What the public permit record shows, not self-reported reviews.
Is RASHEED MOSS a real contractor?
RASHEED MOSS appears in public building-permit records with 64 permits filed through 2025 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is RASHEED MOSS's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to RASHEED MOSS by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is RASHEED MOSS licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. RASHEED MOSS has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is RASHEED MOSS's work?
The most recent permit on record for RASHEED MOSS is dated 2025-10-31, with 64 permits on file in total.
INSTALL 100 AMP ELECTRICAL SERVICE WITH MAIN CIRCUIT BREAKER PANEL AND PROPER GROUNDING AND BONDING. REWIRE HOUSE THROUGHOUT. INSTALL LIGHTING, SWITCHES AND RECEPTACLES OUTLETS. INSTALL 120 VOLTS INTERCONNECTED SMOKE/CO ALARMS ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC.City of Philadelphia · 2025
Amended 12/3/25
Install a new fire alarm In accordance with NFPA 72 2016 & The Philadelphia Fire Code 2018
Install a 300-amp service to supply a completely rewired triplex.
Install a four-gang meter socket with (4) 100 amp disconnects.
Install new switches, receptacles, LED light fixtures, emergency lights, and hardwired smoke detectors.
Grounded and bonded.City of Philadelphia · 2025
Install wiring for an exterior light fixture and receptacle.
Install an exterior light fixture and receptacle.City of Philadelphia · 2025
Rewire a single family dwelling
Install new wire, receptacles, switches, LED lighting fixtures, and hardwired smoke/CO2 detectors where required.
Install a new 200amp service
40 space panel, ground and bond the electrical system
All work will be installed per 2017 NECCity of Philadelphia · 2025
INSTALL A 400 AMP SERVICE, (5) GANG METER BANK, (4) 100 AMP PANELS & FEEDERS, (1) 60 AMP PANEL & FEEDER. ALL WORK IN ACCORDANCE WITH THE 2017 NEC.
* THE PERMIT IS FOR THE SERVICE, PANELS & FEEDERS ONLY.
* NO BRANCH CIRCUIT WIRING OR FIRE ALARM WORK ON THIS PERMIT.City of Philadelphia · 2025
Install a 400 amp service. Complete rewiring of an existing four-family structure. Install new switches, receptacles, light fixtures, and hardwired smoke detectors.
Install a new fire alarm control panel.
Install new horns, strobes, smoke detectors, and pulls. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.
**CHECK YOUR LOW FREQURENCY SOUNDER MODEL# ON RECALL SHEET**
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you RASHEED MOSS?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2024
Complete rewire
Install new receptacles, switches, LED light fixtures, and hardwired smoke and CO2 detectorsCity of Philadelphia · 2024
Install a 200 amp service
2 gang meter socket with 100 amp breakers for each position
Grounded and bonded
All work will be installed per 2017 NECCity of Philadelphia · 2024
Complete rewire
Install new switches, receptacles, LED light fixtures, and hardwired smoke and CO2 detectors where required
All work will be installed per the 2017 NECCity of Philadelphia · 2024
For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.City of Philadelphia · 2024
Install a 200 amp service
200 amp meter socket
40 space main breaker panel
Grounded and bondedCity of Philadelphia · 2024
Rewiring of an existing commercial building. The wiring will conform with the 2017 NEC.City of Philadelphia · 2024
Permitted projects on public record. Addresses are omitted for privacy.