What the public permit record shows, not self-reported reviews.
Is Gabriel S Polishuk, Inc. a real contractor?
Gabriel S Polishuk, Inc. appears in public building-permit records with 32 permits filed through 2025 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is Gabriel S Polishuk, Inc.'s track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to Gabriel S Polishuk, Inc. by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is Gabriel S Polishuk, Inc. licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. Gabriel S Polishuk, Inc. has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is Gabriel S Polishuk, Inc.'s work?
The most recent permit on record for Gabriel S Polishuk, Inc. is dated 2025-11-26, with 32 permits on file in total.
For the erection of an addition, that includes a roof deck and pilot house, and for interior and exterior alterations to an existing attached single-family dwelling per plans. Separate permits are required for all associated Mechanical, Electrical, and Plumbing work.City of Philadelphia · 2025
Permit amended on 12/4/25: Amendment due to unforeseen site conditions. Original facade found to be deteriorated and damaged; required rebuild of front facade at first and second floor, foundation to remain.
Interior renovation, rear addition, third floor addition w/ pilot house and roof deck on existing two-story, single-family rowhome. Interior work includes new stair from basement up to pilot house, lowered basement slab, new basement bathroom; first floor new kitchen; second floor new bathroom; third floor new bathroom. Basement to have egress window well at rear yard. Details as shown on the plan.City of Philadelphia · 2025
FOR THE ERECTION OF A THREE (3) STORY ATTACHED STRUCTURE OF TYPE V-B CONSTRUCTION WITH BASEMENT, ROOF DECK, AND ROOF DECK ACCESS STRUCTURE (HEIGHT NTE 38 FEET FROM GRADE). FOR USE AS A SINGLE-FAMILY DWELLING (GROUP R-3). BUILDING TO BE FULLY SPRINKLERED WITH A MINIMUM OF A NFPA 13D AUTOMATIC SPRINKLER SYSTEM. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IRC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, FIRE SUPPRESSION WORK, AND EXCAVATION WORK GREATER THAN 5 FEET BELOW ADJACENT GRADE. ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O., SUBMITTAL OF AIR BARRIER CHECKLIST AND ENVELOPE TESTING CERTIFICATE IS REQUIRED. BOTH TO BE COMPLETED BY AN APPROVED PARTY.City of Philadelphia · 2025
FOR NEW CONSTRUCTION OF AN THREE-STORY ATTACHED STRUCTURE WITH CELLAR, ROOF DECK AND ROOF DECK ACCESS STRUCTURE FOR USE AS A TWO-FAMILY HOUSEHOLD LIVING. BUILDING TO BE FULLY SPRINKLERED WITH NFPA 13D MINIMUM. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION.City of Philadelphia · 2025
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you Gabriel S Polishuk, Inc.?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to Gabriel S Polishuk, Inc.'s website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
FOR THE ERECTION OF AN ATTACHED THREE STORY STRUCTURE FOR USE AS A SINGLE FAMILY HOUSEHOLD LIVING. BUILDING TO BE SPRINKLERED IN ACCORDANCE WITH NFPA 13D. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. **A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 10 FEET OF THE BUILDING FACADE IN ACCORDANCE WITH SECTION 3306 OF THE 2018 IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMIT REQUIRED PRIOR TO THE START OF ANY WORK.** BLOWER DOOR TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ASTM E 779 OR ASTM E 1827 BY AN APPROVED THIRD PARTY AGENCY
**EXCAVATION PERMIT REQUIRED**City of Philadelphia · 2025
FOR THE CONSTRUCTION OF A THREE (3) STORY LIGHT-FRAMED ATTACHED STRUCTURE TO BE SPRINKLERED IN ACCORDANCE WITH NFPA 13D THROUGHOUT. FOR USE AS A SINGLE-FAMILY DWELLING. ALL WORK TO BE DONE AS PER APPROVED PLANS AND IN ACCORDANCE WITH THE 2018 IRC. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. *SEPARATE PERMIT REQUIRED FOR FIRE SUPPRESSION WORK.* *A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN TEN (10) FEET OF THE BUILDING FACADE IN ACCORDANCE WITH SECTION 3306 OF THE 2018 IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMIT REQUIRED PRIOR TO THE START OF ANY WORK.* *BLOWER DOOR TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ASTM E 779 OR ASTM E 1827 BY AN APPROVED THIRD PARTY AGENCY.*City of Philadelphia · 2025
NEW CONSTRUCTION OF A THREE STORY PLUS MEZZANINE BUILDING WITH A ROOF DECK (ACCESS VIA UNENCLOSED EXTERIOR STAIRWAY) FOR USE AS A SHELL COMMERCIAL SPACE (USE REGISTRATION & FIT-OUT PERMITS REQUIRED PRIOR TO OCCUPANCY) AND ONE (1) DWELLING UNIT AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED PER NFPA 13. *2018 IBC REVIEW*
**SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**City of Philadelphia · 2023
MAKE SAFE PERMIT TO COMPLY WITH CF-2022-005799 TO INCLUDE REPAIRS/REPLACEMENT TO FRONT/REAR WALLS, REAR BAY, ROOF/FLOOR JOISTS AND STAIRWAYS PER APPROVED PLANS, ENGINEER'S REPORT AND IN ACCORDANCE WITH CODE BULLETIN PM-1801. LICENSED PA PROFESSIONAL ENGINEER IS REQUIRED TO MONITOR REPAIRS MADE UNDER THIS PERMIT. THE ENGINEER MUST SUBMIT A SEALED STATEMENT TO THE DEPARTMENT CONFIRMING THAT THE STRUCTURE IS IN SOUND CONDITION AT COMPLETION. SEPARATE PERMITS REQUIRED FOR ADDITIONAL ALTERATIONS NOT ADDRESSED IN APPROVED PLANS.City of Philadelphia · 2022
NEW 3-STORY SINGLE FAMILY DWELLING WITH BASEMENT, PILOT HOUSE AND ROOF DECKCity of Philadelphia · 2022
FOR UNDERPINNING OF EXISTING BASEMENT AS PER PLANS.City of Philadelphia · 2022
FOR THE ERECTION OF A THREE STORY ATTACHED STRUCTURE FOR USE AS A SINGLE FAMILY HOUSEHOLD LIVING. STRUCTURE HAS A ROOF DECK ACCESSED BY A ROOF DECK ACCESS STRUCTURE. STRUCTURE TO BE FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13D. SIZE AND LOCATION AS SHOWN PER APPLICATION/PLAN. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. [AIR BARRIER AND INSULATION TESTING REPORTS TO BE PROVIDED TO THE INSPECTOR FOR TESTING COMPLIANCE REQUIREMENTS. FINALIZED HVAC EQUIPMENT DESIGN DOCUMENTATION TO BE SUBMITTED WITH MECHANICAL PERMIT DOCUMENTATION.] **A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 9 FEET OF THE BUILDING FACADE IN ACCORDANCE WITH SECTION 3306 OF THE 2018 IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMIT REQUIRED PRIOR TO THE START OF ANY WORK.***SEPARATE PERMITS REQ'D FOR ANY ELECTRICAL, PLUMBING, MECHANICAL, AND FIRE SUPPRESSION SYSTEM INSTALLATIONS.City of Philadelphia · 2022
For the erection of an attached structure with 2 roof decks, 2 roof access structures and 1 rear deck accessed through third floor. For use as three dwelling units and Vacant Commercial Space occupying street frontage to a depth of 30 ft (separate use and fit-out permits required). Building to be fully sprinklered. Separate permits required for MEP & FP work.City of Philadelphia · 2021
Permitted projects on public record. Addresses are omitted for privacy.