What the public permit record shows, not self-reported reviews.
Is L MOORE ELECTRIC INC a real contractor?
L MOORE ELECTRIC INC appears in public building-permit records with 175 permits filed through 2026 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is L MOORE ELECTRIC INC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to L MOORE ELECTRIC INC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is L MOORE ELECTRIC INC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. L MOORE ELECTRIC INC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is L MOORE ELECTRIC INC's work?
The most recent permit on record for L MOORE ELECTRIC INC is dated 2026-05-22, with 175 permits on file in total.
Install 200 amp Single phase Service and tie in existing loads. Ground Service as per CodeCity of Philadelphia · 2026
INSTALL 1000 AMP ELECTRICAL SERVICE AND 9 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE SUBPANELS FOR HOUSE AND 8 SUBPANELS FOR DWELLING UNITS. INSTALL WIRING, LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. INSTALL INTERCONNECTED SMOKE AND CO ALARMS ACCORDING TO THE 2017 NEC. INSTALL FIRE ALARM SYSTEM ACCORDING TO THE 2016 NFPA 72 AND PER PLANS.City of Philadelphia · 2025
Install 3 phase 120-208 v service
Install 1 meter bank system with a 1200 amp disconnect and (28) 150amp , (4) 200 amp feeders and meters for apartments.
Install 2 400 amp 3 phase service for 2 commercial spaces.
Install 300 amp 3 phase service for House Panel
Ground Services as per Code
Install complete Fire Alarm System with a 2 way (RAS/AOR)communication system
Install wiring for 1 Elevator
Install and Wire complete wiring system for all devices, 110v SMOKE/CARBON ALARMS, Lighting, Exhaust Fan, TV and Telephone
Install wiring for the mechanical and hvac equipment .ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.
Install Temporary 200 amp service and temporary power throughout building for the duration of the project .
-NOTED: CLOUDED FOR MISSING DIRECTIONAL EXIT/EM.LIGHTING-
** SEPARATE FITOUT E.PERMITS REQ"D FOR WIRING AND FIRE ALARM FOR COMMERCIAL SPACES **City of Philadelphia · 2025
Install Pipe and Wire New 100 amp SEU Wire and 100 Amp Meter Socket
Remove existing wire that is damaged by weather
Install pipe and wire from meter to panel
Tie in new wire to existing 100 Amp Panel
Ground Service as Per Code
Install Ground Rods and Ground water meter
Fish Ground Wire to water meter closet
Remove squares of drywall where needed to fish wire keeping to a minimum and re-install drywall square once finishedCity of Philadelphia · 2024
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you L MOORE ELECTRIC INC?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to L MOORE ELECTRIC INC's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
4th Fl. Re-wire & 2nd Fl. Bedroom and Bathroom
4th Floor
Install and Wire 3 Bedrooms
1 Fan
1 Switches
Outlets to Code and drawing
1 Smoke (120v)
1 TV/CAT5 to each bedroom
Bathroom
Install and Wire Bathroom
1 Emergency Light
2 LED RAB Surface mount lights
1 Vanity
1 Exhaust Fan
3 Switches
1 GFI
Hallway
Install and Wire 4 RAB LED Surface Lights
Outlets to Code and Drawing
1 3-way/4-way system
1 Switch
1 Light & Switch Closet
1 GFI Closet
Relocate Sub-Panel in middle Bedroom to Hallway
Demo existing Sub Panel wire from 4th Fl to Basement Panel
Install fish and Wire new 100 amp SER Wire from existing 200 amp panel in basement to relocate Sub Panel in 4th Fl to bring up to Code
Heater Wiring on 4th fl. to remain existing
A/C Unit on roof to remain existing
Demo and relocate existing wires as per Code
Basement
Install new 100 SER Wire from existing main 200 Amp Panel to existing 100 amp panel in basement
Separate all Grounds and Neutrals to meet Code
All Panels in Basement remain existing
Ground Panel as per Code
Wire fire Alarm Devices as per Drawing and tie into existing Fire Alarm System
2nd FLOOR
Demo and relocate all wires from existing 2 bedrooms being removed
Install fish and Wire 4 RAB LED Lights
1 Fan
2 Switches
2 RAB LED Light Bar
1 Switch
Outlets to Code and Drawing
1 Circuit for Bar Area
1 Fridge Circuit
1 Smoke/Carbon
Install fish and Wire 1 TV
1 Tele
1 Exit/Emergency Light
Bathroom 2nd Floor
Install fish and Wire 3 LED RAB Surface Lights
1 Vanity Light
1 Exhaust Fan
3 Switches
1 GFI
1 Emergency Light
All work is to be done according to approved drawings-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.City of Philadelphia · 2024
Install 2 x 200 amp feeders and 6 x 150 amp feeders m/c aluminum to each of the 8 apartments and from apartments to the basement
Install 8 Panels and all breakers
Install wiring for 1 Elevator
Install and Wire complete wiring system for all devices, 110v smokes, Carbon Smokes, Lighting, Exhaust Fan, TV and Telephone
Install wiring for the mechanical and HVAC equipment
Install Temporary 100 amp service and temporary power throughout building for the duration of the project
Service not Included in this Permit
Installation shall comply with 2017 NEC.
