What the public permit record shows, not self-reported reviews.
Is MJ KELLY ELECTRIC INC a real contractor?
MJ KELLY ELECTRIC INC appears in public building-permit records with 87 permits filed through 2023 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is MJ KELLY ELECTRIC INC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to MJ KELLY ELECTRIC INC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is MJ KELLY ELECTRIC INC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. MJ KELLY ELECTRIC INC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is MJ KELLY ELECTRIC INC's work?
The most recent permit on record for MJ KELLY ELECTRIC INC is dated 2023-05-24, with 87 permits on file in total.
Electrical Permit for combo CP-2023-001064City of Philadelphia · 2023
(238) Fixtures
(1) FA Panel
(1) Duct Detector
(25) Smoke Detectors
(36) Speaker/Strobes
(3) Strobes
(1) Single
(115) Duplex
(12) Duplex GFI
(99) Quad
(2) Quad GFI. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.City of Philadelphia · 2022
Scope of work includes:
- 3,517 Fixtures
- 2,834 Duplex Receptacles
- 203 Smoke Detectors
- 28 Duct Detectors
- 331 Horn Strobes
- 31 Pull Stations
- 333 Strobes
As per 2017 NEC and 2016 NFPA 72City of Philadelphia · 2022
This job space includes:
- 968 Lighting Fixtures
- 585 Receptacles
-1600 Amp 3 Phase Service
Temp 200 Amp Service
As per 2017 NEC.
- Code compliant fire alarm system
As per 2016 NFPA 72City of Philadelphia · 2022
100 Amp sub-panel; circuit for hot water heater, hvac unit connections,
new kitchen branch circuits and appliance circuits, new high hat lighting throughout as per 2014 NECCity of Philadelphia · 2022
This job site includes:
-29 Light Fixtures
-10 USB Duplex
-1 GFI Duplex
-5 Data Outlets
As per 2017 NEC.City of Philadelphia · 2021
Installation of Temporary 200 AMP Single Phase Service as per 2017 NECCity of Philadelphia · 2021
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you MJ KELLY ELECTRIC INC?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to MJ KELLY ELECTRIC INC's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
Renovation of the 10th Floor. Installation of (521) LED lights, (228) Lighting control devices, (420) receptacles, (850') wiremold, (44) exits, (34) 150 amp lab panels, (1) 4000 amp substation, (1) 2500 KVA Transformer, 13.2 KV Switch as per 2017 NEC. Install (22) ceiling speaker strobes, (50) wall speaker strobes, (20) smoke detectors, (8) duct detectors, (4) door hold openers as per 2016 NFPA 72.City of Philadelphia · 2021
Installation of (1) 30KVA transformer, (1) panel ELSP5-1, (1) EQRPL, (1) Panel DEQRPL, (45) LED light fixtures, branch power for (2) dental operatory areas, (1) procedure room and support space AS PER THE 2017 NEC.City of Philadelphia · 2021
The building consists of:
- 46 Total Apartments
- 545 Total Lights
- 125 KW Generator
- 600 Amp Manual Transfer Switch
- 230 Amp Automatic Transfer Switch
- 1200 Amp Tenant Metering Panel
- 1600 Amp Switchboard Panel
- Misc. house panels
- 525 Duplex Receptacles
- 406 GFI Duplex Receptacles
as per 2017 NEC.
- 138 Fire Alarm Mini Horn
- 41 Fire Alarm Horn
- 174 Fire Alarm Flashing Lights
- 18 Fire Alarm Manual Pull Station
- 86 Automatic Detector - CO
- 9 Automatic Detector - F
- 2 Automatic Detector - PE
as per 2016 NFPA 72City of Philadelphia · 2021
(1) 800 amp house distribution panel, (7) branch electrical panels, (1) 800 amp apartment meter bank, (50) HP fire pump, (1) 80 KW diesel gen, (643) LED Light fixture, (1194) receptacles as per APPROVED -2017 nec.
**SEPARATE FIRE ALARM PERMIT REQUIRED FOR ANY FIRE ALARM**City of Philadelphia · 2021
Utilize existing panels to install (46) receptacles, (28) LED light fixtures, and (3) exit signs in reconfigured retail pharmacy space as per 2017 necCity of Philadelphia · 2020
Permitted projects on public record. Addresses are omitted for privacy.