What the public permit record shows, not self-reported reviews.
Is CAL Development Group LP a real contractor?
CAL Development Group LP appears in public building-permit records with 11 permits filed through 2026 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is CAL Development Group LP's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to CAL Development Group LP by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is CAL Development Group LP licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. CAL Development Group LP has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is CAL Development Group LP's work?
The most recent permit on record for CAL Development Group LP is dated 2026-04-02, with 11 permits on file in total.
FOR LEVEL III INTERIOR ALTERATIONS AND THE ERECTION OF ADDITIONS WITH A COMPLETE CHANGE IN USE AND OCCUPANCY CLASSIFICATION TO GROUP R-2 MULTI-FAMILY (FORTY-FOUR (44) DWELLING UNITS). BUILDING TO BE FULLY SPRINKLERED PER NFPA 13. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IBC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, FIRE SUPPRESSION, AND EXCAVATION WORK.City of Philadelphia · 2026
MAKE SAFE PERMIT TO COMPLY WITH CF-2023-076114 TO INCLUDE INSTALLATION OF STAR BOLTS, REPAIRS/REPLACEMENT OF EXTERIOR WALL ABOVE GARAGE, FRONT DOOR AND FRAMING PER APPROVED PLANS AND IN ACCORDANCE WITH CODE BULLETIN PM-1801. LICENSED PA PROFESSIONAL ENGINEER IS REQUIRED TO MONITOR REPAIRS MADE UNDER THIS PERMIT. THE ENGINEER MUST SUBMIT A SEALED STATEMENT TO THE DEPARTMENT CONFIRMING THAT THE STRUCTURE IS IN SOUND CONDITION AT COMPLETION. SEPARATE PERMITS REQUIRED FOR ADDITIONAL ALTERATIONS NOT ADDRESSED IN APPROVED PLANS.
AMENDMENT APPROVED ON 8/14/2025 FOR THE INSTALLATION OF STAR BOLTS AND INTERIOR ALTERATIONS FOR BLOCKING AND
PLATE INSTALLATION. ****************************************City of Philadelphia · 2025
FOR LEVEL II INTERIOR ALTERATIONS AT THE BASEMENT AND 1ST FLOOR WITH A PARTIAL CHANGE IN USE & OCCUPANCY CLASSIFICATION TO GROUP A-2 ASSEMBLY & ENTERTAINMENT. EXISTING BUILDING IS FULLY SPRINKLERED PER NFPA 13. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. SEE ZP-2024-007601 FOR ZONING APPROVAL OF USE.City of Philadelphia · 2025
FOR LEVEL II INTERIOR ALTERATIONS WITH A COMPLETE CHANGE IN USE & OCCUPANCY CLASSIFICATION TO GROUP R-2 THREE (3) DWELLING UNITS. BUILDING TO BE FULLY SPRINKLERED WITH A MINIMUM OF A NFPA 13R AUTOMATIC SPRINKLER SYSTEM. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK. SEE ZP-2021-006002 FOR ZONING APPROVAL.
[AMENDMENT 3/25/2024 FOR CHANGES TO 1ST FLOOR FRAMING, WINDOW & DOOR HEADERS, INSTALLATION OF STAR BOLTS, AND 1ST FLOOR WINDOW & DOOR ELEVATIONS AS PER APPROVED AMENDED PLANS.]
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you CAL Development Group LP?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to CAL Development Group LP's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2023
FOR THE CONSTRUCTION / ALTERATIONS THROUGHOUT AN EXISTING ATTACHED STRUCTURE TO INCLUDE REPLACEMENT OF STAIRCASES.
FOR A TWO-FAMILY HOUSEHOLD LIVING. AS PER PLANS.
AMENDMENT:The only reason for the amendment is to correct an error on the original Permit Application. The Total Cost of Construction Work should be $140,000.00 and not $40,000.00. There are no changes to the approved plans or in the scope of work for this permit.City of Philadelphia · 2021
FOR CONSTRUCTION OF (1) NEW FOUR STORY STRUCTURE OF TYPE VA CONSTRUCTION WITH A CELLAR AND A ROOF DECK WITH ROOF ACCESS STRUCTURES, 6-FAMILY DWELLING PLUS VACANT COMMERCIAL AT ENTIRE FIRST FLOOR AND CELLAR WITH COMMON ROOF DECK ACCESSED BY (2) EXTERIOR STAIRS AS PER PLANS.
AMENDMENT (11/29/2021) FOR THE REMOVAL OF THE 30 MINIUTES RATED COMMON HALL ON THE SECOND AND THIRD FLOOR AS PER PLANS.City of Philadelphia · 2021
FOR THE ERECTION OF ONE (1) ATTACHED STRUCTURE WITH CELLAR AND AN ACCESSORY WALK-OUT ROOF DECK ABOVE 4TH FLOOR AND ROOF DECK WITH ROOF ACCESS STRUCTURES (FOR RESIDENTIAL USE ONLY), AND BALCONY ON FRONT AND REAR 2ND TO 4TH FLOOR.FOR MULTI-FAMILY HOUSEHOLD LIVING TWENTY-FOUR (24) DWELLING UNITS AND FOUR (4) ACCESSORY OFF-STREET INTERIOR PARKING SPACES INCLUDING 1 ADA / VAN ACCESSIBLE SPACE AND TWELVE (12) CLASS 1A BICYCLE PARKING SPACES ON AN ACCESSIBLE ROUTE. BUILDING TO BE FULLY SPRINKLERED. SEPARATE APPROVAL REQUIRED FOR MEPS WORK.
AMENDMENT TO CREATE A HORIZONTAL EXIT ON 5TH FLOOR ONLY AS PER APPROVED REIVSED PLANS.
AMENDMENT TO THE BUILDING AREA DUE TO ONSITE EXISTING CONDITION AND CHANGE TO THE FIRE RATED ASSEMBLIES AS PER APPROVED REVISED PLANS.
Amendment to change Design Professional in Responsible Charge of Special Inspections (DPRC-SI) from Geostructures, Inc. (Jack Parisi) to AR Engineers. for the following Special Inspections:
1705.2.1 Structural Steel
1705.2.2 Cold-formed steel deckCity of Philadelphia · 2021
FOR THE ERECTION OF (1) NEW 3 STORY ATTACHED STRUCTURE OF TYPE VB CONSTRUCTION FOR FOUR FAMILY DWELLING WITH A CELLAR AND A PILOT HOUSE FOR ROOF DECK AS PER PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.City of Philadelphia · 2019
LEVEL II ALTERATIONS WITH PARTIAL CHANGE OF OCCUPANCY TO CREATE A DAY CARE CENTER ON THE FIRST FLOOR AND BASEMENT OF AN EXISTING BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. SEE BBS VARIANCE NO. 31018 FOR APPROVAL OF PARTY WALL BREACHES. *2018*
**SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**City of Philadelphia · 2019
LEVEL II ALTERATIONS WITH PARTIAL CHANGE OF OCCUPANCY TO CREATE A DAY CARE CENTER ON THE FIRST FLOOR AND BASEMENT OF AN EXISTING BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. SEE BBS VARIANCE NO. 31018 FOR APPROVAL OF PARTY WALL BREACHES. **SEE A/P 980075 FOR PLANS** *2018*
**SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**City of Philadelphia · 2019
EZ PERMIT STANDARDS ALTERATIONS- For alterations to an Existing One Family Dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans.( AS PER HISTORIC COMMISSION APPROVAL)City of Philadelphia · 2019
Permitted projects on public record. Addresses are omitted for privacy.