PERFORM INTERIOR DEMOLITION AND SELECT STRUCTURAL ALTERATIONS FOR PROJECT SCARLET (PHASE APPROVAL ONLY). NO CERTICATE OF OCCUPANCY TO BE ISSUED WITH THIS PERMIT. SPECIAL INSPECTIONS ARE REQUIRED.City of Cleveland · 2025$4,250,000
AlterationCity of Cincinnati · 2025$750,000
AlterationCity of Cincinnati · 2025$6,737,450
MAKE INTERIOR ALTERATIONS TO RECONSTRUCT EXIST ELEVATOR SHAFT AND INSTALL NEW ELEVATOR PER APPROVED PLANS. SEPARATE HVAC, ELECTRICAL AND ELEVATOR PERMITS REQUIRED.City of Cleveland · 2025$30,000
MAKE INTERIOR ALTERATIONS TO VENDOR KIOSKS PER APPROVED PLANS. NO PLUMBING, HVAC, ELECTRICAL, OR STRUCTURAL ALTERATIONS WITH THIS PERMIT. NO EXPANSION OR CHANGE OF USE WITH THIS PERMIT. SEPARATE REVIEW AND APPROVAL BY HEALTH DEPARTMENT REQUIRED. MAINTAIN OBC CH33 SAFEGUARDS AND OFC CH33 FIRE SAFETY. TYPE II HOODS REVIEWED UNDER SEPARATE COVER - REFERENCE B24027391.
REFERENCE B24017306 and B22031451.
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
City of Cleveland · 2025
$18,890
MAKE INTERIOR AND EXTERIOR ALTERATIONS PER APPROVED PLANS TO FIRST FLOOR BAR AND EXTERIOR PLAZA, AND CHANGE OF USE OF BUILDING AT CENTRO VILLA COMPLEX. SEPARATE PLUMBNG, HVAC, ELECTRICAL PERMITS REQUIRED. PENETRATIONS IN RATED ASSEMBLIES PROHIBITED. STORAGE OF HAZARDOUS MATERIALS PROHIBITED. NO EXTERIOR SIGNAGE WITH THIS PERMIT. SEPARATE APPLICATIONS REQUIRED FOR TENANT BUILD-OUTS AND OCCUPANCY OF GROCERY ROOM 109, OFFICE ROOM 121, AND OFFICE ROOM 203 - NO OCCUPANCY OR USE OF THESE SPACES WITH THIS PERMIT. SEPARATE ENCROACHMENT PERMIT REQUIRED FOR, INCLUDING BUT NOT LIMITED TO, BOLLARDS IN RIGHT-OF-WAY. SEPARATE STREET OPENING/OBSTRUCTION PERMIT REQUIRED. SEPARATE APPLICATION REQUIRED FOR REVIEW AND APPROVAL OF FENCE/GATE ACROSS SHARED BUCKEYE COURT. SEPARATE REVIEW AND APPROVAL BY FPB REQUIRED FOR ALTERATIONS TO FIRE PROTECTION SYSTEMS. REFER TO PLAN APPROVAL LETTER FOR SUPPLEMENTAL CONDITIONS. MAINTAIN OBC CH33 SAFEGUARDS AND OFC CH33 FIRE SAFETY. REFERENCE B24027391, B24030404, B24017306, AND B22031451.City of Cleveland · 2025$687,990
INSTALL HOODS PER APPROVED PLANS. SPECIAL INSPECTIONS REQUIRED. SUPPLEMENTAL CONDITIONS APPLY: PLANS SHOW THE INSTALLATION OF TYPE II HOODS. SUBMIT FIRE PROTECTION APPLICATION TO FIRE PREVENTION BUREAU FOR HOOD SUPPRESSION. ENSURE 3 SETS OF STAMPED PLANS INCLUDE ALL RELATIVE OBC AND OMC CITATIONS AS WELL AS CODES AND STANDARDS.
THE ISSUANCE OF A BUILDING PERMIT BY THE DEPARTMENT OF BUILDING AND HOUSING DOES NOT WAIVE THE REQUIREMENT FOR THE REVIEW AND APPROVAL BY THE FPB. PROJECT SHALL MEET OBC 901.2 THRU 901.2.1.2. SUBMIT RESPECTIVE FIRE PERMIT APPLICATIONS WITH PLANS FOR FIRE PROTECTION (HOOD SUPPRESSION, FIRE ALARM, OTHER SUPPRESSION) TO FIRE PREVENTION BUREAU FOR APPROVAL. BUILDING PERMIT AND DUCT INSPECTION REQUIRED. CONTACT BUILDING AND HOUSING TO SCHEDULE HVAC INSPECTION. CONTACT FIRE PREVENTION BUREAU TO SCHEDULE HOOD SUPPRESSION INSPECTION AND WITNESS TEST.
