What the public permit record shows, not self-reported reviews.
Is EARL HOOKS a real contractor?
EARL HOOKS appears in public building-permit records with 126 permits filed through 2010 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is EARL HOOKS's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to EARL HOOKS by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is EARL HOOKS licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. EARL HOOKS has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is EARL HOOKS's work?
The most recent permit on record for EARL HOOKS is dated 2010-08-06, with 126 permits on file in total.
20-120V RECEPTACLES 8-WALL SWITCHES 16-CEILING LIGHTS 4-GFI RECEPTACLE (PER 2008 NEC CODE)(WEST DIST)City of Philadelphia · 2010
REPLACE FAULTY UNDERGROUND 200 AMP SERVICE 200AMP 40 AMP PANEL 40CIRCUIT PANEL, AND 30 CIRCUIT PANEL(PER 2008 NEC CODE)(WEST DIST)City of Philadelphia · 2010
FIRE ALARM PANEL, 4 SMK DET, 1 HEAT DET,5 PULL STATION,9 STROBE HORNS,7 STROBE AS PER NFPA 72. ELECTRIC REPLACE EXISTING 100AMP PANEL, 20 RECEPTACLES,22 CEILING LIGHTS,15 EMEGENCY LTS, 5 EMER/EXITS,2 LIGHTS AS PER 2005 NEC (NORTH DISTRICT)City of Philadelphia · 2010
REPLACE LINE FEED CABLE TO METER. REPLACE 12CRKT BRAKER PANEL TO 20CRKT PANEL)20 CRKT G.F.)1 LINE FOR KIT)2 SWITCHES AND CEILING LIGHT IN SHED KITCHEN, 2 OUTSIDE LIGHTS.PER 2008 NEC CODECity of Philadelphia · 2010
200 AMP SERVICE LOAD, 30 CIRCUIT, (40) 120 VOLT RECEPTACLES, (7) GFI RECEPTACLES, BREAKER PANEL, (40) CEILING LIGHTS, (20) WALL SWITCHES,
(2) EXHAUST FANS, (1) GARBAGE DISPOSAL, (4) OUTSIDE LIGHTS,(1) 220 VOLT, 30 AMP CIRCUIT AS PER 2008 NEC (NORTH DIST)City of Philadelphia · 2010
(4 ZONE FA PANEL),SMOKE DTRS,PULL STATIONS,STROBE HORNS,3 EMERGENCY/EXIT LIGHTS,3 REMOTE HEADS,2 EMERGENCY LIGHTS,3 RECEPTACLES,REPLACE FAULTY LIGHTS,REPLACE 200 AMP BREAKER PANEL ALL AS PER NFPA-72 (SOUTH DIST)
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you EARL HOOKS?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2010
200 AMP SERVICE, 1 METER PANEL, 5 GFI RECPT, 15 CEILING LIGHTS, 35 GEN PURPOSE RECEPT, 10 CRKT LINES, 13 WALL SWITCHES, 4 ARK FAULT BREAKER AS PER 2008 NEC (NORTH DISTRICT)City of Philadelphia · 2010
200AMP SERVICE, 20 125V RECEPT, 3 GFI, 2 ARK FAULT BREAKER, 2 OUTSIDE LIGHTS, 40 CEILING LIGHTS, 9 SWITCHES AS PER 2008 NEC (SOUTH DISTRICT)City of Philadelphia · 2010
RECONNECTING (3) SMOKE DETECTORS, (2) HORNS, (2) PULL STATIONS PER 2008 NECCity of Philadelphia · 2010
(2) 120 VOLT RECEPTACLES, (4) CEILING LIGHTS, (1) WALL SWITCH AS PER 2008 NEC (EAST DIST)City of Philadelphia · 2010
200 AMP METER PANEL, 40 CIRCUIT BREAKER PANEL, GROUND ROD AND GROUND WIRING AS PER 2008 NEC (WEST DIST)City of Philadelphia · 2010
Permitted projects on public record. Addresses are omitted for privacy.