Installation of power to 1st floor mini split disconnect.
Installation of power to 2nd floor mini split disconnect
Installation of 2- 30 Amp double pole breakersCity of Philadelphia · 2026
Wire 3 units: lights, receptacles and switches
Install feeds four individually metered breakers (one 100A and three 125A).
• Those breakers feed four 125-amp tenant panels, ( 1 panel per unit, and 1 house panel.
Install a complete fire alarm system including (1) control panel, (1) annunciator, (1) power booster, (3) pull stations, (1) duct detector, (2) flow switches, (2) tamper switches, (2) monitor modules, (1) relay module, (6) low frequency horn/strobes. PER APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.
-NOTED: Install 400-amp service from front of BLDG to side under slab 18" to meter bank on side of BLDG(SEE ENGINEER/CITY APPROVED DRAWINGS)City of Philadelphia · 2026
Full rewire: lights, switches, and receptacles
Adding hardwired smoke detectors
200 amp service: grounding and bondingCity of Philadelphia · 2026
Full rewire: Lights, switches and receptacles.
Adding hardwire smoke detectors
200 amp Service: grounding and bondingCity of Philadelphia · 2026
Full rewire: Lights, switches and receptacles.
Hardwire smoke detectors.
Upgrading 200 amp service: Grounding and bondingCity of Philadelphia · 2026
Full rewire: lights, switches and receptacles. Adding hardwired smoke detectors. 200 amp service: grounding and bonding.City of Philadelphia · 2026
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
INSTALL 200 AMP ELECTRICAL SERVICE, METER SOCKET AND CIRCUIT BREAKER PANEL WITH PROPER GROUNDING AND BONDING. REWIRE HOUSE THROUGHOUT AND INSTALL LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. INSTALL 120 VOLTS INTERCONNECTED SMOKE AND CO ALARMS ACCORDING TO THE 2017 NEC.City of Philadelphia · 2026
100 amp service panel and meter : grounding and bondingCity of Philadelphia · 2026
Full rewire: lights,switches and receptacles. Adding hardwired smoke detectors. 200 amp service feeding 2- 100 amp subpanel one for each unit and a 100 amp house subpanel.City of Philadelphia · 2026
Full rewire: lights, switches and receptacles. Adding hardwired smoke detectorsCity of Philadelphia · 2025
Full rewire for 2 units: Lights, switches and receptacles. Adding hardwired smoke detectors. 200 amp service feeding each unit with 100 amp subpanel and 100 amp house subpanel. grounding and bondingCity of Philadelphia · 2025
Full rewire of 2 units: lights, switches, receptacles. Adding hardwire smoke detectors. 200 amp service feeding each unit with 100 amp subpanel and 1- 100 amp subpanel for the house panel. grounding and bondingCity of Philadelphia · 2025