What the public permit record shows, not self-reported reviews.
Is iTech Electric LLC a real contractor?
iTech Electric LLC appears in public building-permit records with 82 permits filed through 2026 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is iTech Electric LLC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to iTech Electric LLC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is iTech Electric LLC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. iTech Electric LLC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is iTech Electric LLC's work?
The most recent permit on record for iTech Electric LLC is dated 2026-04-24, with 82 permits on file in total.
For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.City of Philadelphia · 2026
Full electrical fit-out for a bakery, including new 400 A, 3-phase service, panels, lighting, and outlets as per approved plans and as per NEC2017
***NO FIRE ALARM ON THIS PERMIT***City of Philadelphia · 2026
Install switch, switch control wire customer provided light fixture or iTech provided recessed light
4th fl bathroom: (1) exhaust fan, (1) recessed light, (1) vanity light
2nd fl bathroom: (1) exhaust fan, (1) ceiling fixture
Relocate (1) GFCI receptacle in 4th floor bathroom (assumes dedicated bathroom circuit)
Relocate electrical wires that are in the way in 4th fl bathroom by installing (1) receptacle in hallway and (1) receptacle/j-box
in closet/bedroom
Install (2) customer provided light fixtures (existing wiring) in front exteriorCity of Philadelphia · 2026
INSTALL 200 AMP ELECTRICAL SERVICE AND MAIN CIRCUIT BREAKER PANEL WITH PROPER GROUNDING AND BONDING. INSTALL WIRING, RECEPACLE OUTLETS, LIGHTING AND SWITCHES, WHERE REQUIRED THROUGHOUT HOUSE. INSTALL SMOKE/CO ALARMS WITH 10 YRS BATTERY BACKUP. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND THE SCOPE OF WORK IN THE EXECUTED CONTRACT. (Fishing wires only)
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you iTech Electric LLC?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to iTech Electric LLC's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2026
INSTALL 400 AMP ELECTRICAL SERVICE AND 6 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE 60 AMP SUBPANEL FOR HOUSE AND ONE 125 AMP SUBPANEL FOR EACH OF THE 5 DWELLING UNITS. INSTALL WIRING, LIGHTING, SWITCHES, EXIT SIGNS, EMERGENCY LIGHTING AND RECEPTACLE OUTLETS. INSTALL INTERCONNECTED SMOKE AND CO ALARMS. INSTALL FIRE ALARM SYSTEM. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA 72 AND PER APPROVED PLANSCity of Philadelphia · 2025
Install new wiring, receptacles light fixtures in basement, bathroom, basement bedroom, and basement great room as per NEC2017. In stall (1) Circuit for A/C condenserCity of Philadelphia · 2025
Disconnect and reconnect the kitchen and appliances. (Existing wiring. ). Install 2 vanity sources (2) LED lighted mirrors, (2) GFCI Receptacles in primary bathroom (new wiring )City of Philadelphia · 2025
Install new circuits for kitchen (except fridge and dishwasher), 1st fl powder room, (1) 1st fl lighting, (1) 2nd fl primary bedroom, 3rd fl
Install recessed lights: (4) living room, (2) hall, (4) dining room, (6) kitchen, (4) primary bedroom, (4) family room, (2) bathroom
Install light fixtures: (1) exhaust powder room, (2) sconces powder room, (1) sconce kitchen, (1) exhaust fan bathroom,
Install receptacles as per NEC2017 in kitchen, 1st fl powder room, 3rd fl bathroom.
Install new 200 A service including meter socket, panel and grounding as per NEC2017City of Philadelphia · 2025
Install new 200 A service including new meter socket, panel and grounding as per NEC2017
Install (1) customer provided E.V. chargerCity of Philadelphia · 2025
INSTALL WIRING, LIGHTING, SWITCHES, EXHAUST FAN AND RECEPTACLES OUTLETS TO BATHROOM, BEDROOM AND HALLWAY. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC.City of Philadelphia · 2025
Fishing Only
House rewire to eliminate knob and tub wiring. Installation includes new Arc fault circuit breakers, new light fixtures, new receptacles and hard wired smoke/CO detectors as per NEC 2017.
3rd fl bathroom, 2nd fl bathroom, primary bedroom and kitchen are not part of this project.City of Philadelphia · 2025
Permitted projects on public record. Addresses are omitted for privacy.