NO EXPANSION OR CHANGE OF USE WITH THIS PERMIT. SEPARATE REVIEW AND APPROVAL BY HEALTH DEPARTMENT REQUIRED. MAINTAIN OBC CH33 SAFEGUARDS AND OFC CH33 FIRE SAFETY.
REFERENCE B24030404, B24017306 and B22031451.City of Cleveland · 2025$62,215
CONSTRUCT NEW PRE-FAB METAL UTILITY BUILDING PER APPROVED PLANS AND FIELD INSPECTIONS. INSPECTIONS OF FOUNDATIONS AND UNDERGROUND UTILITIES REQUIRED. SPECIAL INSPECTIONS REQUIRED. ELECTRICAL PERMIT REQUIRED. NO PLUMBING, OR HVAC WITH THIS PERMIT. NO STORAGE OF HAZARDOUS MATERIALS OR COMMERCIAL VEHICLES. PHASED APPROVAL ONLY. MAINTAIN OBC CH33 SAFEGUARDS AND OFC CH33 FIRE SAFETY. SEPARATE REVIEW AND APPROVAL BY FIRE PLANS EXAMINER AND FIRE PROTECTION BUREAU REQUIRED.City of Cleveland · 2024$30,000
MAKE INTERIOR AND EXTERIOR ALTERATIONS PER APPROVED PLANS AND FIELD INSPECTIONS FOR CHANGE OF USE (PHASED APPROVAL). SEPARATE HVAC, PLUMBING, ELECTRIC PERMITS REQUIRED. SPECIAL INSPECTIONS REQUIRED. SEPARATE HAZMAT PERMIT REQUIRED – REFER TO PLAN APPROVAL LETTER. NO CIVIL OR SITE WORK WITH THIS PERMIT. STREET OPENING/OBSTRUCTION PERMITS REQUIRED PRIOR TO START OF WORK. SEPARATE REVIEW AND APPROVAL OF WORK IN RIGHT OF WAY REQUIRED. SEPARATE APPLICATION REQUIRED FOR OCCUPANCY AND USE OF GROUND FLOOR TENANT BUILD-OUT. SEPARATE APPLICATION REQUIRED FOR REVIEW AND APPROVAL OF ELEVATORS/FIRE SERVICE ACCESS ELEVATOR. MAINTAIN 2-HR RATING AT SHAFT ENCLOSURES. SUBMIT SEPARATE PLANS TO FPB FOR ALTERATIONS TO FIRE PROTECTION SYSTEMS. REFERENCE B23013883 FOR ADDITIONAL SCOPE OF WORK AT STAIRWAY ENCLOSURE AND MISC WORK.
THE ISSUANCE OF A BUILDING PERMIT BY THE DEPARTMENT OF BUILDING AND HOUSING DOES NOT WAIVE THE REQUIREMENT FOR THE REVIEW AND APPROVAL BY THE FPB. SUPPLEMENTAL CONDITIONS APPLY – REFER TO PLAN APPROVAL LETTER FOR CONDITIONS. MAINTAIN OBC CH33 SAFEGUARDS AND OFC CH33 FIRE SAFETY.City of Cleveland · 2024$21,000,000
MAKE INTERIOR ALTERATIONS PER APPROVED PLANS AND FIELD INSPECTIONS (PHASED APPROVAL). SPECIAL INSPECTIONS REQUIRED. SEPARATE ELECTRICAL AND PLUMBING PERMITS REQUIRED. NO HVAC WITH THIS PERMIT. SUBMIT SEPARATE PLANS TO FPB FOR ALTERATIONS TO FIRE PROTECTION SYSTEMS. SEPARATE APPLICATIONS REQUIRED FOR REVIEW AND APPROVAL OF ALL COMMERICIAL HOODS. MAINTAIN OBC CH33 AND OFC CH33 FIRE SAFETY. NO OCCUPANY OR USE WITH THIS PERMIT. REFERENCE B22031451.City of Cleveland · 2024$1,100,000
Permitted projects on public record. Addresses are omitted for privacy.