What the public permit record shows, not self-reported reviews.
Is EAST COAST REMODELING INC a real contractor?
EAST COAST REMODELING INC appears in public building-permit records with 15 permits filed through 2011 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is EAST COAST REMODELING INC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to EAST COAST REMODELING INC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is EAST COAST REMODELING INC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. EAST COAST REMODELING INC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is EAST COAST REMODELING INC's work?
The most recent permit on record for EAST COAST REMODELING INC is dated 2011-12-19, with 15 permits on file in total.
INSTALL 4 INCH BRICK VENEER TIED BACK TO EXISTING MASONRY WALLS, FRONT AND SIDE. AS PER APPROVED PLAN. NO CHANGE IN SIZE OR LOCATION OF WINDOWS AND DOORS. REMOVAL AND REBUILD OF EXISTING WALLS OR REPLACEMENT OF EXISTING STOREFRONT IS NOT ALLOWED UNDER THIS PERMIT.
INSTALL 4 INCH BRICK VENEER ON NEW CONCRETE FOOTING IN FRONT OF EXISTING MASONRY WALL AS PER 2009 IRC 703.7. MAXIMUM HEIGHT: 30 FEET ABOVE FOUNDATION. MAXIMUM THICKNESS 5 INCHES. WINDOW AND DOOR OPENINGS SAME SIZE/LOCATION. NEW CONCRETE FOOTING TO BE BELOW FROST LINE, (30 INCHES). NEW WALL SHALL BE ANCHORED TO SUPPORTING WALL WITH CORROSION-RESISTANT METAL TIES 24 INCHES ON CENTER HORIZONTALLY AND VERTICALLY. PROVIDE 1 INCH AIR SPACE BETWEEN WALLS. PROVIDE WEEP HOLES AND FLASHING ABOVE WINDOW AND DOOR OPENINGS. PROVIDE CAPPING, FLASHING AND CAULKING AT TERMINATION OF WALL TO PREVENT WATER INFILTRATION.
AN INSPECTION OF EXISTING WALL TO BE SCHEDULED WITH INSPECTOR BEFORE WORK STARTS.City of Philadelphia · 2011
REMOVE AND REPLACE COMMERCIAL COOKING EXHAUST SYSTEM TO MAKE CODE COMPLIANT.City of Philadelphia · 2011
INTERIOR RENOVATION TO AN EXISTING TAKE-OUT RESTAURANT. NO CHANGE OF OCCUPANCY.City of Philadelphia · 2011
FOR THE ALTERATIONS TO FIT-OUT AN EXISTING SPACE ON THE FIRST FLOOR TO CREATE A TAKE OUT RESTAURANT. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. THIS WORK ACTIVITY SHALL BE PERFORMED BY A CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.City of Philadelphia · 2011
FOR THE INSTALLATION OF A KITCHEN EXHAUST SYSTEM TO INCLUDE A WALL HOOD AND ASSOCIATED DUCTWORK. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. THIS WORK ACTIVITY SHALL BE PERFORMED BY A CONTRACTOR LICENSE BY THE CITY OF PHILADELPHIA. A SEPARATE PERMIT IS REQUIRED FOR THE INSTALLATION OF A COMMERCIAL KITHCHEN EXTINGUISHING SYSTEM.
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you EAST COAST REMODELING INC?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to EAST COAST REMODELING INC's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2011
INTERIOR RENOVATIONS FOR RESTAURANT AS PER PLANS.City of Philadelphia · 2011
CONSTRUCTION OF AN EXTERIOR RAMP TO CREATE AN ACCESSIBLE ENTRANCE AND REPLACEMENT WINDOWS IN EXISTIG ROUGH OPENINGS.
THIS PERMIT IS NOT A CERTIFICATE OF OCCUPANCY NOR IS IT AN APPROVAL OF ANY USE FOR THE 1ST FLOOR.City of Philadelphia · 2011
INSTALL NEW HANDICAP ACCESSIBLE BATHROOM, INSTALL HANDICAP ACCESSIBLE SERVICE COUNTER AND CLOSE-OFF STAIRWAY TO UPPER FLOOR ONLY AS PER PLAN. SEPARATE USE REGISTRATION PERMIT AND CERTIFICATE OF OCCUPANCY PERMIT REQUIRED.City of Philadelphia · 2011
APPLY CERAMIC TILES VENEER TO EXISTING FRONT WALL WITH BASE OF WIRE LATH SECURED TO STRUCTURE.City of Philadelphia · 2011
APPLY CERAMIC TILES VENEER TO THE EXISTING FRONT WALL WITH BASE OF WIRE LATH SECURED TO STRUCTURE.City of Philadelphia · 2011
ALTERATION AND RENOVATION TO AN EXISTING 3 STORY SFD WITH AND ADDITION.City of Philadelphia · 2010
ALTERATION AND RENOVATION TO AN EXISTING 3 STORY SFD WITH AND ADDITION.City of Philadelphia · 2010
Permitted projects on public record. Addresses are omitted for privacy.