Is CURRENT ELECTRICAL SOLUTIONS a real contractor?
CURRENT ELECTRICAL SOLUTIONS appears in public building-permit records with 150 permits filed through 2026 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is CURRENT ELECTRICAL SOLUTIONS's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to CURRENT ELECTRICAL SOLUTIONS by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is CURRENT ELECTRICAL SOLUTIONS licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. CURRENT ELECTRICAL SOLUTIONS has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is CURRENT ELECTRICAL SOLUTIONS's work?
The most recent permit on record for CURRENT ELECTRICAL SOLUTIONS is dated 2026-05-12, with 150 permits on file in total.
Provide 125-amp panel feeders, new electrical panel, transformer, new light fixtures, exit signs, emergency wall-packs and select demo as needed. Power wiring and disconnects for rooftop hvac units. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.
**NO FIRE ALARM ON THIS PERMIT**City of Philadelphia · 2026
Installing 11 Dual Category 6 data locations, 6 Single Category 6 locations and reuse/relocate 12 existing dual locationCity of Philadelphia · 2026
INSTALL TWO PREACTION SYSTEM FOR SUBSTATION B-10 AND B-13. INSTALL HEAT DETECTORS IN AREA AND CONNECT THE PREACTION SYSTEMS TO THE FIRE ALARM SYSTEM. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA AND PER PLANS.City of Philadelphia · 2025
INSTALL CLEAN AGENT SPO SYSTEM AND ONE PRE ACTION SYSTEM. CONNECT BOTH SYSTEMS TO THE FIRE ALARM SYSTEM. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA 72 AND PER PLANS.City of Philadelphia · 2025
Installation of 2 low-voltage pre-action systems for 2nd & 3rd floor electrical rooms as per 2016 NFPA 72. 120v Power to panels and/or equipment provided by others.City of Philadelphia · 2025
Provide labor & material to install SHP PRO/
PRE-Action/ Clean Agent system as per drawings 1,2 and equipment
counts dated 12/17/24 ad 2016 NFPA 72.
AMENDMENT: Drawings were revised by customer to reflect a room layout change.City of Philadelphia · 2025
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you CURRENT ELECTRICAL SOLUTIONS?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to CURRENT ELECTRICAL SOLUTIONS's website. It links to this profile so homeowners can see the public permit record behind your work.
Furnish material and labor to install red EMT conduit
systems and SSI supplied equipment & devices as per drawings dated 11/10/23 for
replacement of fire alarm system. Use
existing system to be removed in its entirety up to 80% depending on device
locations we cannot access to remove. Demo various modules not listed on
drawings .Provide 120-volt AC power for new panel location. Demo existing 120-volt. ALL WORKM IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.
AC power from existing system.Provide two 120-volt AC power for new Vesda power
supplies. Demo existing 10Volt AC power from existing supplies. Patch duct where
existing duct detectors were removed. All work is to be done according to approved drawings-2017 nec,2016 nfpa-72.
City of Philadelphia · 2025
INSTALL NEW LIGHTS NORMAL & EMERGENCY, & SWITCHES CONNECTED TO THE EXISTING CIRCUITS. INSTALL RECEPTACLE OUTLETS & UNDERCARPET RECEPTACLE OUTLETS. INSTALL CONDUITS FOR THE LOW VOLTAGE WIRING. THE ELECTRIC PANELS ARE EXISTING. ALL WORK IN ACCORDANCE WITH THE 2017 NEC.
* THE PERMIT IS AMENDED TO INCLUDE ADDITIONAL FIRE ALARM DEVICES & NAC PANEL FOR THE 4TH FLOOR FIT-OUT. THE DEVICES ARE CONNECTED TO THE EXISTING FIRE ALARM SYSTEM.City of Philadelphia · 2024
*** NO FIRE ALARM WORK ON THIS PERMIT****
1. Provide & install electrical work as per Scope Summary issued 10/2/24 by hpe group,
2. Furnish & install new lighting fixtures as per plans.
3. Furnish & install new lighting branch circuits for new lights
4. Furnish & install all duplex, & GFCI 20-amp receptacles as per plans.
5. Furnish & install new 20-amp 120-volt circuits for new receptacles as per plans.
6. Furnish & install new Combo exit/EM signs as per plans.
7. Furnish & install new 20-amp, single pole switches for lighting as per plans.
8. Reuse existing electrical panels.
9. Provide temporary lights & power.
10. Provide cost for inspection & permit feesCity of Philadelphia · 2024
INSTALL A PRE ACTION FIRE ALARM SYSTEM. ALL WORK IN ACCORDANCE WITH THE 2017 NEC.City of Philadelphia · 2024
Provide labor & material to install Clean Agent system as per
drawings dated 10/9/23 and 2016 NFPA 72.
1- SHP Panel, 2- Smoke Detectors, 1- Bell, 1 - Pre Action-Valve
InstallationCity of Philadelphia · 2024
Furnish & install complete network, data and security system. Installation of cameras, data jacks, IT room racks and patch panels.-2017 NEC.
**SEPARATE INTERIOR WIRING PERMITS REQ'D**City of Philadelphia · 2024