Electrical work only: Install new conduit and wiring for branch circuits, devices, lighting, and associated wiring for elevator modernization.
Replace existing circuit breaker and install new breaker, conduit, and wiring for new elevator feeder as per 2017 NEC.
Upgrade existing fire alarm with new devices for elevator recall as per 2016 NFPA 72.City of Philadelphia · 2026
Electrical work only: Install new branch circuits, devices, lighting, and associated wiring for elevator modernization as per 2017 NEC. Alterations to existing fire alarm system as per 2016 NFPA 72.City of Philadelphia · 2026
Install new low voltage transformers, panelboards, and ATS's from existing distribution panels and transformers for new feeder conduit and wiring to accommodate elevator modernization as per 2017 NEC.City of Philadelphia · 2026
Install new elevator main line and cab light disconnects fed from existing feeder. Install new lighting and power devices in elevator machine room and pits as per 2017 NEC.
Install new fire alarm devices as per 2016 NFPA 72.City of Philadelphia · 2025
Demo existing elevator equipment feeders, wiring, and gear.
Install new conduit and wiring from basement mechanical room to elevator machine room. Install new circuit breaker in SDS, intercept generator feeder to install new switchboard and ATS for new elevator equipment per E-101 single-line. Alter existing fire alarm to accommodate new equipment. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.
AMENDMENT: Install fire alarm per sealed approved drawings.City of Philadelphia · 2025
Install new conduit and wiring from basement mechanical room to elevator machine room. Demo existing gear and install new according to E-100 single line diagram. Alter existing FA to accommodate new elevator equipment. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2018 PHILA FIRE CODE.
AMENDMENT: Install fire alarm PER APPROVED DRAWINGS for elevator modernization .
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
REMOVE THE EXISTING EMERGENCY FEEDERS & DISCONNECTS TO THE ATS, EMERGENCY PANELS & ELEVATOR EQUIPMENT. INSTALL A NEW 600 AMP CIRCUIT BREAKER IN THE EXISTING EDP PANEL. INSTALL EMERGENCY FEEDER TO THE 150KVA TRANSFORMER, DISCONNECTS, ATS, EMERGENCY PANELS & ELEVATOR EQUIPMENT. INSTALL A NEW START CIRCUIT FROM THE ATS TO THE GENERATOR. ALL WORK IN ACCORDANCE WITH THE APPROVED DRAWINGS-2017 NEC.
NOTED: Elevator disconnect removed from emergency power ATS and moved to stand-by loads (see drawings).City of Philadelphia · 2025
Install new FA emergency responder communication enhancement system throughout building (ERCES). All work is to be done according to approved drawings-2017 NEC 2016 NFPA-1221 , 2016 NFPA-72 ,2018 PHILA FIRE CODE.City of Philadelphia · 2025
AMENDMENT: Install fire alarm system as per 2016 NFPA 72 and sealed fire alarm drawings.
-Install new transformer and panelboard for new lighting and power branch circuits as per 2017 NEC.
***Fire Alarm will be submitted at a later date***City of Philadelphia · 2024
Rough-In Permit for EP-2024-010490 -Install new transformer and panelboard for new lighting and power branch circuits.
-Install new fire alarm devices and tie into existing system **Fire alarm drawings to be submitted upon receipt**City of Philadelphia · 2024
Upgrade existing fire alarm with new addressable system for elevator modernization project as per 2016 NFPA 72. Replace existing FACP with addressable unit. Replace conventional initiating devices with addressable devices. Replace bells with horn/strobes. Program elevator smoke detectors for elevator recall function. Install and program relay modules for elevator recall function.City of Philadelphia · 2024
INSTALL NEW FIRE ALARM HEAT DETECTORS & CONTROL MODULES IN THE ELEVATOR LOBBIES & ELEVATOR CONTROLLERS. ALL WORK INACCORDANCE WITH THE 2017 NEC.City of Philadelphia · 2024