FOR THE AMENDEMENT OF PREVIOUSLY APPROVED PERMIT #763660 FOR THE REMOVAL OF REAR WALL, AND BREEZE WAY WALL OF THE FRONT HOUSE, WORK TO INCLUDE THE REMOVAL AND REPLACEMENT OF JOISTS THROUGHOUT. WORK TO ALSO INCLUDE THE DEMOLITION OF REAR ONE STORY GARAGE. ENSURE PEDESTRIAN PROTECTION IS IN PLACE PRIOR TO THE START OF ANY. ALL WORK TO BE DONE PER APPROVED PLANS. A TEMPORARY WOOD FRAME WALL SHALL BE CONSTRUCTED TO SEAL THE SALVAGED FRONT SECTION. IF FIELD CONDITIONS VARY CONTACT STRUCTURAL ENGINEER PRIOR TO THE START OF ANY WORK. ORIGINAL PERMIT APPROVED FOR LEVEL II ALTERATIONS TO AN EXISTING VACANT STRUCTURE, ALTERATIONS TO INCLUDE THE REPAIR OF FRONT BRICK FACADE WITH STAR BOLTS AND PROVIDE SHORING THROUGHOUT THE STRUCTURE ONLY AS SHOWN PER DETAILS. ALL OTHER ALTERATIONS REFERENCED IN ENGINEERS REPORT TO OBTAIN SEPARATE PERMITS AS REQUESTED. ENGINEER TO BE ON SITE AT ALL TIMES. ALL WORK TO BE DONE PER SEALED DETAILS. IF FIELD CONDITIONS VARY CONTACT STRUCTURAL ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.City of Philadelphia · 2017
EZ PERMIT STANDARD ALTERATIONS - FOR ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING AS PER ATTACHED STANDARD - FOR ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS. WORK TO INCLUDE ALTERATIONS THROUGHOUT, KITCHEN, BATHROOM, HARDWOOD FLOORS, GWB TAPED & FINISHED, PAINTING THROUGHOUT AS PER THE ATTACHED STANDARD. SEPARATE PERMITS REQUIRED FOR PLUMBING, ELECTRIC AND HVAC.
CALL INSPECTOR AT DISTRICT OFFICE AT LEAST 24 HOURS PRIOR TO STARTING WORK.City of Philadelphia · 2017
EZ PERMIT STANDARDS ALTERATIONS- FOR ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.City of Philadelphia · 2017
FOR INTERIOR ALTERATIONS ON THE SECOND FLOOR OF AN EXISTING STRUCTURE TO INLCUDE NEW INTERIOR PARTITIONS AND INTERIOR FINISHES, AS PER APPROVED PLANS. THIS PERMIT REPLACES EXPIRED PERMIT #635008.
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
REPAIRES AS PRESCRIBED IN SUBMITTED ENGINEER REPORT. REMOVAL AND RECONSTRUCTION OF REAR WALL. REPLACEMENT OF JOISTS AND RAFTERS (NOT TO EXCEED 2/3.) PERMIT DELIEVERED FROM DOWNSTAIRS 9/5/17.City of Philadelphia · 2017
FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE FOR THE USE OF AN ASSEMBLY AND ENTERTAINMENT. WORK TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS PER BBS VARIANCE CASE #30757. ***PER ZBA CASE 24241, 3 YEAR TEMPORARY USE***IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMTIS REQUIRED FOR ALL OTHER WORK.City of Philadelphia · 2017
NO CHANGE IN OCCUPANCY; INTERIOR ALTERATIONS PER PLANS INCLUDING RELOCATION OF BATHROOM TO CREATE FULLY ACCESSIBLE UNISEX BATHROOM, RELOCATION OF BAR AND ASSOCIATED FINISHES; MINOR PARTITION WORK AT FRONT/CENTER BEDROOMS IN SECOND FLOOR DWELLING UNIT. SEPARATE PERMITS REQUIRED FOR ANY MECHANICAL, ELECTRICAL OR PLUMBING WORK (SEE LAVATORY PLACEMENT NOTATION).City of Philadelphia · 2017
EXITING FRONT PORCH-REPLACE PORCH FLOOR 3/4 PLYWOOD EXTERIOR. REPLACE PROCH RAIL, HIGH W/STEP RAIL. INSTALL NEW PORCH ROOF COVER W/ GUTTER & DOWN SPOUT.City of Philadelphia · 2017
MAKE SAFE PERMIT -REPLACE FRONT WALL WITH 12" MASONRY AS PER ENGINEERS REPORT. TO RESOLVE CASE #573380. ABUTTING SIDEWALK MUST BE CLOSED WITH FENCING A MINIMUM OF 6’ IN HEIGHT. SEPARATE STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CASE #573380.REPLACE FRONT WALL WITH 12" MASONRY TO MAKE SAFE FROM ENGINEERS REPORT. SEE APP# 766862 FOR ENGINEER'S REPORT/PLANS.City of Philadelphia · 2017
MAKE SAFE PERMIT -REPLACE FRONT WALL WITH 12" MASONRY AS PER ENGINEERS REPORT. TO RESOLVE CASE #573362. ABUTTING SIDEWALK MUST BE CLOSED WITH FENCING A MINIMUM OF 6’ IN HEIGHT. SEPARATE STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CASE #573362.REPLACE FRONT WALL WITH 12" MASONRY TO MAKE SAFE FROM ENGINEERS REPORTCity of Philadelphia · 2017
EZ PERMIT STADARD ALTERATIONS- FOR ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.City of Philadelphia · 2017
FOR THE ERECTION OF A THREE (3) STORY STRUCTURE FOR USE AS TWO (2) FAMILY DWELLINGS WITH ROOF DECK AND PILOT HOUSE AND A CELLAR. STRUCTURE TO BE FULLY SPRINKLERED PER NFPA 13R MIN. SEPARATE PERMITS REQUIRED FOR PLUMBING, MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 9 FEET OF BUILDING FAÇADE IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMITS ARE REQUIRED.City of Philadelphia · 2017
Permitted projects on public record. Addresses are omitted for privacy.