What the public permit record shows, not self-reported reviews.
Is ADVANCE MANAGEMENT CORP a real contractor?
ADVANCE MANAGEMENT CORP appears in public building-permit records with 248 permits filed through 2025 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is ADVANCE MANAGEMENT CORP's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to ADVANCE MANAGEMENT CORP by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is ADVANCE MANAGEMENT CORP licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. ADVANCE MANAGEMENT CORP has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is ADVANCE MANAGEMENT CORP's work?
The most recent permit on record for ADVANCE MANAGEMENT CORP is dated 2025-10-02, with 248 permits on file in total.
Fire Suppression System Permit for combo CP-2025-004438City of Philadelphia · 2025
FOR TIE-IN TO EXISTING 8-INCH FIRE SERVICE LINE AND FOR INSTALLATION OF AN 8-INCH BACKFLOW PREVENTER, FIRE PUMP AND FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS, NFPA 13 AND NFPA 20.City of Philadelphia · 2025
INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING (LOT 16) TO INCLUDE 10" MAIN FIRE SERVICE LINE WITH A 10" WATTS 957 BACKFLOW PREVENTION ASSEMBLY (LOCATED IN EXTERIOR HOTBOX) AND UL LISTED PENTAIR 6-481-18B FIRE PUMP COMPLYING WITH NFPA 20 AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.City of Philadelphia · 2025
FOR THE INSTALLATION OF 268 NEW PENDENT SPRINKLERS TO AN EXISTING FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING. AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS.City of Philadelphia · 2025
FOR THE INSTALLATION OF A 10-INCH FIRE SERVICE LINE FOR AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH A BACKFLOW PREVENTION ASSEMBLY AND FIRE PUMP IN ACCORDANCE WITH NFPA 13 & 20. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS.
AMENDMENT 5/6/25 TO CORRECT PERMIT LANGUAGE: FOR AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH A BACKFLOW PREVENTION ASSEMBLY AND FIRE PUMP IN ACCORDANCE WITH NFPA 13 & 20. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS. **SEPARATE PERMIT REQUIRED FOR FIRE SERVICE LINE.**City of Philadelphia · 2024
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you ADVANCE MANAGEMENT CORP?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to ADVANCE MANAGEMENT CORP's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
FOR AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH A FIRE PUMP IN ACCORDANCE WITH NFPA 13 & 20. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS.City of Philadelphia · 2023
EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans.
Relocate 12 sprinkler headsCity of Philadelphia · 2023
EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans.
Relocate 10 existing sprinkler heads for new ceilingCity of Philadelphia · 2023
TO REPLACE A HYDRANT AT A PRIVATE PROPERTY.City of Philadelphia · 2023
For installation of dry sprinkler systems per NFPA 13 in new freezer warehouse with 8-inch fire service line and BFP device as per approved plans. Fire pump to be installed per NFPA 20.City of Philadelphia · 2023
EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans.
RELOCATE 30 HEADSCity of Philadelphia · 2023
FOR THE INSTALLATION OF 230 NEW UPRIGHT/ SIDEWALL SPRINKLERS COMPLYING WITH NFPA 13 TO AN EXISTING FIRE SUPPRESSION SYSTEM AND TWO (2) STANDPIPES COMPLYING WITH NFPA 14 FOR FLOORS 0-3; STANDPIPES TO BE INTERCONNECTED PER NFPA 14 AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS.City of Philadelphia · 2022
Permitted projects on public record. Addresses are omitted for privacy.