What the public permit record shows, not self-reported reviews.
Is A 2 M CONTRACTORS INC a real contractor?
A 2 M CONTRACTORS INC appears in public building-permit records with 5 permits filed through 2023 in and around San Diego County, CA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is A 2 M CONTRACTORS INC's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to A 2 M CONTRACTORS INC by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is A 2 M CONTRACTORS INC licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. A 2 M CONTRACTORS INC has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is A 2 M CONTRACTORS INC's work?
The most recent permit on record for A 2 M CONTRACTORS INC is dated 2023-02-03, with 5 permits on file in total.
Cross street: E VISTA WAY Foundation: SLAB
Description of Work: 1196 SQFT DET. ADU, 360 SQFT CNTY STD RET WALL (65 LF BY 4 FT MAX HEIGHT) FOR EXISTING SFD
11/09/2022 - Plan check extended via script by Amy CarrollSan Diego County · 2023
Cross street: CARVALOS DR Foundation: RAISED
Description of Work: 1033 SQFT DET ADU W/ 200 AMP MSP FOR EXISTING SFDSan Diego County · 2021
Cross street: Chase Ave
Description of Work: 4684 sq ft reroof for existing sfd
If a re-roof project is proposed, the following specifications apply.
Existing roofing material: Asphalt Shingles
Proposed roofing material: Ashpalt Shingles
Manufacturer: Owens Corning
Brand and model: TruDefinition Duration
Color (if cool roof required): Amber, CRRC Product ID #0890-0009
Built-up roofing assembly system number per attached listing report (if applicable):
Specific exemption from cool roof requirements (if applicable): yes
Required building inspector field verification* (if applicable):
replace roof sheathing as required
*Note: Self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector.San Diego County · 2017
Cross street: JAMACHA BLVD
Description of Work: 2000 SF RE-ROOF (HRA)
If a re-roof project is proposed, the following specifications apply.
Existing roofing material: ASPHALT SHINGLES
Proposed roofing material: ASPHALT SHINGLES
Manufacturer: OWENS CORNING
Brand and model: TRUDEF DURATION
Color (if cool roof required): SHASTA WHITE CRRC PRODUCT ID # 0890-0008
Built-up roofing assembly system number per attached listing report (if applicable): NO
Specific exemption from cool roof requirements (if applicable): NO
Required building inspector field verification* (if applicable): YES OLD ROOF TEAR OFF
*Note: Self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector.San Diego County · 2016
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you A 2 M CONTRACTORS INC?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add this Permit-Verified badge to A 2 M CONTRACTORS INC's website. It links to this profile so homeowners can see the public permit record behind your work.
Track record sourced from public building-permit records. Figures reflect permitted projects, not self-reported work. Listed on Proven Pros.
Cross street: JULIAN AVENUE
Description of Work: 2600SF REROOF FOR EXISTING SFD.
If a re-roof project is proposed, the following specifications apply.
Existing roofing material: SHINGLES
Proposed roofing material: SHINGLES
Manufacturer: OWENS CORNING
Brand and model: OAKRIDGE SHASTA WHITE
Color (if cool roof REQUIRED: BRIGHT WHITE
Built-up roofing assembly system number per attached listing report (if applicable): NA
Specific exemption from cool roof requirements (if applicable): NA
Required building inspector field verification* (if applicable): NA
*Note: Self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector.San Diego County · 2016
Permitted projects on public record. Addresses are omitted for privacy.