What the public permit record shows, not self-reported reviews.
Is JASON K BRUCE a real contractor?
JASON K BRUCE appears in public building-permit records with 2 permits filed through 2025 in and around Sacramento County, CA. Permits are filed with local government before work begins, so this is a matter of public record, not a self-reported listing.
How is JASON K BRUCE's track record verified?
Every figure on this page comes from building permits pulled from municipal records and matched to JASON K BRUCE by the contractor name on each permit. Permit records cannot be purchased or faked the way online reviews can, which makes them a stronger signal of real, completed work.
Is JASON K BRUCE licensed and insured?
This profile is built from permit records, which confirm permitted work but do not include license status. JASON K BRUCE has not claimed this profile to add license or insurance details. Confirm licensing directly with your state or local board before hiring.
How recent is JASON K BRUCE's work?
The most recent permit on record for JASON K BRUCE is dated 2025-03-15, with 2 permits on file in total.
To support the replacement Filter Dryer (FD-405) the following support modifications will be done.
ARCHITECTURAL:
- INSTALL DOORS AND HARDWARE IN EXISITNG, MODIFIED, OR NEW OPENINGS.
- INSTALL NON-COMBUSTIBLE PARTITION WALLS AS REQUIRED.
- MODIFY EXISTING T-BAR CEILING FOR NEW LAYOUT.
- INSTALL MAINTENANCE DURABLE FINISHES TO ALL SURFACES.
- INSTALL EPOXY FLOORING WITH INTEGRAL COVE BASE.
STRUCTURAL:
- TRENCH AND PATCH-BACK CONCRETE SLAB ON GRADE AS REQUIRED FOR NEW FOOTING AND UTILITIES.
- INFILL ABANDONED HOLES IN EXISTING CONCRETE WALLS AND PROVIDE STRUCTURAL REINFORCING AT NEW WORK.
- INSTALL STRUCTURAL STEEL SUPPORT FRAME FOR NEW EQUIPMENT.
MECHANICAL:
- MODIFY EXISTING DUCTWORK FOR NEW AIRLOCK AND MISTING ROOMS.
- REPLACE EXISTING 95% FILTER WITH NEW 99.99% HEPA FILTER.
- AIR BALANCE.
PLUMBING - BUILDING:
- CONNECT NEW FLOOR DRAIN IN AIR LOCK TO EXISTING PROCESS WASTE LINE.
- CONNECT NEW FLOOR SUMP DRAIN IN MISTING ROOM TO EXISTING PROCESS WASTE LINE.
- CONNECT VENTS FROM NEW DRAINS TO EXISTING PROCESS VENT.
ELECTRICAL:
-INSTALL POWER AND CONNECTIONS FOR ALL EQUIPMENT INCLUDING NEW PANELS WITH BREAKERS.
-INSTALL POWER FOR HOUSE KEEPING RECEPTACLES.
-INSTALL CONDUIT AND CABLEWAY SYSTEMS FOR ALL ELECTRICAL UTILITIES.
-INSTALL LIGHT FIXTURES WITH CONTROL CIRCUITING.
FIRE PROTECTION:
-INSTALL GENERAL FIRE SPRINKLER SYSTEM FOR SPACE COVERAGE AND TO AGGUMENT FIRE RATINGS AS REQUIRED. CONNECTED TO EXISTING FIRE WATER MAIN LOCATED ON UTILITIES RACK ADJACENT THIS BUILDING.
- INSTALL DELUGE FIRE PROTECTION SYSTEM AT EQUIPMENT.
CONTROLS:
- INSTALL ALL OPERATIONS AND MONITORING PANELS AND EQUIPMENT FOR SELECTED EQUIPMENT.
- UTILIZE PATHWAYS INSTALLED UNDER ELECTRICAL WORK FOR ROUTING.
PLUMBING - OPERATIONS:
- INSTALL ALL EQUIPMENT RELATED PIPING INCLUDING SUPPORTS AND FINAL CONNECTIONS TO EQUIPMENT.
- INSTALL OPERATION EQUIPMENT ONTO SUPPORTS PROVIDED BY STRUCTURAL. MAKE FINAL ANCHORAGE CONNECTIONSSacramento County · 2025$2,900,000
1. REPLACEMENT OF EXISTING CN-165 CENTRIFUGE WITH NEW HEINKLE CENTRIFUGE
IN THE SOUTHWEST CORNER OF BUILDING 05-002, Including the necessary changes to support this new piece of equipment.
2. INSTALL NEW AIRLOCK ROOM AND DISCHARGE ROOM IN PLACE OF EXISTNG AIRLOCK AND DISCHARGE ON THE GROUND FLOOR. INSTALL NEW CENTRIFUGE ROOM WITH NEW SUPPORTING STRUCTURAL STEEL FRAMING ABOVE THE DISCHARGE / AIRLOCK ROOMS. INSTALL NEW DOORS FOR EGRESS AND MAINTENANCE ACCESS TO EACH NEW ROOM. 2.D. INSTALL NEW EXIT STAIRWAYS AT 2 LOCATIONS FROM CENTRIFUGE ROOM TO GROUND LEVEL.
3.EXPAND CONCRETE SLAB ON GRADE AND CONCRETE RETENTION CURBS TO ACCOMIDATE NEW GROUND FLOOR LAYOUT. INSTALL NEW STRUCTRUAL STEEL FRAMEING TO RESUPPORT EXISTING ADJACENT PLATFORMS AND THE FLOOR AREA OF THE NEW MAINTENANCE PLATFORM FOR THE CENTRIFUGE ROOM. INSTALL NEW CONCRETE FILLED METAL DECK FLOORING FOR THE CENTRIFUGE ROOM. INSTALL NEW STAIRCASE FROM CENTRIFUGE ROOM INCLUDING UPPER
LANDING WITH REMOVABLE RAILING FOR EQUIPMENT ACCESS.
4.REPLACE EXISTING AIR HANDLER WITH NEW THAT IS HEPA RATED. MODIFY EXISTNG EXHAUST FANS AND PRIVIDE NEW DUCTWORK TO SUPPORT OPERATIONS IN THE SPACES.
5. INSTALL POWER AND CONNECTIONS FOR ALL EQUIPMENT CONNECTED TO EXISTING PANEL CIRCUITS. INSTALL POWER FOR HOUSE KEEPING RECEPTACLES. INSTALL CONDUIT AND CABLEWAY SYSTEMS FOR ALL ELECTRICAL UTILITIES. INSTALL LIGHT FIXTURES WITH CONTROL CIRCUITING.
6. INSTALL GENERAL FIRE SPRINKLER SYSTEM FOR SPACE COVERAGE. CONNECT TO EXISTING FIRE WATER MAIN LOCATED UNDER ROOF ADJACENT THIS SPACE. INSTALL DELUGE FIRE PROTECTION SYSTEM AT EQUIPMENT.
7. INSTALL ALL OPERATIONS AND MONITORING PANELS AND EQUIPMENT FOR SELECTED EQUIPMENT. UTILIZE PATHWAYS INSTALLED UNDER ELECTRICAL WORK FOR ROUTING.
8. INSTALL ALL EQUIPMENT RELATED PIPING INCLUDING SUPPORTS AND FINAL CONNECTIONS TO EQUIPMENT. INSTALL OPERATION EQUIPMENT ONTO SUPPORTS PROVIDED BY STRUCTURAL. MAKE FINAL ANCHORAGE CONNECTIONS.
Republishing these numbers? A link back is all we ask — one click copies a ready credit you can paste into any post.
Are you JASON K BRUCE?
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.