STATEMENT OF WORK:
HORIZONTAL CABLING:
Cabling will be Superior/Essex Category 6A plenum rated 4-pair and CommScope RG6 quad shield plenum rated coax..
• Provide labor to demo/remove all Category 5/6/6A cables in scope area. Demo scope for this project includes removal of existing wall mount bracket and surface mount boxes for existing horizontal cabling in the existing IDF.
• Provide and install two (2) flush mount quad Category 6A locations.
• Provide and install nine (9) flush mount triple Category 6A locations.
• Provide and install twenty (20) flush mount dual Category 6A locations.
• Provide and install seven (7) surface mount single Category 6A wireless access point locations.
• Provide labor to install seven (7) customer-provided wireless access points.
• Provide and install seven (7) single Category 6A surface mount CCTV locations.
• Provide and install three (3) flush mount triple (2 Category 6A/1 coax) TV locations.
• Provide and install two (2) single Category 6A flush mount locations.
• Provide and install Ortronics faceplates, surface mount boxes, modular jacks, couplers and connectors as required for termination of the 4-pair and coax cables at the workstation location.
• Provide and install three (3) Ortronics 48-port modular patch panels, each loaded with the required modular jacks. These will be installed in the appropriate closet location for termination of the 4-pair cables installed.
COPPER BACKBONE CABLING: (AFTER HOURS)
• Provide labor to relocate existing 50-pair cable from existing Teledata IDF to the new IDF on the same floor.
• Re-use of any backbone cable assumes the lengths of these cables are adequate and in proper condition to be re-used in the new IDF.
FIBER BACKBONE CABLING: (AFTER HOURS)
• Provide labor to relocate existing 12-strand fiber optic cable from existing Teledata IDF to the new IDF on the same floor.
• Re-use of any backbone cable assumes the lengths of these cables are adequate and in proper conCity of Philadelphia · 2026
HORIZONTAL CABLING:
Cabling will be CommScope Category 6A plenum rated 4-pair and CommScope RG6 quad shield plenum rated coax.
• Provide and install two (2) surface mount single Category 6A access control panel locations.
• Provide and install twenty-two (22) surface mount single Category 6A camera locations.
• Provide and install one (1) surface mount single Category 6A emergency phone location.
• Provide and install one (1) surface mount single Category 6A Int DS location.
• Provide and install one (1) surface mount single Category 6A time clock location.
• Provide and install one (1) single Category 6A wall phone location.
• Provide and install one (1) flush mount dual (Category 6A/coax) TV location.
• Provide and install thirteen (13) flush mount dual Category 6A locations.
• Provide and install ten (10) furniture mount dual Category 6A locations.
• Provide and install eight (8) surface mount dual Category 6A wireless access point locations.
• Provide labor to install eight (8) customer-provided wireless access points.
• Provide and install three (3) flush mount quad Category 6A locations.
• Provide and install CommScope faceplates, surface mount boxes, modular jacks, couplers and connectors as required for termination of the 4-pair and coax cables installed at the workstation location.
• Provide and install four (4) CommScope Category 6A 48-port patch panels. This will be installed at the closet location for termination of the Category 6A 4-pair cables installed.
PATCH CORDS:
• Provide and install the following patch cords; plenum rated patch cords are furnish only.
DESCRIPTION
MFG
P/N
QTY
Category 6A Patch Cord - 7' (TR)
CommScope
UC1AAA2-xxF007
103
Category 6A Patch Cord - 10' (WS)
CommScope
UC1AAA2-xxF010
65
Category 6A Plenum Patch Cord - 10' (WAP's & Cameras)
CommScope
UC1AA22-xxF010
COPPER BACKBONE CABLING:
• Provide and install one (1) CommScope Category 3 plenum rated 25-pair cables from the Dock Level Telecom Room to the Concourse Level Cabinet and
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Philadelphia · 2026
DEMO:
• Provide labor to remove existing cabling from workstations and coil for re-use, or leave coiled on tray and labeled for future use on 5th Floor.
• Provide labor to remove existing cabling from workstations and coil for re-use, or leave coiled on tray and labeled for future on 6th Floor.
HORIZONTAL CABLING:
New cabling will be Superior/Essex Category 6A plenum rated 4-pair.
• Provide labor to reinstall one hundred forty-three (143) cables coiled in ceiling on the 5th Floor, provide labor to reinstall one hundred thirty-three (133) cables coiled in ceiling on the 6th Floor and provide and install one hundred one (101) new Category 6A cables into the following configurations:
¿ Two (2) flush mount single locations
¿ Nine (9) surface mount single room scheduler locations
¿ Twelve (12) surface mount single wireless access point locations
¿ Three (3) ceiling mount dual locations
¿ Fifty-six (56) flush mount dual locations.
