What the public permit record shows, not self-reported reviews.
Is DAVID NGUYEN a real contractor?
DAVID NGUYEN appears in public building-permit records with 72 permits filed through 2026 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is DAVID NGUYEN's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to DAVID NGUYEN by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is DAVID NGUYEN licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. DAVID NGUYEN has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is DAVID NGUYEN's work?
The most recent permit on record for DAVID NGUYEN is dated 2026-04-13, with 72 permits on file in total.
Install two (2) dedicated branch circuits for:
Kitchen exhaust hood fan
Make-up air unit
Install and/or extend branch circuit(s) for kitchen hood lighting, including all required switching and controls
Provide all wiring, conduit, fittings, and terminations required to connect:
Exhaust fan
Make-up air unit
Lighting fixturesCity of Philadelphia · 2026
FOR INTERIOR ALTERATIONS TO AN EXISTING ATTACHED STRUCTURE USED AS A SINGLE-FAMILY DWELLING AS PER BUILDING APPLICATION/PLAN.City of Philadelphia · 2026
interior rough wires only
rough in wires for the whole house
please see contract
fish wires and use conduitCity of Philadelphia · 2025
INSTALL A 400 AMP SERVICE, (4) GANG METER BANK, (1) 200 AMP PANEL & FEEDER, (3) 125 AMP PANELS & FEEDERS. INSTALL WIRING THROUGHOUT THE COMMON AREAS, COMMERCIAL SPACE & TWO DWELLING UNITS. INSTALL LIGHTS NORMAL & EMERGENCY, SWITCHES, SENSORS, RECEPTACLES & SMOKE ALARMS. PROVIDE POWER FOR THE MECHANICAL & HVAC EQUIPMENT. INSTALL A NEW FIRE ALARM SYSTEM THROUGHOUT. ALL WORK IN ACCORDANCE WITH THE 2017 NEC.City of Philadelphia · 2024
Install 400 amp service, rough wire, and finish as per 2017 NEC. Install fire alarm system according to plans and 2016 NFPA 72.City of Philadelphia · 2024
Rough in and Finish
Install A new 200-amp service
1-100-amp sub-panel on 2nd floor
Switches 51
Recessed lights 71
Receptacle 61
2- 30 for Havc
6 smoke/carbon
5 smokes
Washer and dryer
All circuits are to be installed with AFCI or GFCI protection where required.
No we are not make this a 2 family use.
Adding a sub-panel on 2nd floor for lighting and Receptacles
So we don’t have to run long home run to the main panel.
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you DAVID NGUYEN?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2024
we will have to fish wires to the location, using conduits/wiremold
New Circuit is to be installed in each room/area including AFCI
protection where required for safety.
Front bedroom circuit: Front bedroom x 3 rewirings 2 existing adding 1 for better
safety code compliance, the left side of the front left window.
Middle bedroom circuit: x 3 rewiring existing 2, adding 1 to
better meet code standards.
Remove 1 outlet in the hallway
Rear bedroom circuit: x 2 rewire existing location add 1 near
entry door for better code compliance.
Living room circuit: x 2 rewire 2 front living room outlets
Dining room circuit: x 2 rewire 2 of the 3 outlets
Kitchen: 2 rewire the counter location between the
basement and dining room, install correct GFCI device and
rewire the outlet behind the gas range. Rear exterior outlet:
Rewire the rear exterior outlet
location and install the proper wet location GFCI device
and in use cover.
Mudroom x 1 outlet rewire the wall outlet to the left of
the closets.
Install faceplates: Install cover plates where needed to the
outlet and exposed switch/ceiling box locations
throughout the basement at no additional charge during
this rewires.
New Wiring for Light and Switch to be installed to rewire
existing location, relocate or add, including fixture support box
and installation of owner-provided fixture or reinstallation of
existing fixture, as detailed below:
Hallway closet rewire the pull-chain light location
Front exterior switch and light location
Replacement main service cable 100 amp:
Replace 100 amp outside service entrance cable with electrical
Service connection to the power grid max 25 feet above ground.
Install two ground rods 6 feet apart.
Bond the panel to the main water service at the entry
location to the building with unbroken green #6
grounding cable.
Install a jumper cable around the water meter.
Add an inter-system grounding bar by the panel for other
Utilities-
Do aCity of Philadelphia · 2024
House rewires.
Replace devices
and install hardwired smoke detectors.
Install recessed lights Add GFCI to kitchen, bathroom, and Laundry area.City of Philadelphia · 2024
Installing a fire alarm system according to plan and 2016 NFPA 72.City of Philadelphia · 2024
FOR THE ERECTION OF A THIRD FLOOR ADDITION WITH ROOF DECK AND ROOF ACCESS STRUCTURE ABOVE AN EXISTING ATTACHED STRUCTURE AS PER APPROVED PLAN.
*SEPARATE PERMITS REQUIRED FOR ELECTRICAL, PLUMBING, AND MECHANICAL WORK*
**UNDERPINNING IS NOT PART OF THIS PERMIT**City of Philadelphia · 2024
2 countertop 20-amp circuits,
1 20-ampcircuit for garbage disposal and dishwasher.
40-amp line for stove
20-amp line for microwave.
15-amp circuit for lighting.
20-amp line for refrigerator/2 weatherproof GFCI
4 4-inch led recessed.
2 Exterior lights
5 switches.
Add 2 additional outlets for the 2nd floor back bedroom.
All new circuit will added to an existing 200-amp panel.City of Philadelphia · 2024
Electrical Permit for combo RP-2023-006465City of Philadelphia · 2024