Is GAITAUD CONSTRUCTION DESIGN AND DEVELOPMENT CORP legit?
What the public permit record shows, not self-reported reviews.
Is GAITAUD CONSTRUCTION DESIGN AND DEVELOPMENT CORP a real contractor?
GAITAUD CONSTRUCTION DESIGN AND DEVELOPMENT CORP appears in public building-permit records with 7 permits filed through 2023 in and around San Diego County, CA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is GAITAUD CONSTRUCTION DESIGN AND DEVELOPMENT CORP's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to GAITAUD CONSTRUCTION DESIGN AND DEVELOPMENT CORP by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is GAITAUD CONSTRUCTION DESIGN AND DEVELOPMENT CORP licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. GAITAUD CONSTRUCTION DESIGN AND DEVELOPMENT CORP has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is GAITAUD CONSTRUCTION DESIGN AND DEVELOPMENT CORP's work?
The most recent permit on record for GAITAUD CONSTRUCTION DESIGN AND DEVELOPMENT CORP is dated 2023-03-22, with 7 permits on file in total.
Cross street: OLD CASTLE ROAD
Foundation: SLAB
Description of Work: 3830 SQ FT SFD W/ 892 SQ FT ATTACHED GARAGE, 1976 SQ FT DETACHED AIRPLANE HANGER/STORAGE, 200A MSP, TEMP POWER
Notice to Permittee: Temp power shall be inspected prior to framing inspectionSan Diego County · 2023
Cross street: DETRICK WY Foundation: RAISED
Description of Work: 1864 SQFT SFD W/ 484 SQFT DET GARAGE, 1425 SQFT COUNTY STANDARD RET WALL (287 LF, MAX HEIGHT 5') (SLOPING BACKFILL) 200 AMP MSP, TEMP POWER
Notice to Permittee: Temp power shall be inspected prior to framing inspection
12-21-18 PLAN CHANGE: SEE COA TLH
5-13-2019 REFUND REQUEST PROCESSED SEE CONDITIONS OF APPROVAL FOR DETAILS - AWSan Diego County · 2019
Cross street: GRACILIOR DR Foundation: SLAB
Description of Work: 1285 SQFT SFD W/ 606 SQFT ATT GARAGE W/ ROOF MOUNT SOLAR ABOVE W/ BATTERY BACKUP (OFF GRID SYSTEM)
02-06-19 PLAN CHANGE: SEE COA ...TLHSan Diego County · 2019
Cross street: GRACILIOR DR Foundation: SLAB
Description of Work: **FICO**MINOR GRADING FOR PDS2018-RESPRI-000109 (1020 SQ FT 2 STY SFD W/397 SQ FT ATT ADU, 63 SQ FT STAIRWAY, 34 SQ FT DECK & 624 SQ FT ATT GARAGE. 225 AMP ELECT PANEL)San Diego County · 2019
Cross street: tamera rd.
Description of Work: misc stucco worj and 24" wide step for door entery way
*Your project may need to comply with COOL ROOF requirements based on the 2008 Building Energy Efficiency Standards. Products required to comply must be labeled by the Cool Roof Rating council (CRRC), listed in the CRRC's Rated Product Directory (www.coolroofs.org), and tested for solar reflectance and thermal emittance. Your Building Inspector will check for compliance at inspection.
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you GAITAUD CONSTRUCTION DESIGN AND DEVELOPMENT CORP?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to GAITAUD CONSTRUCTION DESIGN AND DEVELOPMENT CORP's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
San Diego County · 2013
Cross street: CAMINO DE ARRIBA
Description of Work: 1680 SQ FT ENG RETAINING WALL PLUS 600 SQ FT CTY STD RETAINING WALL.
(for grading 1026-20070096 w/1001-20070492 - 6410 sq ft two-story SFD, AC & FS, 646 att fin garage & 264 detached fin garage, 460 sq ft balcony terrace, 810 sq ft covered porch).
11-18-16: PERMIT RENEWED @ 25% OF CURRENT FEES...MUST CALL FOR A VALID INSPECTION WITHIN 180 DAYS TO KEEP PERMIT ACTIVE. CDC
11-05-15 PERMIT RENEWED @ 25% OF CURRENT FEES...MUST CALL FOR A VALID INSPECTION WITHIN 180 DAYS...TLHSan Diego County · 2007
Cross street: 4 Gee Rd Foundation: SLAB
Description of Work: 4732 sqft 2-story SFD, 1339 sqft attached garage, 896 sqft cover patio, 145 sqft porch entry, 1555 sqft decks, 152 sqft outdoor kitchen. 300 amp service and temp power permanent base
Notice to Permittee: Temp power shall be inspected prior to framing inspection
12/31/15: PACKET PURGED...VMTSan Diego County · 2013