¿ Ninety-eight (98) furniture mount dual locations
¿ Two (2) ceiling mount quad locations
¿ Four (4) floor mount quad locations
¿ Four (4) flush mount quad locations
• Provide labor to install twelve (12) customer-provided wireless access points.
• Provide and install Panduit faceplates, surface mount boxes and floor frames as required at each workstation location.
• Provide labor to reinstall existing modular jacks and install new modular jacks as required for termination of the 4-pair cables at the workstation location.
• Provide and install two (2) Panduit Category 6A 48-port patch panels. These will be installed at the appropriate closet location for termination of the new 4-pair cables installed. Existing hardware will be utilized for overage cables.
• Provide and install all necessary j-hooks and mounting accessories as required to facilitate cable distribution.
• Bluestone Communications, Inc. will provide labor to test and label all new cabling installed by Bluestone Communications, Inc. throughout the facility. Test resultsCity of Philadelphia · 2026
STATEMENT OF WORK:
HORIZONTAL CABLING:
• Based on cable take-off list provided by Preferred Comm Tech, Bluestone has included the installation of one hundred eighty-five (185) Category 6 network cables and twelve (12) Category 6A cables for wireless access points. Counts include additional cables for 7th Floor.
• Provide labor to install twelve (12) customer-provided wireless access points.
• Provide labor to install thirty-five (35) customer-provided room schedulers and patch cords.
• Provide labor to install faceplates, surface mount boxes and modular jacks as required for termination of the 4-pair cables installed.
• Provide labor to install six (6) 48-port patch panels. These will be installed at the appropriate closet location for termination of the 4-pair cables installed.
• Provide labor to install three hundred ninety-four (394) patch cords.
• Provide labor to relocate (41) existing single locations, reterminate and test it in the new faceplate and blank off the old location. This work will be performed after hours.
RACKS & LADDER RACKING:
• Provide labor to install two (2) racks, two (2) wire managers and ladder racking as required at the closet location.
• Provide labor to ground the racks and ladder racking.
• Provide labor to assist with the rack and stack of IT equipment.City of Philadelphia · 2026
Install telecommunication system infrastructure on the 3rd, 4th, 6th, and 7th floors. Work includes installation of low-voltage cabling, data/communication outlets, jacks, terminations, and associated pathway supports as required to serve each floor.
All work shall be installed in accordance with the 2017 NEC and per approved plans.
Amendment: Install six (6) additional CAT 6A data cables to serve the conference room and office. Work includes routing, supporting, terminating, and testing of all cabling, as well as installation of associated data jacks and connections.City of Philadelphia · 2026
HORIZONTAL CABLING:
Cabling will be BerkTek Category 6 plenum rated 4-pair and Belden RG6 quad shield plenum rated coax for TV applications.
• Provide and install three (3) flush mount single locations.
• Provide and install one (1) floor mount single location.
• Provide and install one (1) flush mount wall phone location.
• Provide and install twenty-four (24) flush mount dual location.
• Provide and install sixteen (16) furniture dual locations.
• Provide and install two (2) flush mount dual (1 data/ 1 coax) TV location.
• Provide and install faceplates, floor mount boxes, modular jacks, couplers and connectors as required for termination of the 4-pair and coax cables at the workstation location.
• Provide and install five (5) Tripp Lite Category 6 24-port patch panels. These will be installed in the appropriate IDF for termination of the 4-pair network cables installed.
• The coax cables will be terminated and left coiled at the closet location for final connections by others.
• Furnish eighty-nine (89) smart pack category 6 Neat patch cords, 2’ in length.
FIBER BACKBONE CABLING:
• Provide and install one 12-strand Corning single mode armored fiber from maintenance Building to logistics center.
• Provide and install twenty-four (24) Corning LC single mode fuse-on connectors. These will be installed for termination of each strand of single mode fiber optic cable installed.
• Provide and install two (2) 1RU fiber connector housing equipped with the required loaded panels. This will be installed in the appropriate IDF for housing fiber optic terminations.
• Provide labor to test and terminate.City of Philadelphia · 2026
STATEMENT OF WORK:
FIBER CABLING:
• Provide labor to install 288-strand singlemode non-armored ribbon fiber optic cable from the Head End to Comm Rooms 3.12.04, 3.37.03, 5.37.04, 5.08.03, 5.22.04 and North Tunnell IDF.
• Provide labor to install of 6-strand fiber/conductor composite cable from Comm Rooms 3.12.04, 3.37.03, 5.37.04, 5.08.03, 5.22.04 and North Tunnell IDF as required out to twenty-seven (27) remote locations.
