What the public permit record shows, not self-reported reviews.
Is BORKSON PROPERTIES a real contractor?
BORKSON PROPERTIES appears in public building-permit records with 48 permits filed through 2016 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is BORKSON PROPERTIES's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to BORKSON PROPERTIES by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is BORKSON PROPERTIES licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. BORKSON PROPERTIES has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is BORKSON PROPERTIES's work?
The most recent permit on record for BORKSON PROPERTIES is dated 2016-11-04, with 48 permits on file in total.
NEW CONSTRUCTION OF 3 STORY STRUCTURE, PILOT HOUSE, ROOF DECK APPENDAGES. BUILDING SPRINKLERED. NO UNDERPINNING OR SPECIAL PRECAUTIONS CITED BY ENGINEER, TO BE ON SITE FOR EXCAVATION.FULLY SPRINKLERD BUILDING IN ACCORDANCE WITH NFPA 13 AS PER BBS VARAINCE.
ADD'L PERMITS REQ: ELECTRICAL, PLUMBING, HVAC, SPRINKLERS.City of Philadelphia · 2016
FOR THE ERECTION OF A FOUR STORY STRUCTURE CONTAINING COMMERCIAL AND TWO DWELLING UNITS, TWO ROOF DECKS, ACCESSED BY PILOT HOUSES (CONTAINING STAIRS AND LANDING ONLY) AS PER PLANS.City of Philadelphia · 2016
EZ PERMIT STADARD ALTERATIONS- FOR ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.City of Philadelphia · 2016
FOR THE NEW CONSTRUCTION OF A NEW THREE STORY ATTACHED STRUCTURE WITH SEVEN DWELLING UNITS AS PER PLANS. NO ROOF DECK OR ROOF ACCESS STRUCTURE. SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK.City of Philadelphia · 2016
FOR THE ERECTION OF AN ATTACHED STRUCTURE WITH ROOF DECK WITH ROOF DECK ACCESS STRUCTURE ABOVE THE 3RD FLOOR LEVEL AND DECK AT REAR 2ND FLOOR LEVEL. SIZE AND LOCATION AS SHOWN ON APPLICATION/PLAN.
FOR USE AS A SINGLE FAMILY DWELLING WITH ONE (1) INTERIOR ACCESSORY PARKING SPACE.City of Philadelphia · 2016
INSTALLATION OF NEW REINFORCED CONCERETE FOOTINGS AND CMU FOUNDATION FOR NEW THREE (3) STORY WOOD-FRAME REAR ADDITION WITH ROOF DECK ABOVE AND LEDGER ATTACHMENT AT WESTERLY WALL ONLY PER ENGINEER'S DETAIL. NEW BRACED WALL PANELS (BWP) AND LIMITED MODIFICATION OF EXISTING FLOOR FRAMING AT STAIRWAYS / BWP'S, NON-BEARING PARTITIONS AND FINSHES THROUGHOUT PER PLANS. ALL SPECIAL INSPECTION REPORTS TO BE FURNISHED TO FIELD INSPECTOR (NO UNDERPINNING). SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS. PROTECTION OF ADJACENT PROPERTIES / PEDESTRIANS REQUIRED DURING ALL CONSTRUCTION.
