REMOVE AND ELECTRICAL REWIRE/DEVICES KITCHEN AS PER 2014 NECCity of Philadelphia · 2019
CONNECT ELECTRICAL APPLIANCES: FREEZER, KITCHEN DISHWASHER, SALAD AND PASTA PREP TABLES, ICE MACHINE, BAR DISHWASHER, BACK BAR REFRIGERATOR AND RECEPTACLES, SOUP WARMER, FOOD PROCESSOR AND POS, KITCHEN HOOD AND LIGHTING AS PER 2008 NEC. (NORTH DIST)***NO FIRE ALARM***City of Philadelphia · 2019
INSTALL NEW 400AMP SERVICE AND REWIRE ENTIRE SFD WITH RECEPTS,SWITCHES,LIGHTS,FIXTURES,CO DETECTORS AND LOW VOLTAGE AS PER 2008 NEC (NORTH DISTRICT)City of Philadelphia · 2018
RELOCATE EXISTING MASTER BEDROOM RECEPTS,SWITCHES ON WALLS BEING RELOCATED 1FT, ADD 4 LIGHTS TO EXISTING LIGHTING IN CLOSETS, 1" HIS MASTER CLOSET & 3" IN HER MASTER CLOSET AS PER 2008 NEC (CC DISTRICT)City of Philadelphia · 2018
RELOCATE ALL EXISTING KITCHEN CIRCUITS TO NEW KITCHEN LAYOUT, REWORK EXISTING LIGHTING, SWITCHES & RECEPTS TO NEW WALL LOCATIONS THAT WERE MOVED, ADD WIRIG FOR NEW LIGHTING FROM EXISTING LIGHTING SWTICHES & CIRCUITS AS PER 2008 NEC (CC DISTRICT)City of Philadelphia · 2018
SUPPLY AND INSTALL 100AMP SERVICE COMPLETE WITH METER, PANEL *+& GROUNDING, 35 TOTAL RECEPTS, 18 LIGHTS, 12 SWITCHES, 4 SMOKE DETECTORS, 1 CO DETECTOR AS PER 2008 NEC (EAST DISTRICT)City of Philadelphia · 2018
RE WORD EXISTING ELECTRIC, NEW FRAMING TO EXISTING ROOF JOISTS, INSTALL 2 NEW SWITCHES, AND LIGHT FOR PILOT HOUSE, 2 CIRCUITS FOR LIGHTS & OUTLET ON ROOF TOP AREA, ADD HARDWIRED SMOKES FROM 3RD FL 2 GFCI OUTLETS IN EXTERIOR COUNTER AREA AS PER 2008 NEC (SOUTH DISTRICT)
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2017
SUPPLY AND INSTALL 48-4" LV RECESSED LIGHTS RECONNECT EXISTING ELECTRIC TO APPLIANCES IN KITCHEN REMOVE AND REPLACE 8 SURFACE MOUNT LIGHT FIXTURES AT EXISTING LOCATIONS REPLACE EXISTING SWITCHES WITH DIMMERS IN 10 LOCATIONS REMOVE EXISTING UNDER CABINET LIGHTING AND INSTALL NEW LED LIGHTING ADD OUTLETS TO EXISTING CIRCUITS IN 6 LOCATIONS INSTALL LOW VOLTAGE WIRING FOR WINDOW SHADE MOTOR IN 8 LOCATIONS TO 120V CONTROL PANEL AS PER 2008 NEC (CC DISTRICT)City of Philadelphia · 2017
REPLACE OUTSIDE 100AMP SEU CABLE AND METER SOCKET, SEU CABLE TO EXISTING ELECTRICAL PANEL, INSTALL GROUND WIRE #6 TO COLD WATER PIPE AND WATER METER, REPLACE 4 WIRES THAT WERE DAMAGE BY REAR DOOR AS PER 2008 NEC (EAST DISTRICT)City of Philadelphia · 2017
INSTALL OWNER SUPPLIED STRING LIGHTING THROUGHOUT NEW PATIO SPACE. SUPPLY AND INSTALL 2 NEW CIRCUITS 120V 20A TO FEED LIGHTING OF 4 SWITCHES ALSO INSTALL 10 OWNER SUPPLIED HANGING LIGHTS AS PER NEC 2008City of Philadelphia · 2017
REPLACE EXISTING LIGHT FIXTURES IN BEDROOM HALLWAY(4),REMOVE AND REPLACE 2 BATHROOM WALL SOUNCES LIGHTS,GUEST BEDROOM,1 HALLWAY LIGHT AND ADD NEW WIRING FOR TRACK LIGHT(8FT),HALLWAY AND GUEST CLOSET ADD OCCUP.SWITCH AND LED LIGHT AND NEW WIRING FOR 2-WALL SCONCES IN LIVING ROOM AS PER 2008 NEC(CC DISTRICT)ALL WORK IS DONE BY PHISHING ONLYCity of Philadelphia · 2017
SUPPLY AND INSTALL WIRING FOR 1 EXHAUST FAN MOTOR AND 1 MAKE UP AIR MOTOR FOR EXHAUST HOOD, 2-120V 20AMP LINES, WIRE AND INSTALL ANSUL CONTROL BOX AND 2 LIGHTS UNDER HOOD EXHAUST AS PER 2008 NEC (NORTH DISTRICT)City of Philadelphia · 2017