Is CULBERTSON RESTORATION LTD a real contractor?
CULBERTSON RESTORATION LTD appears in public building-permit records with 10 permits filed through 2026 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is CULBERTSON RESTORATION LTD's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to CULBERTSON RESTORATION LTD by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is CULBERTSON RESTORATION LTD licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. CULBERTSON RESTORATION LTD has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is CULBERTSON RESTORATION LTD's work?
The most recent permit on record for CULBERTSON RESTORATION LTD is dated 2026-04-29, with 10 permits on file in total.
MAKE SAFE PERMIT TO COMPLY WITH UNSAFE VIOLATION CF-2022-018527 TO INCLUDE LEGALIZATION OF REPAIRS TO EXTERIOR MASONRY WALLS PER APPROVED PLANS AND IN ACCORDANCE WITH CODE BULLETIN PM-1801. LICENSED PA PROFESSIONAL ENGINEER IS REQUIRED TO MONITOR REPAIRS MADE UNDER THIS PERMIT. THE ENGINEER MUST SUBMIT A SEALED STATEMENT TO THE DEPARTMENT CONFIRMING THAT THE STRUCTURE IS IN SOUND CONDITION AT COMPLETION. **FOR CONSTRUCTION PLANS/DOCUMENTS, REFERENCE PERMIT CP-2026-001680**City of Philadelphia · 2026
MAKE SAFE PERMIT TO COMPLY WITH UNSAFE VIOLATION CF-2022-018524 TO INCLUDE LEGALIZATION OF REPAIRS TO EXTERIOR MASONRY WALLS PER APPROVED PLANS AND IN ACCORDANCE WITH CODE BULLETIN PM-1801. LICENSED PA PROFESSIONAL ENGINEER IS REQUIRED TO MONITOR REPAIRS MADE UNDER THIS PERMIT. THE ENGINEER MUST SUBMIT A SEALED STATEMENT TO THE DEPARTMENT CONFIRMING THAT THE STRUCTURE IS IN SOUND CONDITION AT COMPLETION.City of Philadelphia · 2026
MAKE SAFE PERMIT TO COMPLY WITH UNSAFE VIOLATION CF-2022-018537 TO INCLUDE LEGALIZATION OF REPAIRS TO EXTERIOR MASONRY WALLS PER APPROVED PLANS AND IN ACCORDANCE WITH CODE BULLETIN PM-1801. LICENSED PA PROFESSIONAL ENGINEER IS REQUIRED TO MONITOR REPAIRS MADE UNDER THIS PERMIT. THE ENGINEER MUST SUBMIT A SEALED STATEMENT TO THE DEPARTMENT CONFIRMING THAT THE STRUCTURE IS IN SOUND CONDITION AT COMPLETION. **FOR CONSTRUCTION PLANS/DOCUMENTS, REFERENCE PERMIT CP-2026-001680**City of Philadelphia · 2026
FOR REPAIRS TO EXTERIOR WALL PER APPROVED PLANS.City of Philadelphia · 2024
FOR THE EXTERIOR ALTERATION TO REPAIR THE FACADE OF AN EXISTING STRUCTURE. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.City of Philadelphia · 2023
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you CULBERTSON RESTORATION LTD?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to CULBERTSON RESTORATION LTD's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
FOR THE STRUCTURAL REPAIR TO EXTERIOR WALL TO RESOLVE CASE #CF-2023-023882. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CASE #CF-2023-023882.
SUBJECT TO THE FOLLOWING CONDITIONS OF THE PHILADELPHIA HISTORICAL COMMISSION:
Approved scope, referencing O'DONNELL & NACCARATO drawings dated 6/30/2023:
• Install helical spiral pins at 24” o/c each way at the granite units (See Repair Sketch RS-1).
• Helical pins should extend into the backup structure / concrete beam. Patch penetrations with repair mortar to match the properties of the existing granite.
• Rout cracks in granite units and inject with a cementitious grout (See Repair Sketch RS-2).
• Patch along the routed crack path with a cementitious repair mortar that matches the properties of the existing granite.
• Repair stone spalls using either the salvaged pieces of granite, or a cementitious repair mortar
or dutchman that match the properties of the existing granite (See Repair Sketch RS-3). Install
helical spiral pins at these repair locations.
• Cut out and repoint cracked and deteriorated mortar joints using mortar that matches the
properties of the existing, adjacent mortar (See Repair Sketch RS-4).
• Cut out the bed joint between the base and center of the bay and install mortar that matches
the properties of the existing, adjacent mortar (See Repair Sketch RS-4).City of Philadelphia · 2023
MAKE SAFE PERMIT TO RESOLVE CASE VIOLATION # CF-2022-008355 FOR REPAIRING AND REBUILDING THE DAMAGED PARAPET WALL. AS PER APPROVED ENGINEERED PLANS AND ENGINEER REPORT. IF FIELD CONDITIONS VARY CONTACT THE DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS WILL BE REQUIRED FOR ANY ADDITIONAL ALTERATIONS NOT ADDRESSED IN THE ENGINEER'S REPORT / PLANS. Abutting sidewalk must be closed with fencing a minimum of 6 ft. in height. Separate Streets Department permit required for sidewalk closure. In accordance with Code Bulletin PM-1801, a PA professional engineer is required to monitor repairs made under this permit. The engineer must submit a sealed statement to the Department confirming that the structure is in sound condition at completion.
**PHC: All repairs to match existing in material, color, dimension, and details. Staff to approve new mortar and repointing mortar. Staff to approve sample of all proposed replacement materials for brick, terra cotta, stucco, and coping. Submittals can be sent to preservation@phila.gov.City of Philadelphia · 2022
REPOINTING WEST ELEVATION. BRICK ONLY ***SEE LOG NOTE*** REPAIRS AS APPROVED BY HISTORIC COMMISSIONCity of Philadelphia · 2017
FOR THE REMOVAL AND REPAIR OF MASONRY CORNICE WORK WITH THE REPAIR OF SUPPORTING STEEL, ALL WORK TO BE DONE PER APPROVED PLANS SEALED BY STRUCTURAL ENGINEER. STRUCTURAL ENGINEER TO BE ON SITE DURING STEEL INSPECTION. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.City of Philadelphia · 2017
INSTALL ONE BALCONY ON 14TH FL. SIZE AS APPROVED ZONING PLAN.City of Philadelphia · 2009