What the public permit record shows, not self-reported reviews.
Is ACHIEVE MANAGEMENT INC a real contractor?
ACHIEVE MANAGEMENT INC appears in public building-permit records with 6 permits filed through 2018 in and around City of Philadelphia, PA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is ACHIEVE MANAGEMENT INC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to ACHIEVE MANAGEMENT INC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is ACHIEVE MANAGEMENT INC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. ACHIEVE MANAGEMENT INC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is ACHIEVE MANAGEMENT INC's work?
The most recent permit on record for ACHIEVE MANAGEMENT INC is dated 2018-02-14, with 6 permits on file in total.
MAKE SAFE PERMIT - PERMIT APPLICATION IN RESPONSE TO UNSAFE VIOLATION(S) AS PER CASE # 617968. TO COMPLY VIOLATION(S), COMPLETED WORK IS TO BE INSPECTED AND APPROVED AS AN APPROPRIATE REPAIR TO EACH VIOLATION, NO ENGINEER'S REPORT SUBMITTED. LICENSED CONTRACTOR TO ASSUME RESPONSIBILITY OF WORK. EXTERIOR EAST SIDE WALL - REMOVE LOOSE AND BULGING STUCCO, REPAIR CRACKS AND SEAL. PLEASE CALL THE INSPECTOR AT LEAST 24 HOURS PRIOR TO THE START OF WORK. PROVIDE THE INSPECTOR WITH THE ENGINEER'S FACADE REPORT. EXTERIOR STUCCO WALL COVERING PERMIT REQUIRED TO INSTALL NEW STUCCO & MURAL.City of Philadelphia · 2018
TEMPORARY CETRFICATE OF OCCUPANCYCity of Philadelphia · 2017
MAKE SAFE PERMIT - FOR THE RELOCATION OF TWO EXTERIOR RAIN CONDUCTORS TO THE INTERIOR TO RESOLVE CASE #566201. SEPARATE STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CASE #566201.City of Philadelphia · 2017
FOR THE REMOVAL OF TWO (2) WINDOWS AND THE REPLACEMENT WITH EGRESS WELLS. THE EXISTING LINTEL IN THE MASONRY WALL WILL BE USED FOR THE OPENING. NO CHANGE IN HEIGHT, AREA OR USE OF THE STRUCTURE. ALL WORK PER PLANS APPROVED BY PHILADELPHIA HISTORICAL COMMISSION (NO CHANGE TO FRONT OF STRUCTURE). STRUCTURE FOR USE AS MULTI-FAMILY HOUSEHOLD LIVING [SIX (6) DWELLING UNITS] AS PREVIOUSLY APPROVED.City of Philadelphia · 2016
LEGILZE REPAIRES MMADE TO FRONT RETAINING WALL. STEPS, AND PORCH. NO STRUCTURAL WORK PERFORMED TO PORCHCity of Philadelphia · 2016
NEW CONSTRUCTION OF ADDITIONS AND FIT OUTS. INTERIOR AND EXTERIOR CONSTRUCTION TO INCLUDE ASSOCIATED REMOVING PORTIONS OF EXTERIOR WALL AND STABILIZING, PARTIAL REMOVAL OF EXISTING PORTION AND CONSTRUCTING NEW WALLS FOR NEW 2 STORY ADDITION OVER AND EXISTING (2) STORY STRUCTURE AND NEW 4 STORY ADDITION STRUCTURE. SEE ENGINEERS REPORT ON EXISTING STRUCTURE AND STABILITY. SEE ALSO MAKE SAFE PERMIT FOR ASSOCIATED REMOVALS, DEMO,REHAB ISSUED AND COMPLETED. ASSOCIATED ALTERATIONS AND STRUCTURAL WORK AND FRAMING, MODIFICATIONS,AND FOUNDATION WORK TO INCLUDE UNDERPINNING OF ADJACENT AND INTERIOR FOUNDATION PORTIONS WITH SPECIAL INSPECTIONS BY ENGINEER OF RECORD.
MUST PROTECT ADJACENT STRUCTURES AND PEDESTRIAN WALKWAYS. ANY SIDEWALK SHELTER PLATFORMS REQUIRE ADDITIONAL PERMIT WITH ENGINEERED PLANS AND STREETS DEPARTMENT APPROVAL.
ADDITIONAL PERMITS REQ: ELECTRICAL, PLUMBING, HVAC, SPRINKLERS & S.PIPES USE PERMIT & FIT OUT REQUIRED FOR VACANT SPACE 1ST FLOOR, SP INSP AGENCY.
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you ACHIEVE MANAGEMENT INC?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to ACHIEVE MANAGEMENT INC's website. It links to this profile so homeowners can see the public permit record behind your work.