TANK REMOVAL PERMIT - REMOVAL OF ONE 6,000 GALLON HEATNG OIL UNDERGROUND STORAGE TANK (UST) REMOVE ANY PETROLEUM PRODUCT/WATER FROM TANK, CLEAN TANK, CONDUCT A CONFIRMATORY SOIL SAMPLING OF SURROUNDING SOIL. CONTIGENCY PLAN IN PLACE IN THE CASE CONTAMINATED SOILS DISCOVERED AND BACKFILL. ALL WORK COMPLETED IN ACCORDANCE WITH PADEP UST REMOVAL GUIDELINES. PROVIDE SCHOOL DISTRICT OF PHILADELPHIA AND THE DEPARTMENT OF LICENSES AND INSPECTIONS OF THE CITY OF PHILADELPHIA WITH A TANK CLOSURE REPORT.City of Philadelphia · 2019
REMOVAL OF 1 2,000 GALLON UNDERGROUND HEATING OIL STORAGE TANK. SOIL SAMPLES WILL BE COLLECTED PER PA DEP REGULATIONS. CLOSURE REPORT WILL BE SUBMITTED TO THE CITY OF PHILA AND UNIVERSITY OF PA.
. THE REMOVAL MUST COMPLY WITH THE REGULATIONS OF THE PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION (PADEP).City of Philadelphia · 2019
REMOVAL OF 1 600 GALLON UNDERGROUND DIESEL STORAGE TANK. SOIL SAMPLES WILL BE COLLECTED PER PA DEP REGULATIONS. A TANK CLOSURE REPORT WILL BE SUBMITTED TO THE CITY OF PHILA AND SEPTA.
. THE REMOVAL MUST COMPLY WITH THE REGULATIONS OF THE PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION (PADEP).City of Philadelphia · 2019
REMOVAL OF (1) 5,000 GALLON UNDERGROUND HEATING OIL STORAGE TANK PER PA DEP REGULATIONS. SAMPLES WILL BE COLLECTED AND A TANK CLOSURE REPORT PROVIDED TO CITY OF PHILADELPHIA AND OWNER.City of Philadelphia · 2018
REMOVE (2) TWO (275 GALLON) UNDERGROUND STORAGE TANKS. THE REMOVAL MUST COMPLY WITH THE REGULATIONS OF THE PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION (PADEP)City of Philadelphia · 2018
REMOVAL OF (1) 3,000 GALLLON HEATING OIL UNDERGROUND STORAGE TANK - THE REMOVAL MUST COMPLY WITH THE REGULATIONS OF THE PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION (PADEP).
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2018
REMOVAL OF (1) 10,000 GALLON HEATING OL ABOVE GROUND TANK _ THE REMOVAL MUST COMPLY WITH THE REGULATIONS OF THE PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION (PADEP).City of Philadelphia · 2018
REMOVAL OF ONE 500 GALLON UST FORMALLY USED TO STORE #2 HEATING OIL UNDER SIDEWALK, BACKFILL WITH CONCRETE SLURRY PER PADEP REGULATIONS. PROVIDE CLOSURE REPORT TO INSPECTOR.City of Philadelphia · 2018
REMOVE (3) THREE UNDERGROUND STORAGE TANKS. (1) ONE 500 GALLON AND (2) TWO 5000 GALLON TANKS. THE REMOVAL MUST COMPLY WITH THE REGULATIONS OF THE PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION. (PADEP)City of Philadelphia · 2017
CLOSE IN PLACE (1) ONE 6,000-GALLON UNDERGROUND STORAGE TANK.THE REMOVAL MUST COMPLY WITH THE REGULATIONS OF THE PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION. (PADEP)City of Philadelphia · 2017
REMOVAL OF ONE 1,000 GALLON HEATING OIL UNDERGROUND STORAGE TANK FOLLOWING ALL PA DEP REGULATIONS WITH SOIL SAMPLING AND A CLOSURE REPORT DOCUMENTING ALL FINDINGSCity of Philadelphia · 2017
REMOVAL OF (6) SIX 1,000 GALLON GASOLINE UNDERGROUND STORAGE TANKS ACCORDING TO PA DEP REGULATIONS SOIL SAMPLING AND CLOSURE REPORTCity of Philadelphia · 2017
Permitted projects on public record. Addresses are omitted for privacy.