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you BORKSON PROPERTIES?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to BORKSON PROPERTIES's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2016
NEW FRONT AND BACK DOOR, NEW WINDOWS , NEW HARDWOOD FLOORS, NEW TILE IN BATHROOM, NEW PAINT , FRAME, NEW CLOSETS, NEW RIM AND MOULDING THROUGHOUT HOUSE, NEW STUCCO IN FRONT OF HOUSE, DEMO OF OLD KITCHEN, NEW INTERIOR DOORS EZ PERMIT STANDARD ALTERATIONS- FOR ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.City of Philadelphia · 2015
TO AMEND FOUNDATION PERMIT AP#589000, FOR REVISIONS OF UNDERPINNING DETAILS AND INSTALLATION OF RETAINING WALL STRUCTURES, DUE TO ON SITE MODIFICATIONS VERIFIED IN FIELD BY ENGINEER ON RECORD AS PER PLANS SUBMITTED BY LICENSED PROFESSIONAL ENGINEER. LICENSED PROFESSIONAL ENGINEER ON RECORD TO BE ON-SITE TO CONDUCT CONTINUOUS SPECIAL INSPECTIONS PER CODE BULLETIN B-0503. **PER CODE BULLETIN B-0702, WRITTEN NOTICE SHALL BE PROVIDED TO THE OWNERS OF THE ADJOINING PROPERTY ADVISING THEM THAT THE EXCAVATION IS TO BE MADE AND THAT ADJOINING BUILDINGS SHOULD BE PROTECTED, TO BE DELIVERED NOT LESS THAN TEN (10) DAYS PRIOR TO THE SCHEDULED START DATE OF THE EXCAVATION.**City of Philadelphia · 2015
FOR THE NEW CONSTRUCTION OF A FOUR STORY BUILDING TO BE USED AS VACANT COMMERCIAL ON FIRST FLOOR FRONT (SEPARATE CERTIFICATE OF OCCUPANCY REQUIRED PRIOR TO OCCUPANCY) AND FOUR DWELLING UNITS FROM 2ND THROUGH 4TH FLOORS WITH AN ACCESSORY ROOF DECK AS PER APPROVED PLANS.City of Philadelphia · 2015
FOR THE ERECTION OF AN ADDITION AT THE 2ND FLOOR REAR OF AN EXISTING STRUCTURE AND FOR ROOF DECKS AT THE 2ND AND 3RD FLOOR REAR. STRUCTURE FOR CONTINUED USE AS SINGLE FAMILY HOUSEHOLD LIVING. SEPARATE PERMITS REQUIRED FOR PLUMBING, ELECTRICAL AND MECHANICAL.City of Philadelphia · 2015
TO AMEND FOUNDATION PERMIT AP#589000, FOR REVISIONS OF UNDERPINNING DETAILS DUE TO ON SITE MODIFICATIONS VERIFIED IN FIELD BY ENGINEER ON RECORD AS PER PLANS SUBMITTED BY LICENSED PROFESSIONAL ENGINEER. LICENSED PROFESSIONAL ENGINEER ON RECORD TO BE ON-SITE TO CONDUCT SPECIAL INSPECTIONS PER CODE BULLETIN B-0503. **PER CODE BULLETIN B-0702, WRITTEN NOTICE SHALL BE PROVIDED TO THE OWNERS OF THE ADJOINING PROPERTY ADVISING THEM THAT THE EXCAVATION IS TO BE MADE AND THAT ADJOINING BUILDINGS SHOULD BE PROTECTED, TO BE DELIVERED NOT LESS THAN TEN (10) DAYS PRIOR TO THE SCHEDULED START DATE OF THE EXCAVATION. APPROVAL OF CONSTRUCTION PLANS DOES NOT BESTOW ANY RIGHT TO ENTER UPON OR DISTURB THE ADJOINING PROPERTY WITHOUT THAT OWNER'S PERMISSION.**City of Philadelphia · 2015
FOR THE ERECTION OF A FOUR STORY STRUCTURE WITH A ROOF DECK ACCESSED BY A ROOF DECK ACCESS STRUCTURE. BUILDING FOR USE AS A FOUR FAMILY DWELLING. BUILDING TO BE FULLY SPRINKLERED.APPLICATION GRANTED BY BOARD OF BUILDING STANDARDS CASE NO.24956. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT STRUCTURAL ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL ,ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.PLEASE REFERENCE AP#592446 FOR APPROVED DOCUMENTATION AND PLANS FOR FOUNDATION WORK.PLEASE REFER TO AP#597552 FOR APPROVED BUILDING PLANS AND DOCUMENTATION.City of Philadelphia · 2015