Install fire alarm as per 2016 NFPA 72City of Philadelphia · 2024
For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.City of Philadelphia · 2024
Basement
Laundry
Install and Wire 2 4” Recessed Lights
1 4” Recessed Light
2 Switches
1 Dryer
1 Washing Machine Outlet
2 Outlets
1 Smoke
Demo and Relocate existing wiring
Main Area, Basement
Install Fish and Wire 6 4” Recessed lights
7 Outlets
1 4” Recessed below stairs
1 Sconce Stairs
1 3-way system
1 Switch
1 Carbon Smoke
Demo and relocate existing wiring
Kitchen/Dining Area Off Kitchen
Install fish and Wire: 6 4” Recessed - Kitchen
2 4” Recessed – Dining off Kitchen
2 Pendants
3 Switches
1 3-way System
2 Outlets Island
Outlets to Code
2 GFI
1 Fridge
1 Micro
1 Disposal/ Dishwasher
1 Fridge
1 Hood
2 Counter Outlets Dining area
Under Cabinet lighting system and switch
3 Outlets Dining Room
Demo and Relocate switch and outlets as per Code
Powder Room
Install new fixture, ceiling
Install fish and wire GFI
Hall Bathroom
Install fish and wire :
1 Vanity light
1 4” Shower light
2 4” General recessed lights
1 Exhaust Fan
2 Switches
1 switch for Shower and exhaust Fan
1 GFI
Demo and Relocate wires in bathroom
Master Bath
Install fish and Wire 1 Vanity Light
1 4” recessed Shower Light
1 4” General recessed light
1 Exhaust Fan
2 Switches
1 Switch for Shower and exhaust fan
1 GFI
Demo and Relocate wires in bathroom
New Service
Install and Wire 200 amp service
Install 200 amp Panel 40 Circuit
Install Grounding as Per Code
Install 2 Ground Rods
ALL WIRING TO BE FISHED OR SURFACE MOUNT
AS PER NEC 2017City of Philadelphia · 2023
3 x Bedrooms:
Install fish and Wire: 1 Fan/Light, 1 Switch,1 Smoke
Outlets to Code
Hallway
Install fish and Wire 1 Light,1 Smoke/Carbon,2 Outlets,2 3-way system
Bathroom
Install fish and Wire 1 Light,1 Switch,1 GFI
Living Room
Install fish and Wire 1 Fan/Light,1 Switch,1 Outside Light,1 Switch
1 GFI Outside, Outlets as Per Code,1 Smoke
Dining Room
Install fish and wire 1 Light,1 Switch, Outlets to Code
Kitchen
Install fish and Wire 4 Recessed lights,1 Switch,2 GFI circuits, Outlets to Code,1 Micro,1 Fridge,1 Dishwasher & Disposal,2 Pendants
1 Switch/Dimmer ,Peninsula Outlets, Range
Pantry
Install fish and Wire 1 Light,1 Switch, Outlets to Code,1 Outside Light, 1 Outside GFI
Powder Room
Install fish and wire 1 Vanity Light,1 Switch,1 GFI
Basement
Install and Wire 2 Switches,6 LED Puck Lights,1 Smoke,
1 smoke/carbon,1 Laundry outlet pipe,1 Dryer Outlet Pipe,1 Heater Feed,1 Water Heater Outlet
Service
100 amp Existing Meter and Service Wire to PECO connection to remain existing
Install new 100 amp Service wire from meter to new 30 circuit panel in basement
Install new 30 circuit Panel with 100 amp main
Ground Service as per Code
As per 2017 necCity of Philadelphia · 2023
Re-Wire of Kitchen
Remove track lighting
Relocate switch and thermostat for heat in front foyer and fish
Demo exhaust fan over oven
Relocate Electric oven to new location
Install conduit if needed on brick wall