• Provide labor to install the following equipment as required to facilitate fiber installation/termination:
DESCRIPTION QTY
4RU rack mount enclosure (HE) 6
4RU rack mount enclosure (IDF) 12
24f SM polimods (HE) 8
24f SM polimods (IDF's) 14
6f or 12f SM polimods (Nodes) 27
Fiber splice ribbon - (27) 6 strand ribbons (HE side of the 288 strand) 162
Fiber splice ribbon - (54) 6 strand ribbons (IDF side of the 288 strand) (IDF side of the 6 strand composite) 324
Fiber splice ribbon - (27) 6 strand ribbons (Node side of the 6 strand composite) 162
• Provide labor and material to label cables, panels and enclosures.
• Provide labor to test all fiber strands.
• Provide labor to install one (1) optical splicing and distribution outdoor fiber enclosures at each of twenty-seven (27) node ends.
PATHWAYS & FIRESTOP:
• Provide labor to install j-hooks and beam clamps or mounting accessories as required to facilitate cable distribution.
• Provide labor to seal all through penetrations of fire rated walls for telecommunications use to maintain necessary fire ratings.
HEAD END RELOCATION:
• Provide labor to relocate six (6) 288-strand fiber optic cables from temporary location to permanent location.
• Provide labor to install enclosures, polimods and splice ribbons as required to facilitate relocation.City of Philadelphia · 2026
HORIZONTAL CABLING:
Cabling will be CommScope Category 6 plenum rated 4-pair.
• Provide and install one (1) single wall phone location.
• Provide and install fifty-six (56) furniture mount single locations.
• Provide and install twenty-three (23) flush mount dual locations.
• Provide and install ten (10) flush mount single TV locations.
• Provide and install thirty-six (36) flush mount single locations.
• Provide and install twelve (12) flush mount quad locations.
• Provide and install ten (10) ceiling mount single wireless access point locations.
• Provide and install seven (7) flush mount single state locations.
• Provide and install CommScope faceplates, surface mount boxes and modular jacks as required for termination of the 4-pair cables at the workstation location.
• Provide and install six (6) CommScope 48-port flat modular patch panels, each loaded with the required modular jacks. These will be installed at the appropriate closet location for termination of the 4-pair cables.
FIBER BACKBONE CABLING:
• Provide and install one (1) Corning 12-strand 50um OM3 multimode plenum rated fiber optic cable from the MDF to the IDF.
• Provide and install twenty-four (24) Corning LC multimode connectors. These will be installed for termination of each strand of fiber optic cable installed.
• Provide and install two (2) Corning 1RU rack mount enclosures, each equipped with one (1) loaded panel. One (1) each will be installed in the MDF and IDF for housing fiber optic terminations.City of Philadelphia · 2026
• Current furniture layout has one hundred seventy-six (176) Category 6A shielded cables that are available to be relocated. Approximately one hundred eight (108) cables will be relocated to accommodate the new furniture layout.
• We will install one hundred and eight (108) new Category 6A shielded cables for furniture, column and floor mount locations. Eighty-four (84) of these Category 6A shielded cables will be installed to the 12th Floor West IDF. The twenty-four (24) floor mount cables will be installed from the West IDF. The new cables to Columns include four (4) new cables per each of four (4) columns for Displays and (1) cable for a time clock at each of the four columns.
• We will install twenty-six (26) new Category 6A Shielded cables to the Video Wall. These cables will be run from the 14th Floor CER.
o Remove approximately one hundred seventy-six (176) data cables from existing furniture.
o Relocate one hundred eight (108) data cables to new furniture locations.
o Install and terminate relocated cables in new furniture locations.
o Provide labor to relocate existing data cables at five (5) shooting stations.
o Provide and install twenty (20) flush mount single locations.
o Provide and install thirty-two (32) furniture mount dual locations.
o Provide and install six (6) floor box quad locations.
o Provide and install twenty-six (26) flush mount single video wall locations.
o Terminate and test all data cables, including new and old cables.
AV Cabling:
• The following cables will be pulled from the 14th Floor CER.
• Provide and install twelve (12) Belden Low Loss Serial Digital Coax, RG6 single cables and twenty-four (24) coaxial BNC connectors.
• Provide and install six (6) Belden digital microphone 1 pair single cables and twelve (12) 3-pin XLRF connectors.
• Provide and install six (6) Belden microphone cable 2 conductor single cables and twelve (12) 3-pin XLRF connectors.City of Philadelphia · 2026
HORIZONTAL CABLING:
Cabling will be Belden Category 6 plenum rated 4-pair and Belden RG6 quad shield plenum rated coax.
