LEUZZI BROTHERS INC appears in public building-permit records with 50 permits filed through 2026 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is LEUZZI BROTHERS INC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to LEUZZI BROTHERS INC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is LEUZZI BROTHERS INC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. LEUZZI BROTHERS INC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is LEUZZI BROTHERS INC's work?
The most recent permit on record for LEUZZI BROTHERS INC is dated 2026-01-21, with 50 permits on file in total.
**LEVEL 3 ALTERATIONS & ADDITION ** FOR THE ERECTION OF AN ADDITION AT THE REAR OF AN EXISTING COMMERCIAL STRUCTURE FOR USE AS ARTIST STUDIOS (B OCCUPANCY) AND ONE (1) DWELLING UNIT (R-3 OCCUPANCY). ALTERATIONS TO INCLUDE THE ERECTION OF AN ADDITION, PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. **MECHANICAL PERMITS REQUIRED FOR FACTORY-BUILT WOOD BURNING FIREPLACE** ELEVATOR PERMIT FROM THE COMMONWEALTH OF PENNSYLVANIA IS REQUIRED ** EXCAVATION PERMIT REQUIRED ** ASBESTOS REMEDIATION REQUIRED **
**PERMIT AMENDMENT REQUIRED FOR FINAL POOL DESIGN**NO MORE THAN 2/3 OF ALL STRUCTURAL FRAMING MEMBERS MAY BE REMOVED/REPLACED UNDER THIS PERMIT**City of Philadelphia · 2026
EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans.
Install two new HVAC systems, one for the basement and first floor, the other for the second floor and the third floor. New ductwork and 20 registers throughout.City of Philadelphia · 2025
For the erection of an addition, to include a roof deck and pilot house, and interior and exterior alterations to an existing attached single-family dwelling per plans. Separate permits are required for all associated Mechanical, Electrical, and Plumbing work. Basement to remain non-habitable, to be used for storage and utilities only.City of Philadelphia · 2025
FOR THE ERECTION OF A 2ND AND THIRD FLOOR ADDITION WITH ROOF DECK ACCESSED BY THE THIRD FLOOR INCLUDING INTERIOR ALTERATIONS THROUGHOUT AN EXISTING ATTACHED STRUCTURE FOR USE AS A SINGLE-FAMILY DWELLING; SIZE AND LOCATION AS PER APPLICATION/PLAN.City of Philadelphia · 2025
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you LEUZZI BROTHERS INC?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to LEUZZI BROTHERS INC's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
FOR LEVEL II INTERIOR ALTERATIONS WITH A PARTIAL CHANGE IN OCCUPANCY TO GROUP B BUSINESS & PROFESSIONAL OFFICE AT THE 1ST FLOOR. EXISTING BUILDING IS NOT SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK.City of Philadelphia · 2024
EZ PERMIT STANDARDS ALTERATIONS- For alterations to an Existing One Family Dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Separate permits are required for plumbing and electrical work and the installation of heating/cooling appliances. STRUCTURAL ALTERATION OR REPAIR IS EXPRESSLY PROHIBITED UNDER THIS PERMIT. PROHIBITED STRUCTURAL WORK INCLUDES ANY MODIFICATION TO EXTERIOR WALLS, PARTY WALLS, FLOOR/ROOF FRAMING OR FOUNDATIONS; INCLUDING UNDERPINNING, EXCAVATION, AND REMOVAL OF FOUNDATION SLAB.NO WORK MAY BE PERFORMED IN THE BASEMENT OR CELLAR.City of Philadelphia · 2024
MAKE SAFE PERMIT - For FACADE REPAIRS AS PER PLANS AND ENGINEER REPORT to resolve case CF#2024-005297. Abutting sidewalk must be closed with fencing a minimum of 6’ in height. Separate Streets Department permit required for sidewalk closure. A Separate permit is required for any additional alterations that are not specifically addressed on case #2024-005297. In accordance with Code Bulletin PM-1801, a PA professional engineer is required to monitor repairs made under this permit. The engineer must submit a sealed statement to the Department confirming that the structure is in sound condition at completion.City of Philadelphia · 2024
INTERIOR ALTERATION TO AN EXISTING THREE (3) STORY SINGLE-FAMILY DWELLING AS PER APPROVED PLANS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT THE DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.
** SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK **City of Philadelphia · 2024
EZ PERMIT STANDARDS ALTERATIONS
For alterations to an existing one family dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Structural alteration or repair is expressly prohibited under this permit. Prohibited structural work includes any modification to exterior walls, party walls, floor/roof framing or foundations, underpinning and excavations (i.e., digging in basement). Any work/alterations to the basement/cellar are expressly prohibited unless documented as an existing habitable space with heights and means of egress per conditions of the EZ standard. separate permits required for mechanical, electric and plumbing, etc.
*No basement alterations of any kind were proposed or approved for this permit*
*No structural alterations of any kind were proposed or approved for this permit*
THE APPROVED ALTERATIONS FOR THIS PERMIT INCLUDE THE FIRST AND SECOND FLOOR ONLY. NO BASEMENT.City of Philadelphia · 2023
For the addition of the exterior deck and stairs. Interior renovations on the first floor per plans. Separate permits are required for all associated Mechanical, Electrical, and Plumbing work.City of Philadelphia · 2023
For interior non-structural alterations to Unit 1 of an existing Two Family Dwelling per plans. Separate permits are required for all associated Mechanical, Electrical, and Plumbing work. Basement to be used for storage and utilities only.City of Philadelphia · 2023
For Level II Alterations (w/o a change of occupancy) to an existing Group B occupancy (Deli w/<50 occupants w/accessory storage w/in the basement) at the basement and first floor of an existing three (3) story attached structure, as per plans; no structural work on this permit; separate permits required for all MEP work; building is currently not sprinklered; no signs on this permit.City of Philadelphia · 2022