What the public permit record shows, not self-reported reviews.
Is QRS, LLC a real contractor?
QRS, LLC appears in public building-permit records with 46 permits filed through 2025 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is QRS, LLC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to QRS, LLC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is QRS, LLC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. QRS, LLC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is QRS, LLC's work?
The most recent permit on record for QRS, LLC is dated 2025-08-06, with 46 permits on file in total.
FOR THE STRUCTURAL REPAIR TO EXTERIOR WALL TO RESOLVE CASE #CF-2025-023738. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CASE #CF-2025-023738.City of Philadelphia · 2025
FOR LEVEL I ALTERATIONS TO INCLUDE THE REPLACEMENT OF INTERIOR FRAMING, DRYWALL, AND INSULATION IN KIND AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.City of Philadelphia · 2024
RENOVATION TO INCLUDE A KITCHEN STRUCTURAL BEAMCity of Philadelphia · 2023
FOR INTERIOR ALTERATION AND FLOOR JOISTS REPLACEMENT ON FIRST FLOOR AS PART OF AN EXISTING STRUCTURE TO CONTINUOUS USE AS SINGLE-FAMILY DWELLING. THE EXISTING BASEMENT TO REMAIN NON-HABITABLE SPACE. SIZE AND LOCATION AS SHOWN ON THE PLANS.
** SEPARATE PERMIT REQUIRE FOR ELECTRICAL, PLUMBING AND MECHANICAL **City of Philadelphia · 2023
For reconstruction of the roof and other structural repairs to the existing detached garage structure per plans.
Amended 12/5/2022 for update roof framing details.City of Philadelphia · 2022
Installing start bolts on the front elevation of the house (details as per plan).City of Philadelphia · 2021
FOR THE RECONSTRUCTION OF AN AWNING COVERAGE LOCATED AT THE GROUND FLOOR TO INCLUDE FLASHING AND RAFTER/JOIST FRAMING INSTALLATION. (IRC 2015)City of Philadelphia · 2021
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you QRS, LLC?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
EZ PERMIT STANDARDS ALTERATIONS - For alterations to an Existing One Family Dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Structural alteration or repair is expressly prohibited under this permit. Prohibited structural work any modifications to exterior walls, party walls, floor/roof framing or foundations, including underpinning, excavation, and removal of foundation slab. WORK IN THE BASEMENT OR CELLAR IS NOT INCLUDED ON THE EZ ALT PERMIT. Separate permits required for Mechanical, Electric and Plumbing. Bathroom remodel. Moving back a non load bearing wall 2 foot into middle bedroom to make to the 2nd Floor Hall bathroom bigger.City of Philadelphia · 2021
LEVEL-1 ALTERATION: EZ PERMIT STANDARDS ALTERATIONS - Level-1 Alteration: To an existing two-family dwelling - No framing, layout changes, or work to any rated assemblies approved on this permit. Structural alteration or repair is expressly prohibited under this permit. Prohibited structural work includes any modifications to exterior walls, party walls, floor/roof framing or foundations, including underpinning, excavations (i.e. digging in Basement) and removal of basement slab. *Work in the basement or cellar is not allowed on the EZ Alteration Permit.*. Separate permits required for Mechanical, Electric and Plumbing. Interior non weight bearing walls for insulation and gypsum wall board.City of Philadelphia · 2021
Alteration: Interior building; existing single family dwelling; restoration of structure from fire as per approved plans.City of Philadelphia · 2021
MAKE SAFE PERMIT TO COMPLY WITH CASE# CF-2020-62275. ALTERATION TO INCLUDE REPAIR OF THE ROOF TRUSS SYSTEM(DAMAGED BY FIRE) OF AN EXISTING ATTACHED STRUCTURE. REPAIRS TO BE PERFORMED PER ENGINEER'S REPORT AND APPROVED PLANS. ABUTTING SIDEWALK MUST BE CLOSED WITH FENCING A MINIMUM OF 6’ IN HEIGHT. SEPARATE STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CASE #CF-2020-62275.**EXTERIOR WORK ONLY**City of Philadelphia · 2020
The rear stud wall and floor framing for the kitchen area should be replaced.
1. Install temporary shoring to maintain a safe working environment. Use (2) 2x12 diagonal
braces at 4 foot spacing, notched to support second floor framing above kitchen.
2. Remove and replace kitchen cabinets and countertops.
3. Remove and replace existing first floor rear stud wall from the second floor framing down to the foundation wall. This includes a door, a window, exterior and interior finishes, and insulation.
5. Form and pour a concrete threshold at the existing rear door.
6. Remove and replace kitchen floor (floor covering, sheathing, and framing). Install new center PT 2x6 knee wall on an 8 inch thick by 16 inch wide strip footing. Install new PT 2x8 ledgers to the left and right masonry walls with (2) 1/4 x 4 Tapcon screws at 16 inch spacing. Install new 2x8 floor joists at 16” spacing. Install new 3/4” tongue and groove plywood floor sheathing.City of Philadelphia · 2020