What the public permit record shows, not self-reported reviews.
Is Green Tree Group Contracting, LLC a real contractor?
Green Tree Group Contracting, LLC appears in public building-permit records with 142 permits filed through 2022 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is Green Tree Group Contracting, LLC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to Green Tree Group Contracting, LLC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is Green Tree Group Contracting, LLC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. Green Tree Group Contracting, LLC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is Green Tree Group Contracting, LLC's work?
The most recent permit on record for Green Tree Group Contracting, LLC is dated 2022-12-12, with 142 permits on file in total.
FOR THE CONSTRUCTION OF AN ATTACHED STRUCTURE WITH CELLAR AND ROOF DEK ACCESSED BY A ROOF DECK ACCESS STRUCTURE.
FOR A TWO-FAMILY HOUSEHOLD LIVING. AS PER PLANS.
*******NO UNDERPINNING ON THIS APPLICATION. SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, MECH., OR ELECTRICAL WORK. *************City of Philadelphia · 2022
ALTERATION TO INCLUDE TENANT FIT-OUT FOR CHILDCARE CENTER IN VACANT COMMERCIAL SPACE AS PER APPROVED PLAN. NO WORK IS PROPOSED FOR THE EXISTING RESIDENTIAL UNITS.City of Philadelphia · 2022
NEW CONSTRUCTION OF A FOUR (4) STORY BUILDING WITH COMMON ROOF DECK AND PILOT HOUSES FOR USE AS A SHELL COMMERCIAL SPACE (USE REGISTRATION & FIT-OUT PERMITS REQUIRED PRIOR TO OCCUPANCY) AND FOURTEEN (14) DWELLING UNITS AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED AND INCLUDE STANDPIPES PER NFPA 14. FIRE WATCH REQUIRED PER DEPARTMENT CODE BULLETIN F-2001 *2018 IBC REVIEW*
**SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**City of Philadelphia · 2021
For underpinning of wall adjacent to existing foundation at 2250 N 2nd Street, as per plans; no other work on this permit; see CP-2020-002223 for associated building permit.City of Philadelphia · 2021
FOR THE CONSTRUCTION OF A THREE-STORY STRUCTURE WITH CELLAR AND PILOTHOUSE, TO ACCESS ROOF DECK, FOR A SINGLE-FAMILY DWELLING, AS PER APPROVED.City of Philadelphia · 2021
FOR NEW CONSTRUCTION OF A THREE (3) STORY WOOD-FRAME ATTACHED STRUCTURE ON REINFORCED CONCRETE FOOTINGS/FOUNDATIONS WITH A ROOF DECK AND ROOF DECK ACCESS STRUCTURE. FOR USE AS A SINGLE-FAMILY DWELLING THROUGHOUT. BUILDING SHALL BE FULLY SPRINKLERED (13D), SEPARATE PERMITS REQUIRED FOR ALL FIRE SUPPRESSION SYSTEMS. *PROTECTION OF RIGHT-OF-WAY / PEDESTRIANS / ADJACENT PROPERTIES REQUIRED DURING ALL CONSTRUCTION.*ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2015 IECC. PRIOR TO ISSUANCE OF C.O SUBMITTAL OF AIR BARRIER CHECKLIST AND ENVELOPE TESTING CERTIFICATE IS REQUIRED. BOTH TO BE COMPLETED BY AN APPROVED PARTY.
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you Green Tree Group Contracting, LLC?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to Green Tree Group Contracting, LLC's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2021
For the erection of a new three (3) story attached structure (w/roof deck and pilot house enclosing access stairs only), to be used as Group R-3 (single-family dwelling), as per plans; MEP work on associated sub-permits; building to be sprinklered throughout in accordance with NFPA 13D minimum; pedestrian protection required as per 2018 IBC Section 3306; see ZP-2020-007236 for zoning/use permit.City of Philadelphia · 2021
For the erection of a three-story attached structure per plans.City of Philadelphia · 2021
New construction of a 3-story single family structure with cellar, roof deck and deck access enclosureCity of Philadelphia · 2021
FOR NEW CONSTRUCTION OF A THREE (3) STORY WOOD-FRAME ATTACHED STRUCTURE ON REINFORCED CONCRETE FOOTINGS/FOUNDATIONS WITH A ROOF DECK AND ROOF DECK ACCESS STRUCTURE. FOR USE AS A SINGLE-FAMILY DWELLING THROUGHOUT. BUILDING SHALL BE FULLY SPRINKLERED (13D), SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS. *PROTECTION OF RIGHT-OF-WAY / PEDESTRIANS / ADJACENT PROPERTIES REQUIRED DURING ALL CONSTRUCTION.*ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2015 IECC. PRIOR TO ISSUANCE OF C.O SUBMITTAL OF AIR BARRIER CHECKLIST AND ENVELOPE TESTING CERTIFICATE IS REQUIRED. BOTH TO BE COMPLETED BY AN APPROVED PARTY.City of Philadelphia · 2021
FOR THE CONSTRUCTION OF AN ATTACHED STRUCTURE WITH CELLAR AND ROOF DECK ACCESSED BY A ROOF DECK ACCESS STRUCTURE. FOR A SINGLE FAMILY HOUSEHOLD LIVING. AS PER PLANS. ******NO UNDERPINNING ON THIS APPLICATION. SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, MECH., OR ELECTRICAL WORK.******************************************************************************************City of Philadelphia · 2021
FOR THE ERECTION OF A FOUR (4) STORY ATTACHED STRUCTURE AS PER APPROVED PLANS. FOR USE AS EIGHTEEN (18) DWELLING UNITS AND VACANT COMMERCIAL SPACE. STRUCTURE TO BE FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13. **SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.** **2018 IBC**AMENDED AS OF 7/16/2021 FOR THE ADDITION OF AN ELEVATOR.
*AMENDMENT TO CHANGE SPECIAL INSPECTION AGENCY AND DPRC.City of Philadelphia · 2020
Permitted projects on public record. Addresses are omitted for privacy.