Add new 60 amp circuit and run approximately 35’ 6 AWG wire in ¾” EMT & FMC
conduit with 10 AWG ground to new Rivian for EV charging. Charger uses 48 Amps.Sacramento County · 2026$1,415
Add new 30 amp circuit and run approximately 35’ 8 AWG wire in ¾” EMT conduit
with 10 AWG ground to new Tesla Wall Connector for EV charging. Charger uses 24
Amps.Sacramento County · 2026$1,696
SolarApp ID: SA20260528-2133-204-10787-A; (20) REC SOLAR REC450AA-PURE-RX MODULES·
(20) ENPHASE IQ8X-80-M-US (240V) MICROINVERTERS·
(01) TESLA POWERWALL 3 (11.5KW, 13.5KWH) ·
(01) POWERWALL 3 DC EXPANSION UNIT (13.5KWH) ·
(01) ENERGY SYSTEM DISCONNECT ·
(01) ENPHASE COMBINER BOX 5 ·
(01) TESLA BACKUP SWITCH ·
(01) TESLA REMOTE METER
TOTAL PV SIZE: 9.000 KW DC, 8.282 KW CEC ACSacramento County · 2026$57,701
Electrical service panel replacement or emergency repair only. No additional electrical, mechanical, plumbing, or structural work permitted.; Remove & Replace existing MSP 200 ampSacramento County · 2026$4,135
Electrical service panel replacement or emergency repair only. No additional electrical, mechanical, plumbing, or structural work permitted.; Remove & Replace existing MSP 200 ampSacramento County · 2026$4,355
Add new 60 amp circuit and run approximately 10’ 6 AWG wire in ¾” EMT conduit
with 10 AWG ground to new Tesla Wall Connector for EV charging. Charger uses 48 Amps.
This profile was built from public permit records. Claim it free to add your photo, phone, and website, so the homeowners landing here can actually reach you.
Add new 60 amp circuit and run approximately 35’ 6 AWG wire in ¾” EMT conduit
with 10 AWG ground to new Tesla Wall Connector for EV charging. Charger uses 48 Amps.Sacramento County · 2026$1,341
Add new 60 amp circuit and run approximately 10’ 6 AWG wire in ¾” EMT conduit
with 10 AWG ground to new Emporia for EV charging. Charger uses 48 AmpsSacramento County · 2026$870
Add new 40 amp circuit and run approximately 55’ 8 AWG wire in some existing
and then to new ¾” EMT conduit with 10 AWG ground to new Tesla Wall Connector for
EV charging. Charger uses 32 AmpsSacramento County · 2026$850
Add new 60 amp circuit and run approximately 10’ 6 AWG wire in ¾” EMT conduit
with 10 AWG ground to new Emporia for EV charging. Charger uses 48 Amps.Sacramento County · 2026$1,205
Add new 40 amp circuit and run approximately 10’ 8 AWG wire in ¾” EMT conduit
with 10 AWG ground to new Tesla Wall Connector for EV charging. Charger uses 32
AmpsSacramento County · 2026$795
Add new 60 amp circuit and run approximately 10’ 6 AWG wire in ¾” EMT
conduit with 10 AWG ground to new Emporia for EV charging. Charger uses 48 Amps.Sacramento County · 2026$870
Permitted projects on public record. Addresses are omitted for privacy.