What the public permit record shows, not self-reported reviews.
Is LIU CONSTRUCTION LLC a real contractor?
LIU CONSTRUCTION LLC appears in public building-permit records with 46 permits filed through 2023 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is LIU CONSTRUCTION LLC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to LIU CONSTRUCTION LLC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is LIU CONSTRUCTION LLC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. LIU CONSTRUCTION LLC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is LIU CONSTRUCTION LLC's work?
The most recent permit on record for LIU CONSTRUCTION LLC is dated 2023-11-01, with 46 permits on file in total.
FOR LEVEL II EXTERIOR ALTERATIONS TO AN EXISTING ATTACHED STRUCTURE. ALTERATIONS TO INCLUDE THE INSTALLATION OF A NEW EXTERIOR WALL OPENING. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.City of Philadelphia · 2023
FOR SITE WORK FOR ON-SITE UTILITIES TO INCLUDE THE INSTALLATION OF A TWO (2) INCH FIRE SERVICE MAIN AS PER APPROVED PLANS.City of Philadelphia · 2023
FOR INETRIOR LEVEL 2 ALTERATIONS TO THE BASEMENT AND GROUND FLOOR OF AN EXISTING STRUCTURE AS PER PLANS. FOR FIT-OUT OF A SIT-DOWN RESTAURANT.
AMENDMENT (11/13/2023) FOR INTERIOR LAYOUT CHANGES AS PER REVISED PLANS.City of Philadelphia · 2023
FOR EXCAVATION SHEETING AND SHORING TO INCLUDE UNDERPINNING, AND SOLDIER PILES, AS PER APPROVED PLANS.City of Philadelphia · 2023
FOR THE ERECTION OF A THREE (3) STORY STRUCTURE OF TYPE V-B CONSTRUCTION FOR USE AS ONE (1) VACANT COMMERCIAL SPACE (SEPARATE PERMITS REQUIRED FOR FIT-OUT & ISSUANCE OF C.O.) AND FIVE (5) DWELLING UNITS (GROUP R-2). BUILDING TO BE FULLY SPRINKLERED THROUGHOUT PER NFPA 13. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IBC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK.City of Philadelphia · 2023
FOR NEW CONSTRUCTION OF A SEVEN (7) STORY STRUCTURE (CONSTRUCTION TYPE IA & IIIA), CONTAINING TWENTY-FOUR (24) DWELLING UNITS & VACANT COMMERCIAL SPACE (SEPARATE PERMIT REQUIRED PRIOR TO OCCUPANCY) WITH ROOF DECKS, ROOF DECK ACCESS STRUCTURES, AND ACCESSORY CAR & BICYCLE PARKING AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED PER NFPA 13. SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK. *2018 IBC REVIEW*
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you LIU CONSTRUCTION LLC?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to LIU CONSTRUCTION LLC's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2022
LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY ON THIS PERMIT) FOR STRUCTURAL WORK TO INCLUDE UNDERPINNING AND ERECTION OF A NEW INTERIOR MEZZANINE IN AN EXISTING MIXED USE BUILDING AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR FIT-OUT WORK. *UNDERPINNING TO BE MONITORED BY A PA LICENSED PE AT ALL TIMES* *2018 IEBC REVIEW*
**SEPARATE PERMITS REQUIRED FOR ANY MEP WORK**
AMENDMENT APPROVED 2/18/23
AMEND ALTERATIONS PERMIT CP-2022-002767 FOR CHANGE TO SPECIAL INSPECTIONS AGENCY AS PER APPROVED REVISED SPECIAL INSPECTIONS DOCUMENT.
AMENDMENT APPROVED 4/30/23
AMEND ALTERATIONS PERMIT CP-2022-002767 FOR CHANGE TO SPECIAL INSPECTIONS AGENCY AND DPRC-SI AS PER APPROVED REVISED SPECIAL INSPECTIONS DOCUMENT.City of Philadelphia · 2022
FOR THE ERECTION OF AN ATTACHED THREE STORY STRUCTURE WITH ROOF DECK ACCESSED BY A ROOF DECK ACCESS STRUCTURE (ACCESSED BY UNIT 3 ONLY). STRUCTURE FOR USE AS MULTI-FAMILY HOUSEHOLD LIVING (3 UNITS) WITH ONE INTERIOR ACCESSORY PARKING SPACE. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. **A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 9 FEET OF THE BUILDING FACADE IN ACCORDANCE WITH SECTION 3306 OF THE 2018 IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMIT REQUIRED PRIOR TO THE START OF ANY WORK.*** SEPARATE PERMIITS TO BE OBTAINED FOR ALL OTHER WORK.City of Philadelphia · 2022
FOR THE CONSTRUCTION OF AN ATTACHED STRUCTURE WITH CELLAR AND ROOF DECK ACCESSED BY A ROOF DECK ACCESS STRUCTURE. FOR A SINGLE-FAMILY HOUSEHOLD LIVING. AS PER PLANS. ************ NO UNDERPINNING ON THIS APPLICATION. SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, MECH., OR ELECTRICAL WORK. *******************************City of Philadelphia · 2021
FOR THE CONSTRUCTION OF A THREE-STORY STRUCTURE WITH CELLAR AND PILOTHOUSE TO ACCESS ROOF DECK, FOR USE AS A TWO-FAMILY DWELLING, AS PER APPROVED PLANS.City of Philadelphia · 2021
NEW CONSTRUCTION OF A THREE(3) STORY BUILDING(BUILDING 1) FOR A MULTI-FAMILY HOUSEHOLD LIVING FOR THREE DWELLING UNITS. WORK TO BE PERFORMED AS PER APPROVED PLANS.** BUILDING TO BE FULLY SPRINKLERED PER NFPA 13R MIN**SEPARATE PERMITS REQUIRED FOR MECHANICAL,ELECTRICAL,PLUMBING & FIRE SUPPRESSION WORK**SPECIAL INSPECTIONS TO BE MONITORED AT ALL TIME BY THE APPROVED SPECIAL INSPECTION AGENCY/INDIVIDUAL**City of Philadelphia · 2021
FOR THE ERECTION OF A FOUR (4) STORY STRUCTURE FOR USE AS TWO-FAMILY HOUSEHOLD LIVING. SHEETING AND SHORING AS PRESCRIBED IN GEOTECH REPORT. SEPARATE PERMITS REQUIRED FOR SPRINKLER (13R) WORK. ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C/O SUBMITTAL OF AIR BARRIER CHECKLIST AND ENVELOPE TESTING CERTIFICATE IS REQUIRED. BOTH TO BE COMPLETED BY AN APPROVED PARTY.City of Philadelphia · 2021
Permitted projects on public record. Addresses are omitted for privacy.