Install fish and wire:
3 light fixtures
1 light fixture over sink
LED Strip Lights under cabinets
2 Switches
1 Dimmer over sink light
Outlets to Code
1 Dishwasher
1 Disposal
1 Fridge
1 60 amp Range
1 Hood
2 20amp circuit outlets
1 Toe Kick Heater 20 amp
Dining Room:
Demo all track in living room
Install fish and wire:
1 3way system
3 sconces
4 pendants
2 dimmers
Remove 2gang box front door and install 4gang box for 2 new switches
Replace light in bathroom
Replace 2 Sconces in fireplace
Check for power in Baseboard Heat
Wire and Fish 2 outlets in Living Room
Baseboard Heat
Check all Baseboard Heaters make sure they are working
Bedroom:
Replace Ceiling Fan
Install fish and wire: 2 sconces in Alcove
1 3way system for sconce in entrance to bedroom
1 Switch in Hallway and 1 at side of the bed
Install and wire 2 closet lights and switches
Bathroom:
Relocate wiring for washer and dryer
Demo all wiring for old bathroom
Install and Wire:
2 Wall sconce
1 Light shower 4” Juno
2 Exhaust fan Panasonic
2 4” Juno lights
1 switch fan
1 sconce 1 dimmer
1 shower recessed
1 switch recessed
Relocate Thermostat for Baseboard Heat and test
Smoke Detector system:
Install fish and wire 2 carbon smoke and 1 smoke
Panel
Remove existing 200 amp Sub- panel and Install new 200amp 40 circuit Sub-panel in closet as per 2017 codeCity of Philadelphia · 2023
Remodel of existing 2 Bathrooms:
Bathroom 1
Install Fish and Wire: 2GFI outlets in recessed vanity mirror
2 vanity lights in recessed vanity mirror
3 3” wafer LED lights in shower
1 Exhaust Fan
3 4” recessed light for general area
1 Dimmer
3 Switches
Relocate existing GFI to new location
Bathroom 2:
Install fish and wire: 1 mirror outlet
1 mirror light
1 Exhaust Fan
2 3” Shower Lights
2 4” Recessed Lights
1 Dimmer
Relocate GFI to new location
As per 2017 necCity of Philadelphia · 2023
Basement
Install fish and wire 6 surface mount lights in large area in basement
Remove existing 3 lights and relocate wiring to suit new layout
Install fish, pipe and wire outlet as per Drawing
Install 30 amp circuit and disconnect for water heater
Install 60 amp circuit for Heater
Install light switch and GFI in HVAC Closet
Install Dimmer as per Drawing
1st Floor
Install fish and wire lighting to new drawing
Install switches as per drawing
Relocate outlets and emergency pack as per drawing
Install Dimmer as per drawing
Install fish and wire washing machine circuit
30 amp dryer
Lights in closet where needed
Kitchen
Install fish and Wire: 2 GFI Circuits
1 Micro
1 Dishwasher
1 Disposal and Switch
1 Range
Outlets per Code
Demo and relocate outlet and emergency pack where needed
Fire Alarm stays existing - Relocate Fire Alarm devices where needed
200 amp 3-Phase Panel – Existing – All circuits will be tied to this Panel
Price includes to cut drywall and make holes where needed to fish wires -
Price includes for Surface mount 6” Lights
ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.City of Philadelphia · 2023