What the public permit record shows, not self-reported reviews.
Is COMPREHENSIVE FIRE TECHNOLOGIE a real contractor?
COMPREHENSIVE FIRE TECHNOLOGIE appears in public building-permit records with 16 permits filed through 2022 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is COMPREHENSIVE FIRE TECHNOLOGIE's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to COMPREHENSIVE FIRE TECHNOLOGIE by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is COMPREHENSIVE FIRE TECHNOLOGIE licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. COMPREHENSIVE FIRE TECHNOLOGIE has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is COMPREHENSIVE FIRE TECHNOLOGIE's work?
The most recent permit on record for COMPREHENSIVE FIRE TECHNOLOGIE is dated 2022-05-12, with 16 permits on file in total.
FOR THE REPLACEMENT OF AN EXISTING FM200 CLEAN AGENT FIRE SUPPRESSION SYSTEM AS PER PLANS.City of Philadelphia · 2022
FOR THE REPLACEMENT OF AN EXISTING FM200 CLEAN AGENT FIRE SUPPRESSION SYSTEM AS PER PLANS.City of Philadelphia · 2022
Provide a Novec 1230 clean agent fire suppression and controls for a pre-action system to protect vault 1750, per approved plans. Any other work requires separate permits.City of Philadelphia · 2022
FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM FOR AN OIL PUMP PLANT, FIRE SUPPRESSION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND STANDARDS REFERENCED IN THE 2015 NFPA 750. ALL WORK TO BE DONE PER APPROVED PLANS AND DOCUMENTATION. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK (MECHANICAL/ELECTRICAL).City of Philadelphia · 2022
FOR A REPLACEMENT OF A CLEAN AGENT SYSTEM IN ACCORDANCE WITH NFPA 2001, IN ROOM 626 WITHIN AN EXISTING STRUCTURE, AS PER APPROVED PLANS.City of Philadelphia · 2021
For the installation of an FM200 clean agent system within a server room on the 10th floor of an existing high-rise office building, as per plans; no other work on this permit; connecting to existing piping; see CP-2021-002968 for associated building permit.City of Philadelphia · 2021
FOR THE INSTALLATION OF TWO (2) FM-200 CLEAN AGENT SUPPRESSION SYSTEMS FOR SERVER ROOMS 1 & 2, IN ACCORDANCE WITH NFPA 2001, AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK.
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you COMPREHENSIVE FIRE TECHNOLOGIE?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to COMPREHENSIVE FIRE TECHNOLOGIE's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2019
INSTALLATION OF FM-200 CLEAN AGENT FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 2001.City of Philadelphia · 2017
INSTALLATION OF ONE FM-200 SYSTEM AND PRE-ACTION DETECTION AND CONTROL SYSTEMS IN MAIN IDF AND CARRIER ROOMS P1115 AND P1116. SYSTEM INLCUDES NECESSARY CONTROL PANEL MANUAL RELEASE, ABORT, AUDIBLES, FM-200 TANKS NOZZELS AND MONITORING OF PRE-ACTION SYSTEM. ELECTRICAL PERMIT REQ'DCity of Philadelphia · 2015
INSTALLATION OF ONE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH TWO (2) TANKS WITH A TOTAL OF EIGHT (8) NOZZLES TO INCLUDE SMOKE DETECTORS, MANUAL STATION, ABORT STATION, CONTROL PANEL, AUDIBLE DEVICES, STORAGE CYLINDER AND NOZZLES FOR THE SERVER ROOM. SPRINKLER SYSTEM TO BE PERFORMED BY OTHER. INSTALLATION OF A FIRESUPRESSION SYSTEM IN ACCORDANCE WITH NFPA 2001. SEPARATE ELECTRICAL PERMIT IS REQUIRED.City of Philadelphia · 2013
INSTALLATION OF ONE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH (2) NOZZLES TO INCLUDE SMOKE DETECTORS, MANUAL STATION, ABORT STATION, CONTROL PANEL, AUDIBLE DEVICES, STORAGE CYLINDER AND NOZZLES FOR THE SERVER ROOM. SPRINKLER SYSTEM TO BE PERFORMED BY OTHER. INSTALLATION OF A FIRESUPRESSION SYSTEM IN ACCORDANCE WITH NFPA 2001. SEPARATE ELECTRICAL PERMIT IS REQUIRED.City of Philadelphia · 2013
FOR THE INSTALLATION OF THREE (3) AUTOMATIC CLEAN AGENT FIRE SUPPRESSION SYSTEMS WITH FOUR (4) TOTAL NOZZLES FOR A DATA CENTER AND TWO EQUIPMENT ROOMS IN AN EXISTING BUILDING AS PER APPROVED PLANS; INSTALLATION OF FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 2001.City of Philadelphia · 2013
Permitted projects on public record. Addresses are omitted for privacy.