
ELECTRICAL WORK TO INCLUDE ALL POWER, LIGHTING, MECHANICAL EQUIPMENT CONNECTIONS, TELE/DATA CABLING ONLY, AREA OF RESCUE, SECURITY AND TEMP POWER AS PER 2008 NEC (SOUTH DISTRICT) INSTALL COMPLETE FIRE ALARM SYSTEM WITH PULLSTATIONS,HORNS,STROBES AND LIGHTS AS PER NFPA 72City of Philadelphia · 2017