• Provide and install fifty-three (53) flush mount dual Category 6 locations.
• Provide and install one hundred thirty-one (131) furniture mount single Category 6 locations.
• Provide and install fifteen (15) surface mount single Category 6 room scheduler locations. Cables will be dressed down to the device.
• Provide and install twenty-seven (27) surface mount single Category 6 CCTV locations.
• Provide and install two (2) floor mount dual Category 6 locations.
• Provide and install four (4) floor mount triple Category 6 locations.
• Provide and install eighteen (18) floor mount quad Category 6 locations.
• Provide and install six (6) flush mount single coax TV locations.
• Provide and install five (5) single Category 6 wall phone locations.
• Provide and install sixty-three (63) flush mount single Category 6 locations.
• Provide and install Belden faceplates, surface mount boxes, floor frames, modular jacks, couplers and connectors as required for termination of the 4-pair and coax cables at the workstation location.
• Provide and install four (4) Belden Category 6 24-port flat patch panels and eleven (11) Belden Category 6 48-port flat patch panels, each with one (1) strain relief bar. These will be installed at the appropriate closet location for termination of the 4-pair cables installed.
• The coax cables will be terminated and left coiled at the closet location for final connection by others.
• Provide and install two hundred eighteen (218) Belden Category 6 patch cords, blue in color, 5’ in length (IDF).
• Provide and install two hundred eighteen (218) Belden Category 6 patch cords, blue in color, 7’ in length (IDF).
• Provide and install four hundred thirty-five (435) Belden Category 6 patch cords, black in color, 7’ in length (WAO).
WIRELESS ACCESS POINT CABLING:
Cabling will be Belden Category 6A shieldCity of Philadelphia · 2026
HORIZONTAL CABLING:
Cabling will be Berk-Tek LANmark 2000 Category 6 plenum rated 4-pair.
• Provide labor to demo existing low voltage infrastructure and security devices from work space.
• Provide and install six (6) flush mount single locations.
• Provide and install four (4) surface mount single camera locations.
• Provide and install one (1) surface mount single pneumatic tube location.
• Provide and install eleven (11) flush mount dual locations.
• Provide and install one (1) dual wireless access point location.
• Provide labor to remove and reinstall one (1) wireless access point.
• Provide and install one (1) fixed-lens bi-directional camera.
• Provide and install three (3) 180° field-of-view cameras.
• Provide and install one (1) Aiphone door station.
• Provide and install one (1) Aiphone master station.
• Provide and install Siemens faceplates, surface mount boxes, modular jacks and plugs as required for termination of the 4-pair cables at the workstation location.
• Provide labor to terminate cables onto existing hardware at the closet location.
ACCESS CONTROL CABLING:
• Provide labor to remove, relocate and reinstall one (1) existing request to exit device.
• Provide labor to remove one (1) existing card reader and replace with a wave plate.
• Provide and install Belden composite cable as required to the device. Cable will be dressed to the device and terminated at the device and Head End locations-2017 NEC.City of Philadelphia · 2025
Fiber Optic Scope of Work
• Provide labor and material to install nine (9) 20x20x8” junction boxes w/ backboard and heater units at locations shown on provided prints.
• Provide labor and material to install one (1) 06-strand single mode fiber optic cable between ten (10) communication points shown on the provided prints.
• Provide labor and material to install fiber optic housings w/ 12-port LC single mode coupler panels at each location.
• Provide labor to prep 06-strand fiber optic cables and fusion splice LC style fuse on connectors at each location.
• Provide labor to bi-directionally OTDR and power meter all terminated fibers at both 1310 and 1550nm.
• Provide labor properly label all fiber housings.
Cat6 Scope of Work
• Provide labor and material to install one (1) Cat6 OSP rated cable from Communication JB to each of forty-three (43) customer provided cameras.
• Provide labor and material to terminate both ends of the Cat6 cables with RJ45 style connectors.
• Provide labor to perform a Cat6 certification test.
Electrical Scope of Work
• Provide labor and material to install nine (9) 2” EMT conduit at Communications JB mounted on the exterior of the builds.
• Provide labor and material to install nine (9) 20amp circuits w/ quad outlet mounted in JB.
• 20”x20”x8 Network JB will be installed on the exterior of an existing building. 20am quad outlet will be installed inside JB. 3/4" EMT conduit will connect the JB to an existing electrical panel located on the same side of the existing building.
.
Camera Installation
• Provide labor to install forty-three (43) customer provided cameras according to the provided prints.
• Provide labor to make a one times adjustment at each camera location.City of Philadelphia · 2025