What the public permit record shows, not self-reported reviews.
Is ELECTRACOM INCORPORATED a real contractor?
ELECTRACOM INCORPORATED appears in public building-permit records with 105 permits filed through 2025 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is ELECTRACOM INCORPORATED's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to ELECTRACOM INCORPORATED by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is ELECTRACOM INCORPORATED licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. ELECTRACOM INCORPORATED has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is ELECTRACOM INCORPORATED's work?
The most recent permit on record for ELECTRACOM INCORPORATED is dated 2025-11-13, with 105 permits on file in total.
Furnishing and installing a new fire alarm control panel and new fire alarm devices and equipment. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,22016 NFPA-72.
**SEPARATE ELECTRICAL PERMITS REQ'D FOR INTERIOR WIRING**City of Philadelphia · 2025
Renovate an old X-Ray Room to accept new X-Ray equipment and a new X-Ray machine as per 2017 NEC.City of Philadelphia · 2025
Electrical work in new Fluoroscopy X-Ray Room ,panel , relocate fire alarm notification appliance ,lighting ,receptacles ,ethernet cable, on the Ground Floor of the Levy Building at Einstein Medical Center Philadelphia. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.City of Philadelphia · 2025
Renovation of the existing Radiology Reading Room to upgrade the lighting and power in the area to accommodate new desks and equipment using the existing circuiting. Provide power for the new mechanical & hvac equipment using the existing circuiting. All work in accordance with the 2017 nec.
** THE CONTRACTOR WILL AMEND THI.S PERMIT TO INCLUDE THE FIRE ALARM WORK WHEN THE VENDOR FIRE ALARM PLANS BECOME AVAILABLECity of Philadelphia · 2023
Furnish and install hospital grade Type MC cable from the existing panels to the locations of the new receptacles as detailed on the drawings. Furnish and install hospital grade Type MC cable from the existing panels to the locations of the new light fixtures as detailed on the drawings. Furnish and install the specified light fixtures at the locations shown on the drawings as per 2017 NEC.City of Philadelphia · 2020
Remove the existing light fixtures and replace with new LED light fixtures and new lighting controls. Extend the existing hospital -grade wiring to the locations of the new receptacles as shown on the drawings. Relocate one fire alarm strobe. Existing lighting and power circuits to be resused.
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you ELECTRACOM INCORPORATED?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to ELECTRACOM INCORPORATED's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2020
INSTALL NEW 100AMP SERVICE ENTRANCE CABLE,METER SOCKET,NEW PANEL AND WIRE TO INSTALL 8-RECEPTS AND 3-LIGHT FIXTURES IN NEW ADDITION AS PER 2014 NEC (EAST DISTRICT)City of Philadelphia · 2019
INSTALL 6 NEW HORN/STROBE DEVICES AT THE LOCTAIONS SHOWN ON THE DRAWINGS. INSTALL A NEW NAC CIRCUIT FOR THE NEW HORN/STROBES FROM THE EXISTING NAC POWER PANEL AS PER NFPA 72 (CC DIST)City of Philadelphia · 2019
FURNISH & INSTALL MC TYPE CABLE FROM EXISTING ELECTRICAL PANEL TO LOOCATION OF NEW RECEPTACLES, INSTALL NEW DIMMING PANEL, FURNISH & INSTALL MC TYPE CABLE FROM NEW DIMMING PANEL TO LOCATIONS OF THE LIGHT FIXTURES AS PER NEC 2017City of Philadelphia · 2019
FURNISH AND INSTALL MC TYPE CABLE FROM THE EXISTING PANELS TO THE LOCATIONS OF THE LIGHT FIXTURES AND RECEPTACLES THROUGHOUT THE STORE AS SPECIFIED ON THE DRAWINGS. STORE IS TO BE A DOLLAR TREE STORE.City of Philadelphia · 2019
REPLACE EXISTING LIGHT FIXTURES WITH NEW LED FIXTURES, INSTALL NEW RECEPTACLES & RECEPTACLES SHALL BE FED FROM EXISTING CIRCUITS IN OFFICE AREA AS PER NEC 2017 NORTH DISTRICTCity of Philadelphia · 2019
FURNISH & INSTALL TYPE MC CABLING FROM THE LOCATION OF THE EXISTING CIRCUITS TO THE LOCATIONS OF THE POWER RECEPS LIGHT FIXTURES AS DETAILED ON THE DRAWINGS REPLACE EXISTING POWER PANELS AS SPECIFIED ON THE DRAWINGS PER 2008 NECCity of Philadelphia · 2019
Permitted projects on public record. Addresses are omitted for privacy.