MAKE INTERIOR ALTERATIONS AND ESTABLISH NURSING SCHOOL PER APPROVED PLANS. SEPARATE PLUMBING, HVAC AND ELECTRICAL PERMITS REQUIRED. CERTIFICATE OF OCCUPANCY REQUIRED. SUBMIT SEPARATE PLANS TO FPB FOR ALTERATIONS TO FIRE PROTECTION SYSTEMS.City of Cleveland · 2026$1,067,964
ADDITIONS AND INTERIOR RENOVATION TO AN EXISTING CAMPUS ARENA. STRUCTURAL, PLUMBING, HVAC, ELECTRICAL AND FIRE PROTECTION PERMITS ARE REQUIRED. CERTIFICATE OF OCCUPACY IS REQUIRED.City of Cleveland · 2026$13,776,787
INTERIOR ALTERATION 41,630 SQ FT FOR MEDICAL IMAGING FACILITY PER APPROVED PLANS. PERMITS REQUIRED FOR PLUMBING, HVAC, ELECTRICAL AND FIRE PROTECTION SYSTEMS.City of Cleveland · 2026$10,826,000
Alterations for a restaurant on the ground floor & new wine bar on the lower level (Juliet & UVA). Conditional approval only: Separate approval of outdoor dining & canopy is pending. Electrical, plumbing and HVAC permits are required. Separate submissions required: automatic fire sprinkler sys, fire alarm and detection sys, kitchen hood fire suppression, signage, elevator license, food service license. Water demand at the base of the sprinkler riser, the hazard classification and grease interceptor instructions to be provided to the Building Dept.City of Cleveland · 2026$1,200,000
INTERIOR ALTERATION 21,000 SQ FT 1ST AND 2ND FLOORS - REMOVE NON-STRUCTURAL ITEMS PER APPROVED PLANS.City of Cleveland · 2025$300,000
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
MAKE INTERIOR ALTERATIONS TO 21,582 SF OF OFFICE SPACE IN PART OF THE FIRST AND SECOND FLOORS PER APPROVED PLANS. SEPARATE PLUMBING, HVAC AND ELECTRICAL PERMITS ARE REQUIRED. CERTIFICATE OF OCCUPANCY IS REQUIRED.City of Cleveland · 2025$883,806
PERFORM BUILDING ALTERATIONS TO MULTIPLE LEVELS OF THE KIRTLAND GALLERY OF THE CLEVELAND MUSEUM OF NATURAL HISTORY FOR AN AHU REPLACEMENT. (PHASE 3). ELECTRICAL, PLUMBING AND HVAC PERMITS ARE REQUIRED. A SEPARATE APPLICATION AND CONSTRUCTION DOCUMENTS ARE REQUIRED TO BE SUBMITTED FOR REVIEW AND APPROVAL FOR THE AUTOMATIC FIRE SPRINKLER. SPECIAL INSPECTIONS ARE REQUIRED.City of Cleveland · 2025$4,400,000
MAKE INTERIOR AND SITE ALTERATIONS PER APPROVED PLANS FOR CHANGE OF USE TO CREATE NEW PRIVATE CLUB FOR FOOD AND DRINK CONSUMPTION. SUPPLEMENTAL CONDITIONS APPLY: FIRE OFFICIAL REQUIRES PERMANENT CONTINUOUS 4’-0” STRIPING AND SIGNAGE EVERY 10’-0” STARTING AT BUILDING’S REAR EXIT DOOR, ACROSS ADJACENT PARCELS, AND ENDING AT PUBLIC WAY (MURRAY HILL ROAD). SIGNAGE SHALL READ “PATH OF EGRESS – DO NOT BLOCK - BY ORDER OF CLEVELAND DIVISION OF FIRE"; NO OCCUPANCY WITHOUT RECORDED ACCESS EASEMENT AGREEMENT FOR 4'-0" INGRESS/EGRESS PATH; POST OCCUPANT LOAD PLACARDS IN EACH ASSEMBLY SPACE; PROVIDE PANIC HARDWARE AT EGRESS GATES; MAINTAIN COPIES OF LIFE SAFETY PLANS AT PREMISES FOR OBC 1002.2/IFC 404.2.1 FIRE SAFETY AND EVACUATION PLAN, GROUP A OCCUPANCY. SEPARATE APPLICATION REQUIRED FOR REVIEW AND APPROVAL OF KITCHEN HOOD. SEPARATE REVIEW AND APPROVAL BY HEALTH DEPARTMENT REQUIRED. SEPARATE ELECTRICAL, HVAC, PLUMBING PERMITS REQUIRED. PENETRATIONS OF RATED ASSEMBLIES PROHIBITED. SUBMIT SEPARATE PLANS TO FPB FOR REVIEW AND APPROVAL OF ALTERATIONS OF FIRE PROTECTION SYSTEMS INCLUDING, BUT NOT LIMITED TO, FIRE ALARM SYSTEM AND HOOD SUPPRESSION SYSTEM. MAINTAIN OBC/OEBC CH33 SAFEGUARDS AND OFC CH33 FIRE SAFETY.City of Cleveland · 2025$674,750
CONSTRUCT NEW ADDITION PER APPROVED PLANS. SUPPLEMENTAL CONDITIONS APPLY: COMPLETE SET OF DRAWINGS STAMPED/SEALED BY DESIGN PROFESSIONAL REQUIRED. SEPARATE PLUMBING, HVAC, ELECTRICAL PERMITS REQUIRED. SPECIAL INSPECTIONS REQUIRED. SUBMIT SEPARATE PLANS TO FPB FOR ALTERATIONS TO FIRE PROTECTION SYSTEMS. MAINTAIN OBC CH 33 SAFEGUARDS AND OFC CH 33 FIRE SAFETY. CERTIFICATE OF OCCUPANCY REQUIRED.City of Cleveland · 2025$105,000
MAKE INTERIOR AND EXTERIOR ALTERATIONS PER APPROVED PLANS. SEPARATE PLUMBING, HVAC, ELECTRICAL PERMITS REQUIRED. SPECIAL INSPECTIONS REQUIRED. FIELD INSPECTIONS REQUIRED. SUBMIT FIRE PROTECTION APPLICATIONS TO FPB FOR ALTERATIONS/CHANGES TO FIRE PROTECTION SYSTEMS. MAINTAIN OBC CH33 AND OEBC CH15 SAFGUARDS, AND OFC CH33 FIRE SAFETY. SEPARATE PERMIT APPLICATION REQUIRED FOR REMOVAL OF EXTERIOR CANOPY. NO EXPANSION OR CHANGE OF USE WITH THIS PERMIT.City of Cleveland · 2024$5,759,946
MAKE INTERIOR ALTERATIONS TO PLANETARIUM LEVELS 2 AND 3 PER APPROVED PLANS. SEPARATE PLUMBING, HVAC AND ELECTRICAL PERMITS REQUIRED. SUBMIT SEPARATE PLANS TO FPB FOR FIRE PROTECTION SYSTEMS.City of Cleveland · 2024$1,966,000
ESTABLISH A-3 USE GROUP FOR COMMUNITY ASSEMBLY HALL PER APPROVED PLANS. NO PLUMBING, HVAC, OR ELECTRICAL WORK WITH THIS PERMIT. INSTALLATION OF PANIC HARDWARE AT FRONT AND REAR EXIT DOORS SHALL BE REQUIRED PRIOR TO ANY CERTIFICATE OF OCCUPANCY OF THE BUILDING. CERTIFICATE OF OCCUPANCY REQUIRED.City of Cleveland · 2023$5,000