What the public permit record shows, not self-reported reviews.
Is CHATHAM BAY CONSTRUCTION SERVICES LLC a real contractor?
CHATHAM BAY CONSTRUCTION SERVICES LLC appears in public building-permit records with 4 permits filed through 2024 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is CHATHAM BAY CONSTRUCTION SERVICES LLC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to CHATHAM BAY CONSTRUCTION SERVICES LLC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is CHATHAM BAY CONSTRUCTION SERVICES LLC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. CHATHAM BAY CONSTRUCTION SERVICES LLC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is CHATHAM BAY CONSTRUCTION SERVICES LLC's work?
The most recent permit on record for CHATHAM BAY CONSTRUCTION SERVICES LLC is dated 2024-08-29, with 4 permits on file in total.
NEW CONSTRUCTION OF A SIX (6) STORY HORIZONTAL ADDITION WITH ROOF DECK FOR USE AS SHELL INDUSTRIAL SPACE (FIT-OUT PERMIT REQUIRED PRIOR TO OCCUPANCY) AND ONE HUNDRED (100) DWELLING UNITS WITH ACCESSORY PARKING AS PER APPROVED PLANS. BUILDING TO UTILIZE HORIZONTAL SEPARATIONS TO CREATE TWO (2) SEPARATE BUILDINGS WITH TWO (2) DIFFERENT CONSTRUCTION TYPES (1ST FLOOR - TYPE IA AND 2ND THROUGH 6TH FLOORS - TYPE IIIB). FIRE RETARDANT TREATED STUDS AND SHEATHING REQUIRED FOR TYPE III CONSTRUCTION. BUILDING TO BE FULLY SPRINKLERED PER NFPA 13 AND INCLUDE STANDPIPES PER NFPA 14. FIRE WATCH REQUIRED PER CODE BULLETIN F-2001. *2018 IBC* **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**
AMENDMENT APPROVED 4/10/25
AMEND ALTERATIONS/ADDITION PERMIT CP-2024-000182 FOR CHANGE TO SPECIAL INSPECTIONS AGENCY AS PER APPROVED DOCUMENTATION.City of Philadelphia · 2024
FOR THE CONSTRUCTION OF ONE-STORY ADDITION (4TH FLOOR) ABOVE THE EXISTING THIRD FLOOR AND ADDITION OF REAR NEW FIRE ESCAPE STAIR AND PROVIDING GREEN ROOF TO INCLUDE STRUCTURAL FRAMING THROUGHOUT AN EXISTING ATTACHED STRUCTURE. FOR USE AS A MULTI-FAMILY HOUSEHOLD LIVING. AS PER APPROVED PLANS.City of Philadelphia · 2023
LEVEL III ALTERATIONS WITH COMPLETE CHANGE OF OCCUPANCY TO CREATE SEVENTY-SEVEN (77) DWELLING UNITS IN AN EXISTING FIVE (5) STORY BUILDING AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED PER NFPA 13 AND INCLUDE STANDPIPES PER NFPA 14. *2018 IEBC REVIEW*
**SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**
AMENDMENT APPROVED 6/1/23
AMEND ALTERATIONS PERMIT CP-2022-002890 FOR CHANGES TO WALL TYPES AND BUILDING LAYOUT AS PER APPROVED PLANS.
AMENDMENT APPROVED 9/8/23
AMEND ALTERATIONS PERMIT CP-2022-002890 TO INCLUDE ELEVATOR PIT UNDERPINNING DETAILS AS PER APPROVED PLANS.
AMENDMENT APPROVED 3/12/24
AMEND ALTERATIONS PERMIT CP-2022-002890 TO UPDATE PLAN NOTES RELATED TO WALL OPENINGS AS PER APPROVED PLANS.
AMENDMENT APPROVED 4/12/25
AMEND ALTERATIONS PERMIT CP-2022-002890 TO CHANGE DPRC-SI AND SPECIAL INSPECTIONS AGENCY AS PER APPROVED DOCUMENTATION.City of Philadelphia · 2022
AMENDMENT: FOR THE AMENDMENT OF PREVIOUSLY APPROVED PERMIT TO DOCUMENT CHANGE IN SPECIAL INSPECTION AGENCY AS SHOWN PER APPROVED DOCUMENTATION. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
ORIGINAL: FOR THE ERECTION OF A FIVE STORY BUILDING FOR THE USE OF STORAGE IN THE BASEMENT LEVEL, ACCESSORY PARKING AND VACANT COMMERCIAL SPACE ON THE FIRST FLOOR LEVEL (SEPARATE USE PERMIT REQUIRED AND INTERIOR FIT-OUT REQUIRED PRIOR TO OCCUPANCY) WITH RESIDENTIAL UNITS (THIRTY SIX DWELLING UNITS) FROM THE SECOND THROUGH FIFTH FLOOR LEVEL. ALL UNITS ARE TYPE B DWELLING UNITS WITH THE EXCEPTION OF ONE TYPE A UNIT. ROOF DECKS TO BE LOCATED ON THE FIFTH FLOOR LEVEL. BUILDING TO BE FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND STANDPIPES TO BE LOCATED IN EXIT STAIRWAYS IN ACCORDANCE WITH NFPA 14. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. FOUNDATION WAS APPROVED UNDER CP-2020-001125. **A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 19 FEET OF THE BUILDING FACADE IN ACCORDANCE WITH SECTION 3306 OF THE 2018 IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMIT REQUIRED PRIOR TO THE START OF ANY WORK.***AMENDED PERMIT TO BE OBTAINED FOR UNDER PINNING WORK.*** FIRE WATCH IS REQUIRED ONCE COMBUSTIBLE CONSTRUCTION IS OVER 40 FEET IN HEIGHT, A SITE SAFETY PLAN SHALL BE SUBMITED TO BUILDING INSPECTOR PRIOR TO THE START OF ANY CONSTRUCTION.*** SEPARATE PERMIITS TO BE OBTAINED FOR ALL OTHER WORK.